Bin Pu

h-index9
2papers
194citations

2 Papers

2.8CVAug 15, 2023Code
Real-time Automatic M-mode Echocardiography Measurement with Panel Attention from Local-to-Global Pixels

Ching-Hsun Tseng, Shao-Ju Chien, Po-Shen Wang et al.

Motion mode (M-mode) recording is an essential part of echocardiography to measure cardiac dimension and function. However, the current diagnosis cannot build an automatic scheme, as there are three fundamental obstructs: Firstly, there is no open dataset available to build the automation for ensuring constant results and bridging M-mode echocardiography with real-time instance segmentation (RIS); Secondly, the examination is involving the time-consuming manual labelling upon M-mode echocardiograms; Thirdly, as objects in echocardiograms occupy a significant portion of pixels, the limited receptive field in existing backbones (e.g., ResNet) composed from multiple convolution layers are inefficient to cover the period of a valve movement. Existing non-local attentions (NL) compromise being unable real-time with a high computation overhead or losing information from a simplified version of the non-local block. Therefore, we proposed RAMEM, a real-time automatic M-mode echocardiography measurement scheme, contributes three aspects to answer the problems: 1) provide MEIS, a dataset of M-mode echocardiograms for instance segmentation, to enable consistent results and support the development of an automatic scheme; 2) propose panel attention, local-to-global efficient attention by pixel-unshuffling, embedding with updated UPANets V2 in a RIS scheme toward big object detection with global receptive field; 3) develop and implement AMEM, an efficient algorithm of automatic M-mode echocardiography measurement enabling fast and accurate automatic labelling among diagnosis. The experimental results show that RAMEM surpasses existing RIS backbones (with non-local attention) in PASCAL 2012 SBD and human performances in real-time MEIS tested. The code of MEIS and dataset are available at https://github.com/hanktseng131415go/RAME.

33.2CVOct 9, 2025Code
Hulu-Med: A Transparent Generalist Model towards Holistic Medical Vision-Language Understanding

Songtao Jiang, Yuan Wang, Sibo Song et al.

Real-world clinical decision-making requires integrating heterogeneous data, including medical text, 2D images, 3D volumes, and videos, while existing AI systems fail to unify all these signals, limiting their utility. In this paper, we introduce Hulu-Med, a transparent, generalist medical Vision-Language Model (VLM) designed to unify language-only, 2D/3D vision-language, and video understanding within a single architecture. Hulu-Med is trained on a curated corpus of 16.7 million samples, comprising exclusively public or synthetic data, spanning 12 major anatomical systems and 14 medical imaging modalities. Hulu-Med employs a medical-aware token-reduction strategy that prunes redundant visual tokens, achieving up to a 55% reduction for 3D and video inputs, improving cross-modal efficiency, and enabling training at 7B-32B parameter scales in approximately 4,000-40,000 GPU hours. Across 30 public in-domain and out-of-domain medical benchmarks-covering text reasoning, visual question answering, report generation, multilingual dialogue, video understanding, and rare disease diagnosis-Hulu-Med surpasses existing open-source models on 27 of 30 benchmarks and outperforms proprietary systems such as GPT-4o on 16 benchmarks. Despite being a VLM, Hulu-Med outperforms GPT-4o and matches GPT-o1 on the text-only HealthBench. For the first time in the community, we provide a fully transparent, reproducible and cost-effective pipeline for holistic medical vision-language understanding by releasing our end-to-end data curation, training procedures, and model parameters. Code and models are available at https://github.com/ZJUI-AI4H/Hulu-Med.