8.8SPJul 9
SpO$_2$ Predictor-Guided Stage-Wise Time-Frequency Reconstruction of Low-Quality Dual-Wavelength PPG for Oxygen Saturation EstimationZequan Liang, Elahe Hosseini, Ning Miao et al.
Continuous oxygen saturation (SpO$_2$) estimation from wearable photoplethysmography (PPG) is important for long-term health monitoring, but low-quality red and infrared PPG segments can distort waveform morphology and degrade SpO$_2$ prediction accuracy. Existing PPG denoising and reconstruction methods usually optimize waveform fidelity or heart rate characteristics, while time-domain waveform loss on PPG signals alone insufficiently preserves frequency structure and SpO$_2$-relevant information. This paper proposes a SpO$_2$ predictor-guided stage-wise time-frequency reconstruction framework for low-quality dual-wavelength PPG signals. The proposed method first selects high-quality PPG segments to pretrain a SpO$_2$ predictor. A masked reconstruction model is then trained to recover randomly masked PPG regions using a joint reconstruction objective that combines time-domain waveform loss with frequency-domain loss computed from the short-time Fourier transform (STFT). To make the reconstruction task physiologically relevant, the pretrained SpO$_2$ predictor is incorporated as an additional constraint, encouraging the reconstructed PPG to preserve SpO$_2$ information rather than only minimizing waveform reconstruction error. The SpO$_2$ predictor and PPG reconstructor model are optimized through four training stages. Experiments on the public OpenOximetry Repository and a private wearable PPG dataset show that the proposed approach achieves the lowest subject-level MAE, with 2.882\% on the public dataset and 2.359\% on the private dataset.
6.8SPJul 9
Unit-Independent Low-Rate Wrist GSR Processing for Stress Detection Using Phasic nSCR FeaturesZequan Liang, Sally Hang, Geneva M. Jost et al.
Galvanic skin response (GSR) is widely used for stress detection, but wrist-based GSR remains challenging because its absolute amplitude can differ substantially from laboratory-grade palmar measurements. In this paper, we propose a unit-independent low-rate wrist GSR processing pipeline to extract the number of skin conductance responses per minute (nSCR/min) as a stress-related feature. We collect paired wrist and palmar GSR recordings from 31 participants during sitting baseline, standing baseline, neutral speaking, and the Trier Social Stress Test (TSST), a laboratory social stressor task. The proposed pipeline cleans the raw GSR signal, decomposes it into tonic skin conductance level (SCL) and phasic skin conductance response (SCR), applies robust z-score normalization, and detects phasic SCR peaks to compute nSCR/min. Using random forest on 25Hz We-Be GSR, nSCR/min achieved balanced accuracies of 0.823 and 0.871 for binary classification between TSST and the sitting and standing baselines, respectively. Moreover, the 25Hz We-Be GSR features achieved comparable balanced accuracy to the original 100Hz features across the evaluated tasks. These results suggest the feasibility of low-rate, unit-independent wrist GSR processing for wearable stress detection.
7.4ETMay 15
Lightweight Cross-Device Sleep Tracking on the WeBe Wearable PlatformWei Shao, Ehsan Kourkchi, Krishi Prashant Shah et al.
Wearable devices are widely used for continuous health monitoring, yet reliable sleep tracking on emerging platforms remains underexplored due to reliance on proprietary algorithms and device-specific activity representations. We present a lightweight and reproducible sleep tracking pipeline that operates directly on raw accelerometer signals. The method converts data into epoch-level activity features, applies temporal smoothing and normalized scoring, and performs sleep/wake classification using a globally calibrated threshold. We calibrate the model on the Multilevel Monitoring of Activity and Sleep in Healthy People (MMASH) dataset and evaluate it in a cross-device study using the WeBe wearable platform and a commercial ActiGraph device. On MMASH, the method achieves a mean absolute error of 41.6 minutes in Total Sleep Time (TST), with onset and offset errors of 6.3 and 7.4 minutes. On real-world WeBe data from three participants across five sessions, it achieves a mean TST error of 27.4 minutes and onset and offset errors of 13.9 and 8.0 minutes. In contrast, a commercial ActiGraph pipeline shows larger discrepancies relative to ground truth. These results demonstrate accurate and generalizable sleep tracking using a simple and reproducible pipeline.
8.6CRAug 19, 2025
Know Me by My Pulse: Toward Practical Continuous Authentication on Wearable Devices via Wrist-Worn PPGWei Shao, Zequan Liang, Ruoyu Zhang et al.
Biometric authentication using physiological signals offers a promising path toward secure and user-friendly access control in wearable devices. While electrocardiogram (ECG) signals have shown high discriminability, their intrusive sensing requirements and discontinuous acquisition limit practicality. Photoplethysmography (PPG), on the other hand, enables continuous, non-intrusive authentication with seamless integration into wrist-worn wearable devices. However, most prior work relies on high-frequency PPG (e.g., 75 - 500 Hz) and complex deep models, which incur significant energy and computational overhead, impeding deployment in power-constrained real-world systems. In this paper, we present the first real-world implementation and evaluation of a continuous authentication system on a smartwatch, We-Be Band, using low-frequency (25 Hz) multi-channel PPG signals. Our method employs a Bi-LSTM with attention mechanism to extract identity-specific features from short (4 s) windows of 4-channel PPG. Through extensive evaluations on both public datasets (PTTPPG) and our We-Be Dataset (26 subjects), we demonstrate strong classification performance with an average test accuracy of 88.11%, macro F1-score of 0.88, False Acceptance Rate (FAR) of 0.48%, False Rejection Rate (FRR) of 11.77%, and Equal Error Rate (EER) of 2.76%. Our 25 Hz system reduces sensor power consumption by 53% compared to 512 Hz and 19% compared to 128 Hz setups without compromising performance. We find that sampling at 25 Hz preserves authentication accuracy, whereas performance drops sharply at 20 Hz while offering only trivial additional power savings, underscoring 25 Hz as the practical lower bound. Additionally, we find that models trained exclusively on resting data fail under motion, while activity-diverse training improves robustness across physiological states.
2.3SPSep 15, 2025
Self-Supervised and Topological Signal-Quality Assessment for Any PPG DeviceWei Shao, Ruoyu Zhang, Zequan Liang et al.
Wearable photoplethysmography (PPG) is embedded in billions of devices, yet its optical waveform is easily corrupted by motion, perfusion loss, and ambient light, jeopardizing downstream cardiometric analytics. Existing signal-quality assessment (SQA) methods rely either on brittle heuristics or on data-hungry supervised models. We introduce the first fully unsupervised SQA pipeline for wrist PPG. Stage 1 trains a contrastive 1-D ResNet-18 on 276 h of raw, unlabeled data from heterogeneous sources (varying in device and sampling frequency), yielding optical-emitter- and motion-invariant embeddings (i.e., the learned representation is stable across differences in LED wavelength, drive intensity, and device optics, as well as wrist motion). Stage 2 converts each 512-D encoder embedding into a 4-D topological signature via persistent homology (PH) and clusters these signatures with HDBSCAN. To produce a binary signal-quality index (SQI), the acceptable PPG signals are represented by the densest cluster while the remaining clusters are assumed to mainly contain poor-quality PPG signals. Without re-tuning, the SQI attains Silhouette, Davies-Bouldin, and Calinski-Harabasz scores of 0.72, 0.34, and 6173, respectively, on a stratified sample of 10,000 windows. In this study, we propose a hybrid self-supervised-learning--topological-data-analysis (SSL--TDA) framework that offers a drop-in, scalable, cross-device quality gate for PPG signals.