Agis Chartsias

CV
h-index1
3papers
2citations
Novelty45%
AI Score35

3 Papers

4.8IVJul 13, 2022
Left Ventricle Contouring of Apical Three-Chamber Views on 2D Echocardiography

Alberto Gomez, Mihaela Porumb, Angela Mumith et al.

We propose a new method to automatically contour the left ventricle on 2D echocardiographic images. Unlike most existing segmentation methods, which are based on predicting segmentation masks, we focus at predicting the endocardial contour and the key landmark points within this contour (basal points and apex). This provides a representation that is closer to how experts perform manual annotations and hence produce results that are physiologically more plausible. Our proposed method uses a two-headed network based on the U-Net architecture. One head predicts the 7 contour points, and the other head predicts a distance map to the contour. This approach was compared to the U-Net and to a point based approach, achieving performance gains of up to 30\% in terms of landmark localisation (<4.5mm) and distance to the ground truth contour (<3.5mm).

3.6CVNov 2, 2025
Anatomically Constrained Transformers for Echocardiogram Analysis

Alexander Thorley, Agis Chartsias, Jordan Strom et al.

Video transformers have recently demonstrated strong potential for echocardiogram (echo) analysis, leveraging self-supervised pre-training and flexible adaptation across diverse tasks. However, like other models operating on videos, they are prone to learning spurious correlations from non-diagnostic regions such as image backgrounds. To overcome this limitation, we propose the Video Anatomically Constrained Transformer (ViACT), a novel framework that integrates anatomical priors directly into the transformer architecture. ViACT represents a deforming anatomical structure as a point set and encodes both its spatial geometry and corresponding image patches into transformer tokens. During pre-training, ViACT follows a masked autoencoding strategy that masks and reconstructs only anatomical patches, enforcing that representation learning is focused on the anatomical region. The pre-trained model can then be fine-tuned for tasks localized to this region. In this work we focus on the myocardium, demonstrating the framework on echo analysis tasks such as left ventricular ejection fraction (EF) regression and cardiac amyloidosis (CA) detection. The anatomical constraint focuses transformer attention within the myocardium, yielding interpretable attention maps aligned with regions of known CA pathology. Moreover, ViACT generalizes to myocardium point tracking without requiring task-specific components such as correlation volumes used in specialized tracking networks.

3.6CVNov 17, 2025
Self-Supervised Ultrasound Screen Detection

Alberto Gomez, Jorge Oliveira, Ramon Casero et al.

Ultrasound (US) machines display images on a built-in monitor, but routine transfer to hospital systems relies on DICOM. We propose a self-supervised pipeline to extract the US image from a photograph of the monitor. This removes the DICOM bottleneck and enables rapid testing and prototyping of new algorithms. In a proof-of-concept study, the rectified images retained enough visual fidelity to classify cardiac views with a balanced accuracy of 0.79 with respect to the native DICOMs.