Berkin Bilgic

IV
h-index39
20papers
228citations
Novelty51%
AI Score50

20 Papers

IVAug 9, 2023
Improved Multi-Shot Diffusion-Weighted MRI with Zero-Shot Self-Supervised Learning Reconstruction

Jaejin Cho, Yohan Jun, Xiaoqing Wang et al.

Diffusion MRI is commonly performed using echo-planar imaging (EPI) due to its rapid acquisition time. However, the resolution of diffusion-weighted images is often limited by magnetic field inhomogeneity-related artifacts and blurring induced by T2- and T2*-relaxation effects. To address these limitations, multi-shot EPI (msEPI) combined with parallel imaging techniques is frequently employed. Nevertheless, reconstructing msEPI can be challenging due to phase variation between multiple shots. In this study, we introduce a novel msEPI reconstruction approach called zero-MIRID (zero-shot self-supervised learning of Multi-shot Image Reconstruction for Improved Diffusion MRI). This method jointly reconstructs msEPI data by incorporating deep learning-based image regularization techniques. The network incorporates CNN denoisers in both k- and image-spaces, while leveraging virtual coils to enhance image reconstruction conditioning. By employing a self-supervised learning technique and dividing sampled data into three groups, the proposed approach achieves superior results compared to the state-of-the-art parallel imaging method, as demonstrated in an in-vivo experiment.

10.9IVMar 27
FINDER: Zero-Shot Field-Integrated Network for Distortion-free EPI Reconstruction in Diffusion MRI

Namgyu Han, Seong Dae Yun, Chaeeun Lim et al.

Echo-planar imaging (EPI) remains the cornerstone of diffusion MRI, but it is prone to severe geometric distortions due to its rapid sampling scheme that renders the sequence highly sensitive to $B_{0}$ field inhomogeneities. While deep learning has helped improve MRI reconstruction, integrating robust geometric distortion correction into a self-supervised framework remains an unmet need. To address this, we present FINDER (Field-Integrated Network for Distortion-free EPI Reconstruction), a novel zero-shot, scan-specific framework that reformulates reconstruction as a joint optimization of the underlying image and the $B_{0}$ field map. Specifically, we employ a physics-guided unrolled network that integrates dual-domain denoisers and virtual coil extensions to enforce robust data consistency. This is coupled with an Implicit Neural Representation (INR) conditioned on spatial coordinates and latent image features to model the off-resonance field as a continuous, differentiable function. Employing an alternating minimization strategy, FINDER synergistically updates the reconstruction network and the field map, effectively disentangling susceptibility-induced geometric distortions from anatomical structures. Experimental results demonstrate that FINDER achieves superior geometric fidelity and image quality compared to state-of-the-art baselines, offering a robust solution for high-quality diffusion imaging.

IVDec 16, 2025
Deep learning water-unsuppressed MRSI at ultra-high field for simultaneous quantitative metabolic, susceptibility and myelin water imaging

Paul J. Weiser, Jiye Kim, Jongho Lee et al.

Purpose: Magnetic Resonance Spectroscopic Imaging (MRSI) maps endogenous brain metabolism while suppressing the overwhelming water signal. Water-unsuppressed MRSI (wu-MRSI) allows simultaneous imaging of water and metabolites, but large water sidebands cause challenges for metabolic fitting. We developed an end-to-end deep-learning pipeline to overcome these challenges at ultra-high field. Methods:Fast high-resolution wu-MRSI was acquired at 7T with non-cartesian ECCENTRIC sampling and ultra-short echo time. A water and lipid removal network (WALINET+) was developed to remove lipids, water signal, and sidebands. MRSI reconstruction was performed by DeepER and a physics-informed network for metabolite fitting. Water signal was used for absolute metabolite quantification, quantitative susceptibility mapping (QSM), and myelin water fraction imaging (MWF). Results: WALINET+ provided the lowest NRMSE (< 2%) in simulations and in vivo the smallest bias (< 20%) and limits-of-agreement (+-63%) between wu-MRSI and ws-MRSI scans. Several metabolites such as creatine and glutamate showed higher SNR in wu-MRSI. QSM and MWF obtained from wu-MRSI and GRE showed good agreement with 0 ppm/5.5% bias and +-0.05 ppm/ +- 12.75% limits-of-agreement. Conclusion: High-quality metabolic, QSM, and MWF mapping of the human brain can be obtained simultaneously by ECCENTRIC wu-MRSI at 7T with 2 mm isotropic resolution in 12 min. WALINET+ robustly removes water sidebands while preserving metabolite signal, eliminating the need for water suppression and separate water acquisitions.

