Ehab F. El‐Saadany

CR
h-index82
4papers
15citations
Novelty48%
AI Score37

4 Papers

5.9SYSep 6, 2024
Unmasking Covert Intrusions: Detection of Fault-Masking Cyberattacks on Differential Protection Systems

Ahmad Mohammad Saber, Amr Youssef, Davor Svetinovic et al.

Line Current Differential Relays (LCDRs) are high-speed relays progressively used to protect critical transmission lines. However, LCDRs are vulnerable to cyberattacks. Fault-Masking Attacks (FMAs) are stealthy cyberattacks performed by manipulating the remote measurements of the targeted LCDR to disguise faults on the protected line. Hence, they remain undetected by this LCDR. In this paper, we propose a two-module framework to detect FMAs. The first module is a Mismatch Index (MI) developed from the protected transmission line's equivalent physical model. The MI is triggered only if there is a significant mismatch in the LCDR's local and remote measurements while the LCDR itself is untriggered, which indicates an FMA. After the MI is triggered, the second module, a neural network-based classifier, promptly confirms that the triggering event is a physical fault that lies on the line protected by the LCDR before declaring the occurrence of an FMA. The proposed framework is tested using the IEEE 39-bus benchmark system. Our simulation results confirm that the proposed framework can accurately detect FMAs on LCDRs and is not affected by normal system disturbances, variations, or measurement noise. Our experimental results using OPAL-RT's real-time simulator confirm the proposed solution's real-time performance capability.

6.2CRApr 26
An AI-Based Supervisory Measurement Integrity Validation Layer for Cyber-Resilient AC/DC Protection in Inverter-Based Microgrids

Ahmad Mohammad Saber, Ahmed Saber Refae, Davor Svetinovic et al.

Line current differential relays (LCDRs) are measurement-driven relays that rely on time-synchronized multi-phase current waveforms to infer internal faults in AC and DC power networks. In inverter-based microgrids, however, the increasing reliance on digitally communicated measurements exposes LCDRs to false-data injection attacks (FDIAs), in which adversaries manipulate remote measurement streams to create protection-triggering yet physically inconsistent current trajectories. This paper addresses this emerging measurement integrity problem by introducing a measurement integrity validation scheme that operates as a supervisory instrumentation layer for modern LCDRs. The proposed scheme interprets short windows of synchronized instantaneous current measurements recorded during relay operation and assesses their physical consistency to distinguish genuine fault-induced trajectories from cyber-manipulated measurement streams. A recurrent neural network is trained offline using only relay-available current measurements and exploits the temporal structure of differential current waveforms, which remains informative in inverter-dominated systems where current magnitude is no longer a reliable observable. The method requires no additional sensors, auxiliary protection elements, or prior knowledge of network topology, and is applicable to both AC and DC LCDRs without structural modification. The proposed measurement validation scheme is evaluated on an islanded inverter-based microgrid under a comprehensive set of fault and FDIA scenarios, demonstrating high detection accuracy while preserving relay dependability. Hardware-in-the-loop validation using an OPAL-RT real-time simulator confirms that the scheme satisfies protection timing constraints and can operate in real time under realistic operating conditions.

1.2SPAug 16, 2024
A Novel Approach to Classify Power Quality Signals Using Vision Transformers

Ahmad Mohammad Saber, Alaa Selim, Mohamed M. Hammad et al.

With the rapid integration of electronically interfaced renewable energy resources and loads into smart grids, there is increasing interest in power quality disturbances (PQD) classification to enhance the security and efficiency of these grids. This paper introduces a new approach to PQD classification based on the Vision Transformer (ViT) model. When a PQD occurs, the proposed approach first converts the power quality signal into an image and then utilizes a pre-trained ViT to accurately determine the class of the PQD. Unlike most previous works, which were limited to a few disturbance classes or small datasets, the proposed method is trained and tested on a large dataset with 17 disturbance classes. Our experimental results show that the proposed ViT-based approach achieves PQD classification precision and recall of 98.28% and 97.98%, respectively, outperforming recently proposed techniques applied to the same dataset.

6.4LGFeb 22, 2024
Enhancing Power Quality Event Classification with AI Transformer Models

Ahmad Mohammad Saber, Amr Youssef, Davor Svetinovic et al.

Recently, there has been a growing interest in utilizing machine learning for accurate classification of power quality events (PQEs). However, most of these studies are performed assuming an ideal situation, while in reality, we can have measurement noise, DC offset, and variations in the voltage signal's amplitude and frequency. Building on the prior PQE classification works using deep learning, this paper proposes a deep-learning framework that leverages attention-enabled Transformers as a tool to accurately classify PQEs under the aforementioned considerations. The proposed framework can operate directly on the voltage signals with no need for a separate feature extraction or calculation phase. Our results show that the proposed framework outperforms recently proposed learning-based techniques. It can accurately classify PQEs under the aforementioned conditions with an accuracy varying between 99.81%$-$91.43% depending on the signal-to-noise ratio, DC offsets, and variations in the signal amplitude and frequency.