Hao Wu

h-index14
2papers
955citations

2 Papers

3.9CVJun 27, 2023
Cardiac CT perfusion imaging of pericoronary adipose tissue (PCAT) highlights potential confounds in coronary CTA

Hao Wu, Yingnan Song, Ammar Hoori et al.

Features of pericoronary adipose tissue (PCAT) assessed from coronary computed tomography angiography (CCTA) are associated with inflammation and cardiovascular risk. As PCAT is vascularly connected with coronary vasculature, the presence of iodine is a potential confounding factor on PCAT HU and textures that has not been adequately investigated. Use dynamic cardiac CT perfusion (CCTP) to inform contrast determinants of PCAT assessment. From CCTP, we analyzed HU dynamics of territory-specific PCAT, myocardium, and other adipose depots in patients with coronary artery disease. HU, blood flow, and radiomics were assessed over time. Changes from peak aorta time, Pa, chosen to model the time of CCTA, were obtained. HU in PCAT increased more than in other adipose depots. The estimated blood flow in PCAT was ~23% of that in the contiguous myocardium. Comparing PCAT distal and proximal to a significant stenosis, we found less enhancement and longer time-to-peak distally. Two-second offsets [before, after] Pa resulted in [ 4-HU, 3-HU] differences in PCAT. Due to changes in HU, the apparent PCAT volume reduced ~15% from the first scan (P1) to Pa using a conventional fat window. Comparing radiomic features over time, 78% of features changed >10% relative to P1. CCTP elucidates blood flow in PCAT and enables analysis of PCAT features over time. PCAT assessments (HU, apparent volume, and radiomics) are sensitive to acquisition timing and the presence of obstructive stenosis, which may confound the interpretation of PCAT in CCTA images. Data normalization may be in order.

6.6CRFeb 4, 2021
LEAP: TrustZone Based Developer-Friendly TEE for Intelligent Mobile Apps

Lizhi Sun, Shuocheng Wang, Hao Wu et al.

ARM TrustZone is widely deployed on commercial-off-the-shelf mobile devices for secure execution. However, many Apps cannot enjoy this feature because it brings many constraints to App developers. Previous works have been proposed to build a secure execution environment for developers on top of TrustZone. Unfortunately, these works are still not fully-fledged solutions for mobile Apps, especially for emerging intelligent Apps. To this end, we propose LEAP, which is a lightweight developer-friendly TEE solution for mobile Apps. LEAP enables isolated codes to execute in parallel and access peripheral (e.g., mobile GPUs) with ease, flexibly manages system resources upon different workloads, and offers the auto DevOps tool to help developers prepare the codes running on it. We implement the LEAP prototype on the off-the-shelf ARM platform and conduct extensive experiments on it. The experimental results show that Apps can be adapted to run with LEAP easily and efficiently. Compared to the state-of-the-art work along this research line, LEAP can achieve an average 3.57x speedup in supporting intelligent Apps using mobile GPU acceleration.