IVNov 28, 2023
SubZero: Subspace Zero-Shot MRI Reconstruction

Heng Yu, Yamin Arefeen, Berkin Bilgic

Recently introduced zero-shot self-supervised learning (ZS-SSL) has shown potential in accelerated MRI in a scan-specific scenario, which enabled high-quality reconstructions without access to a large training dataset. ZS-SSL has been further combined with the subspace model to accelerate 2D T2-shuffling acquisitions. In this work, we propose a parallel network framework and introduce an attention mechanism to improve subspace-based zero-shot self-supervised learning and enable higher acceleration factors. We name our method SubZero and demonstrate that it can achieve improved performance compared with current methods in T1 and T2 mapping acquisitions.

IVNov 27, 2025Code
GACELLE: GPU-accelerated tools for model parameter estimation and image reconstruction

Kwok-Shing Chan, Hansol Lee, Yixin Ma et al.

Quantitative MRI (qMRI) offers tissue-specific biomarkers that can be tracked over time or compared across populations; however, its adoption in clinical research is hindered by significant computational demands of parameter estimation. Images acquired at high spatial resolution or requiring fitting multiple parameters often require lengthy processing time, constraining their use in routine pipelines and slowing methodological innovation and clinical translation. We present GACELLE, an open source, GPU-accelerated framework for high-throughput qMRI analysis. GACELLE provides a stochastic gradient descent optimiser and a stochastic sampler in MATLAB, enabling fast parameter mapping, improved estimation robustness via spatial regularisation, and uncertainty quantification. GACELLE prioritises accessibility: users only need to provide a forward signal model, while GACELLE's backend manages computational parallelisation, automatic parameter updates, and memory-batching. The stochastic solver performs fully vectorised Markov chain Monte Carlo with identical likelihood on CPU and GPU, ensuring reproducibility across hardware. Benchmarking demonstrates up to 451-fold acceleration for the stochastic gradient descent solver and 14,380-fold acceleration for stochastic sampling compared to CPU-based estimation, without compromising accuracy. We demonstrated GACELLE's versatility on three representative qMRI models and on an image reconstruction task. Across these applications, GACELLE improves parameter precision, enhances test-retest reproducibility, and reduces noise in quantitative maps. By combining speed, usability and flexibility, GACELLE provides a generalisable optimisation framework for medical image analysis. It lowers the computational barrier for qMRI, paving the way for reproducible biomarker development, large-scale imaging studies, and clinical translation.

MED-PHSep 11, 2025
Explainable AI for Accelerated Microstructure Imaging: A SHAP-Guided Protocol on the Connectome 2.0 scanner

Quentin Uhl, Tommaso Pavan, Julianna Gerold et al.

