Javier Bisbal

LG
h-index25
3papers
1citation
Novelty52%
AI Score39

3 Papers

24.4LGMar 31
Unsupervised 4D Flow MRI Velocity Enhancement and Unwrapping Using Divergence-Free Neural Networks

Javier Bisbal, Julio Sotelo, Hernán Mella et al.

This work introduces an unsupervised Divergence and Aliasing-Free neural network (DAF-FlowNet) for 4D Flow Magnetic Resonance Imaging (4D Flow MRI) that jointly enhances noisy velocity fields and corrects phase wrapping artifacts. DAF-FlowNet parameterizes velocities as the curl of a vector potential, enforcing mass conservation by construction and avoiding explicit divergence-penalty tuning. A cosine data-consistency loss enables simultaneous denoising and unwrapping from wrapped phase images. On synthetic aortic 4D Flow MRI generated from computational fluid dynamics, DAF-FlowNet achieved lower errors than existing techniques (up to 11% lower velocity normalized root mean square error, 11% lower directional error, and 44% lower divergence relative to the best-performing alternative across noise levels), with robustness to moderate segmentation perturbations. For unwrapping, at peak velocity/velocity-encoding ratios of 1.4 and 2.1, DAF-FlowNet achieved 0.18% and 5.2% residual wrapped voxels, representing reductions of 72% and 18% relative to the best alternative method, respectively. In scenarios with both noise and aliasing, the proposed single-stage formulation outperformed a state-of-the-art sequential pipeline (up to 15% lower velocity normalized root mean square error, 11% lower directional error, and 28% lower divergence). Across 10 hypertrophic cardiomyopathy patient datasets, DAF-FlowNet preserved fine-scale flow features, corrected aliased regions, and improved internal flow consistency, as indicated by reduced inter-plane flow bias in aortic and pulmonary mass-conservation analyses recommended by the 4D Flow MRI consensus guidelines. These results support DAF-FlowNet as a framework that unifies velocity enhancement and phase unwrapping to improve the reliability of cardiovascular 4D Flow MRI.

CVSep 22, 2025
Automated Labeling of Intracranial Arteries with Uncertainty Quantification Using Deep Learning

Javier Bisbal, Patrick Winter, Sebastian Jofre et al.

Accurate anatomical labeling of intracranial arteries is essential for cerebrovascular diagnosis and hemodynamic analysis but remains time-consuming and subject to interoperator variability. We present a deep learning-based framework for automated artery labeling from 3D Time-of-Flight Magnetic Resonance Angiography (3D ToF-MRA) segmentations (n=35), incorporating uncertainty quantification to enhance interpretability and reliability. We evaluated three convolutional neural network architectures: (1) a UNet with residual encoder blocks, reflecting commonly used baselines in vascular labeling; (2) CS-Net, an attention-augmented UNet incorporating channel and spatial attention mechanisms for enhanced curvilinear structure recognition; and (3) nnUNet, a self-configuring framework that automates preprocessing, training, and architectural adaptation based on dataset characteristics. Among these, nnUNet achieved the highest labeling performance (average Dice score: 0.922; average surface distance: 0.387 mm), with improved robustness in anatomically complex vessels. To assess predictive confidence, we implemented test-time augmentation (TTA) and introduced a novel coordinate-guided strategy to reduce interpolation errors during augmented inference. The resulting uncertainty maps reliably indicated regions of anatomical ambiguity, pathological variation, or manual labeling inconsistency. We further validated clinical utility by comparing flow velocities derived from automated and manual labels in co-registered 4D Flow MRI datasets, observing close agreement with no statistically significant differences. Our framework offers a scalable, accurate, and uncertainty-aware solution for automated cerebrovascular labeling, supporting downstream hemodynamic analysis and facilitating clinical integration.

LGMay 31, 2025
Adaptive Plane Reformatting for 4D Flow MRI using Deep Reinforcement Learning

Javier Bisbal, Julio Sotelo, Maria I Valdés et al.

Deep reinforcement learning (DRL) algorithms have shown robust results in plane reformatting tasks. In these methods, an agent sequentially adjusts the position and orientation of an initial plane towards an objective location. This process allows accurate plane reformatting, without the need for detailed landmarks, which makes it suitable for images with limited contrast and resolution, such as 4D flow MRI. However, current DRL methods require the test dataset to be in the same position and orientation as the training dataset. In this paper, we present a novel technique that utilizes a flexible coordinate system based on the current state, enabling navigation in volumes at any position or orientation. We adopted the Asynchronous Advantage Actor Critic (A3C) algorithm for reinforcement learning, outperforming Deep Q Network (DQN). Experimental results in 4D flow MRI demonstrate improved accuracy in plane reformatting angular and distance errors (6.32 +- 4.15 ° and 3.40 +- 2.75 mm), as well as statistically equivalent flow measurements determined by a plane reformatting process done by an expert (p=0.21). The method's flexibility and adaptability make it a promising candidate for other medical imaging applications beyond 4D flow MRI.