58.9ROMar 24
ProbeMDE: Uncertainty-Guided Active Proprioception for Monocular Depth Estimation in Surgical RoboticsBritton Jordan, Jordan Thompson, Jesse F. d'Almeida et al.
Monocular depth estimation (MDE) provides a useful tool for robotic perception, but its predictions are often uncertain and inaccurate in challenging environments such as surgical scenes where textureless surfaces, specular reflections, and occlusions are common. To address this, we propose ProbeMDE, a cost-aware active sensing framework that combines RGB images with sparse proprioceptive measurements for MDE. Our approach utilizes an ensemble of MDE models to predict dense depth maps conditioned on both RGB images and on a sparse set of known depth measurements obtained via proprioception, where the robot has touched the environment in a known configuration. We quantify predictive uncertainty via the ensemble's variance and measure the gradient of the uncertainty with respect to candidate measurement locations. To prevent mode collapse while selecting maximally informative locations to propriocept (touch), we leverage Stein Variational Gradient Descent (SVGD) over this gradient map. We validate our method in both simulated and physical experiments on central airway obstruction surgical phantoms. Our results demonstrate that our approach outperforms baseline methods across standard depth estimation metrics, achieving higher accuracy while minimizing the number of required proprioceptive measurements. Project page: https://brittonjordan.github.io/probe_mde/
26.6ROMar 24
PinPoint: Monocular Needle Pose Estimation for Robotic Suturing via Stein Variational Newton and Geometric ResidualsJesse F. d'Almeida, Tanner Watts, Susheela Sharma Stern et al.
Reliable estimation of surgical needle 3D position and orientation is essential for autonomous robotic suturing, yet existing methods operate almost exclusively under stereoscopic vision. In monocular endoscopic settings, common in transendoscopic and intraluminal procedures, depth ambiguity and rotational symmetry render needle pose estimation inherently ill-posed, producing a multimodal distribution over feasible configurations, rather than a single, well-grounded estimate. We present PinPoint, a probabilistic variational inference framework that treats this ambiguity directly, maintaining a distribution of pose hypotheses rather than suppressing it. PinPoint combines monocular image observations with robot-grasp constraints through analytical geometric likelihoods with closed-form Jacobians. This framework enables efficient Gauss-Newton preconditioning in a Stein Variational Newton inference, where second-order particle transport deterministically moves particles toward high-probability regions while kernel-based repulsion preserves diversity in the multimodal structure. On real needle-tracking sequences, PinPoint reduces mean translational error by 80% (down to 1.00 mm) and rotational error by 78% (down to 13.80°) relative to a particle-filter baseline, with substantially better-calibrated uncertainty. On induced-rotation sequences, where monocular ambiguity is most severe, PinPoint maintains a bimodal posterior 84% of the time, almost three times the rate of the particle filter baseline, correctly preserving the alternative hypothesis rather than committing prematurely to one mode. Suturing experiments in ex vivo tissue demonstrate stable tracking through intermittent occlusion, with average errors during occlusion of 1.34 mm in translation and 19.18° in rotation, even when the needle is fully embedded.
CVMar 20, 2025
From Monocular Vision to Autonomous Action: Guiding Tumor Resection via 3D ReconstructionAyberk Acar, Mariana Smith, Lidia Al-Zogbi et al.
Surgical automation requires precise guidance and understanding of the scene. Current methods in the literature rely on bulky depth cameras to create maps of the anatomy, however this does not translate well to space-limited clinical applications. Monocular cameras are small and allow minimally invasive surgeries in tight spaces but additional processing is required to generate 3D scene understanding. We propose a 3D mapping pipeline that uses only RGB images to create segmented point clouds of the target anatomy. To ensure the most precise reconstruction, we compare different structure from motion algorithms' performance on mapping the central airway obstructions, and test the pipeline on a downstream task of tumor resection. In several metrics, including post-procedure tissue model evaluation, our pipeline performs comparably to RGB-D cameras and, in some cases, even surpasses their performance. These promising results demonstrate that automation guidance can be achieved in minimally invasive procedures with monocular cameras. This study is a step toward the complete autonomy of surgical robots.
ROSep 16, 2025
Semantic 3D Reconstructions with SLAM for Central Airway ObstructionAyberk Acar, Fangjie Li, Hao Li et al.
Central airway obstruction (CAO) is a life-threatening condition with increasing incidence, caused by tumors in and outside of the airway. Traditional treatment methods such as bronchoscopy and electrocautery can be used to remove the tumor completely; however, these methods carry a high risk of complications. Recent advances allow robotic interventions with lesser risk. The combination of robot interventions with scene understanding and mapping also opens up the possibilities for automation. We present a novel pipeline that enables real-time, semantically informed 3D reconstructions of the central airway using monocular endoscopic video. Our approach combines DROID-SLAM with a segmentation model trained to identify obstructive tissues. The SLAM module reconstructs the 3D geometry of the airway in real time, while the segmentation masks guide the annotation of obstruction regions within the reconstructed point cloud. To validate our pipeline, we evaluate the reconstruction quality using ex vivo models. Qualitative and quantitative results show high similarity between ground truth CT scans and the 3D reconstructions (0.62 mm Chamfer distance). By integrating segmentation directly into the SLAM workflow, our system produces annotated 3D maps that highlight clinically relevant regions in real time. High-speed capabilities of the pipeline allows quicker reconstructions compared to previous work, reflecting the surgical scene more accurately. To the best of our knowledge, this is the first work to integrate semantic segmentation with real-time monocular SLAM for endoscopic CAO scenarios. Our framework is modular and can generalize to other anatomies or procedures with minimal changes, offering a promising step toward autonomous robotic interventions.