The diffusion MRI Neurite Exchange Imaging model offers a promising framework for probing gray matter microstructure by estimating parameters such as compartment sizes, diffusivities, and inter-compartmental water exchange time. However, existing protocols require long scan times. This study proposes a reduced acquisition scheme for the Connectome 2.0 scanner that preserves model accuracy while substantially shortening scan duration. We developed a data-driven framework using explainable artificial intelligence with a guided recursive feature elimination strategy to identify an optimal 8-feature subset from a 15-feature protocol. The performance of this optimized protocol was validated in vivo and benchmarked against the full acquisition and alternative reduction strategies. Parameter accuracy, preservation of anatomical contrast, and test-retest reproducibility were assessed. The reduced protocol yielded parameter estimates and cortical maps comparable to the full protocol, with low estimation errors in synthetic data and minimal impact on test-retest variability. Compared to theory-driven and heuristic reduction schemes, the optimized protocol demonstrated superior robustness, reducing the deviation in water exchange time estimates by over two-fold. In conclusion, this hybrid optimization framework enables viable imaging of neurite exchange in 14 minutes without loss of parameter fidelity. This approach supports the broader application of exchange-sensitive diffusion magnetic resonance imaging in neuroscience and clinical research, and offers a generalizable method for designing efficient acquisition protocols in biophysical parameter mapping.

IVFeb 12, 2025
Rapid Whole Brain Motion-robust Mesoscale In-vivo MR Imaging using Multi-scale Implicit Neural Representation

Jun Lyu, Lipeng Ning, William Consagra et al.

High-resolution whole-brain in vivo MR imaging at mesoscale resolutions remains challenging due to long scan durations, motion artifacts, and limited signal-to-noise ratio (SNR). This study proposes Rotating-view super-resolution (ROVER)-MRI, an unsupervised framework based on multi-scale implicit neural representations (INR), enabling efficient recovery of fine anatomical details from multi-view thick-slice acquisitions. ROVER-MRI employs coordinate-based neural networks to implicitly and continuously encode image structures at multiple spatial scales, simultaneously modeling anatomical continuity and correcting inter-view motion through an integrated registration mechanism. Validation on ex-vivo monkey brain data and multiple in-vivo human datasets demonstrates substantially improved reconstruction performance compared to bicubic interpolation and state-of-the-art regularized least-squares super-resolution reconstruction (LS-SRR) with 2-fold reduction in scan time. Notably, ROVER-MRI achieves an unprecedented whole-brain in-vivo T2-weighted imaging at 180 micron isotropic resolution in only 17 minutes of scan time on a 7T scanner with 22.4% lower relative error compared to LS-SRR. We also demonstrate improved SNR using ROVER-MRI compared to a time-matched 3D GRE acquisition. Quantitative results on several datasets demonstrate better sharpness of the reconstructed images with ROVER-MRI for different super-resolution factors (5 to 11). These findings highlight ROVER-MRI's potential as a rapid, accurate, and motion-resilient mesoscale imaging solution, promising substantial advantages for neuroimaging studies.

IVJan 22, 2024
NLCG-Net: A Model-Based Zero-Shot Learning Framework for Undersampled Quantitative MRI Reconstruction

Xinrui Jiang, Yohan Jun, Jaejin Cho et al.

Typical quantitative MRI (qMRI) methods estimate parameter maps after image reconstructing, which is prone to biases and error propagation. We propose a Nonlinear Conjugate Gradient (NLCG) optimizer for model-based T2/T1 estimation, which incorporates U-Net regularization trained in a scan-specific manner. This end-to-end method directly estimates qMRI maps from undersampled k-space data using mono-exponential signal modeling with zero-shot scan-specific neural network regularization to enable high fidelity T1 and T2 mapping. T2 and T1 mapping results demonstrate the ability of the proposed NLCG-Net to improve estimation quality compared to subspace reconstruction at high accelerations.

SPFeb 25, 2022
High-Dimensional Sparse Bayesian Learning without Covariance Matrices

Alexander Lin, Andrew H. Song, Berkin Bilgic et al.

Sparse Bayesian learning (SBL) is a powerful framework for tackling the sparse coding problem. However, the most popular inference algorithms for SBL become too expensive for high-dimensional settings, due to the need to store and compute a large covariance matrix. We introduce a new inference scheme that avoids explicit construction of the covariance matrix by solving multiple linear systems in parallel to obtain the posterior moments for SBL. Our approach couples a little-known diagonal estimation result from numerical linear algebra with the conjugate gradient algorithm. On several simulations, our method scales better than existing approaches in computation time and memory, especially for structured dictionaries capable of fast matrix-vector multiplication.

IVFeb 6, 2022
Wave-Encoded Model-based Deep Learning for Highly Accelerated Imaging with Joint Reconstruction

Jaejin Cho, Borjan Gagoski, Taehyung Kim et al.

Purpose: To propose a wave-encoded model-based deep learning (wave-MoDL) strategy for highly accelerated 3D imaging and joint multi-contrast image reconstruction, and further extend this to enable rapid quantitative imaging using an interleaved look-locker acquisition sequence with T2 preparation pulse (3D-QALAS). Method: Recently introduced MoDL technique successfully incorporates convolutional neural network (CNN)-based regularizers into physics-based parallel imaging reconstruction using a small number of network parameters. Wave-CAIPI is an emerging parallel imaging method that accelerates the imaging speed by employing sinusoidal gradients in the phase- and slice-encoding directions during the readout to take better advantage of 3D coil sensitivity profiles. In wave-MoDL, we propose to combine the wave-encoding strategy with unrolled network constraints to accelerate the acquisition speed while enforcing wave-encoded data consistency. We further extend wave-MoDL to reconstruct multi-contrast data with controlled aliasing in parallel imaging (CAIPI) sampling patterns to leverage similarity between multiple images to improve the reconstruction quality. Result: Wave-MoDL enables a 47-second MPRAGE acquisition at 1 mm resolution at 16-fold acceleration. For quantitative imaging, wave-MoDL permits a 2-minute acquisition for T1, T2, and proton density mapping at 1 mm resolution at 12-fold acceleration, from which contrast weighted images can be synthesized as well. Conclusion: Wave-MoDL allows rapid MR acquisition and high-fidelity image reconstruction and may facilitate clinical and neuroscientific applications by incorporating unrolled neural networks into wave-CAIPI reconstruction.

IVDec 7, 2021
Accurate parameter estimation using scan-specific unsupervised deep learning for relaxometry and MR fingerprinting

Mengze Gao, Huihui Ye, Tae Hyung Kim et al.

We propose an unsupervised convolutional neural network (CNN) for relaxation parameter estimation. This network incorporates signal relaxation and Bloch simulations while taking advantage of residual learning and spatial relations across neighboring voxels. Quantification accuracy and robustness to noise is shown to be significantly improved compared to standard parameter estimation methods in numerical simulations and in vivo data for multi-echo T2 and T2* mapping. The combination of the proposed network with subspace modeling and MR fingerprinting (MRF) from highly undersampled data permits high quality T1 and T2 mapping.

IVDec 2, 2021
Improving accuracy and uncertainty quantification of deep learning based quantitative MRI using Monte Carlo dropout

Mehmet Yigit Avci, Ziyu Li, Qiuyun Fan et al.

Dropout is conventionally used during the training phase as regularization method and for quantifying uncertainty in deep learning. We propose to use dropout during training as well as inference steps, and average multiple predictions to improve the accuracy, while reducing and quantifying the uncertainty. The results are evaluated for fractional anisotropy (FA) and mean diffusivity (MD) maps which are obtained from only 3 direction scans. With our method, accuracy can be improved significantly compared to network outputs without dropout, especially when the training dataset is small. Moreover, confidence maps are generated which may aid in diagnosis of unseen pathology or artifacts.

IVNov 14, 2021
SDnDTI: Self-supervised deep learning-based denoising for diffusion tensor MRI

Qiyuan Tian, Ziyu Li, Qiuyun Fan et al.

The noise in diffusion-weighted images (DWIs) decreases the accuracy and precision of diffusion tensor magnetic resonance imaging (DTI) derived microstructural parameters and leads to prolonged acquisition time for achieving improved signal-to-noise ratio (SNR). Deep learning-based image denoising using convolutional neural networks (CNNs) has superior performance but often requires additional high-SNR data for supervising the training of CNNs, which reduces the practical feasibility. We develop a self-supervised deep learning-based method entitled "SDnDTI" for denoising DTI data, which does not require additional high-SNR data for training. Specifically, SDnDTI divides multi-directional DTI data into many subsets, each consisting of six DWI volumes along optimally chosen diffusion-encoding directions that are robust to noise for the tensor fitting, and then synthesizes DWI volumes along all acquired directions from the diffusion tensors fitted using each subset of the data as the input data of CNNs. On the other hand, SDnDTI synthesizes DWI volumes along acquired diffusion-encoding directions with higher SNR from the diffusion tensors fitted using all acquired data as the training target. SDnDTI removes noise from each subset of synthesized DWI volumes using a deep 3-dimensional CNN to match the quality of the cleaner target DWI volumes and achieves even higher SNR by averaging all subsets of denoised data. The denoising efficacy of SDnDTI is demonstrated on two datasets provided by the Human Connectome Project (HCP) and the Lifespan HCP in Aging. The SDnDTI results preserve image sharpness and textural details and substantially improve upon those from the raw data. The results of SDnDTI are comparable to those from supervised learning-based denoising and outperform those from state-of-the-art conventional denoising algorithms including BM4D, AONLM and MPPCA.

CVJul 7, 2021
eRAKI: Fast Robust Artificial neural networks for K-space Interpolation (RAKI) with Coil Combination and Joint Reconstruction

Heng Yu, Zijing Dong, Yamin Arefeen et al.

RAKI can perform database-free MRI reconstruction by training models using only auto-calibration signal (ACS) from each specific scan. As it trains a separate model for each individual coil, learning and inference with RAKI can be computationally prohibitive, particularly for large 3D datasets. In this abstract, we accelerate RAKI more than 200 times by directly learning a coil-combined target and further improve the reconstruction performance using joint reconstruction across multiple echoes together with an elliptical-CAIPI sampling approach. We further deploy these improvements in quantitative imaging and rapidly obtain T2 and T2* parameter maps from a fast EPTI scan.

SPMay 21, 2021
Covariance-Free Sparse Bayesian Learning

Alexander Lin, Andrew H. Song, Berkin Bilgic et al.

Sparse Bayesian learning (SBL) is a powerful framework for tackling the sparse coding problem while also providing uncertainty quantification. The most popular inference algorithms for SBL exhibit prohibitively large computational costs for high-dimensional problems due to the need to maintain a large covariance matrix. To resolve this issue, we introduce a new method for accelerating SBL inference -- named covariance-free expectation maximization (CoFEM) -- that avoids explicit computation of the covariance matrix. CoFEM solves multiple linear systems to obtain unbiased estimates of the posterior statistics needed by SBL. This is accomplished by exploiting innovations from numerical linear algebra such as preconditioned conjugate gradient and a little-known diagonal estimation rule. For a large class of compressed sensing matrices, we provide theoretical justifications for why our method scales well in high-dimensional settings. Through simulations, we show that CoFEM can be up to thousands of times faster than existing baselines without sacrificing coding accuracy. Through applications to calcium imaging deconvolution and multi-contrast MRI reconstruction, we show that CoFEM enables SBL to tractably tackle high-dimensional sparse coding problems of practical interest.

SPApr 2, 2021
Scan Specific Artifact Reduction in K-space (SPARK) Neural Networks Synergize with Physics-based Reconstruction to Accelerate MRI

Yamin Arefeen, Onur Beker, Jaejin Cho et al.

Purpose: To develop a scan-specific model that estimates and corrects k-space errors made when reconstructing accelerated Magnetic Resonance Imaging (MRI) data. Methods: Scan-Specific Artifact Reduction in k-space (SPARK) trains a convolutional-neural-network to estimate and correct k-space errors made by an input reconstruction technique by back-propagating from the mean-squared-error loss between an auto-calibration signal (ACS) and the input technique's reconstructed ACS. First, SPARK is applied to GRAPPA and demonstrates improved robustness over other scan-specific models, such as RAKI and residual-RAKI. Subsequent experiments demonstrate that SPARK synergizes with residual-RAKI to improve reconstruction performance. SPARK also improves reconstruction quality when applied to advanced acquisition and reconstruction techniques like 2D virtual coil (VC-) GRAPPA, 2D LORAKS, 3D GRAPPA without an integrated ACS region, and 2D/3D wave-encoded images. Results: SPARK yields 1.5x - 2x RMSE reduction when applied to GRAPPA and improves robustness to ACS size for various acceleration rates in comparison to other scan-specific techniques. When applied to advanced reconstruction techniques such as residual-RAKI, 2D VC-GRAPPA and LORAKS, SPARK achieves up to 20% RMSE improvement. SPARK with 3D GRAPPA also improves performance by ~2x and perceived image quality without a fully sampled ACS region. Finally, SPARK synergizes with non-cartesian 2D and 3D wave-encoding imaging by reducing RMSE between 20-25% and providing qualitative improvements. Conclusion: SPARK synergizes with physics-based acquisition and reconstruction techniques to improve accelerated MRI by training scan-specific models to estimate and correct reconstruction errors in k-space.

IVFeb 17, 2021
SRDTI: Deep learning-based super-resolution for diffusion tensor MRI

Qiyuan Tian, Ziyu Li, Qiuyun Fan et al.

High-resolution diffusion tensor imaging (DTI) is beneficial for probing tissue microstructure in fine neuroanatomical structures, but long scan times and limited signal-to-noise ratio pose significant barriers to acquiring DTI at sub-millimeter resolution. To address this challenge, we propose a deep learning-based super-resolution method entitled "SRDTI" to synthesize high-resolution diffusion-weighted images (DWIs) from low-resolution DWIs. SRDTI employs a deep convolutional neural network (CNN), residual learning and multi-contrast imaging, and generates high-quality results with rich textural details and microstructural information, which are more similar to high-resolution ground truth than those from trilinear and cubic spline interpolation.

IVSep 30, 2019
Nonlinear Dipole Inversion (NDI) enables Quantitative Susceptibility Mapping (QSM) without parameter tuning

Daniel Polak, Itthi Chatnuntawech, Jaeyeon Yoon et al.

We propose Nonlinear Dipole Inversion (NDI) for high-quality Quantitative Susceptibility Mapping (QSM) without regularization tuning, while matching the image quality of state-of-the-art reconstruction techniques. In addition to avoiding over-smoothing that these techniques often suffer from, we also obviate the need for parameter selection. NDI is flexible enough to allow for reconstruction from an arbitrary number of head orientations, and outperforms COSMOS even when using as few as 1-direction data. This is made possible by a nonlinear forward-model that uses the magnitude as an effective prior, for which we derived a simple gradient descent update rule. We synergistically combine this physics-model with a Variational Network (VN) to leverage the power of deep learning in the VaNDI algorithm. This technique adopts the simple gradient descent rule from NDI and learns the network parameters during training, hence requires no additional parameter tuning. Further, we evaluate NDI at 7T using highly accelerated Wave-CAIPI acquisitions at 0.5 mm isotropic resolution and demonstrate high-quality QSM from as few as 2-direction data.

IVAug 8, 2018
Highly Accelerated Multishot EPI through Synergistic Machine Learning and Joint Reconstruction

Berkin Bilgic, Itthi Chatnuntawech, Mary Kate Manhard et al.

Purpose: To introduce a combined machine learning (ML) and physics-based image reconstruction framework that enables navigator-free, highly accelerated multishot echo planar imaging (msEPI), and demonstrate its application in high-resolution structural and diffusion imaging. Methods: Singleshot EPI is an efficient encoding technique, but does not lend itself well to high-resolution imaging due to severe distortion artifacts and blurring. While msEPI can mitigate these artifacts, high-quality msEPI has been elusive because of phase mismatch arising from shot-to-shot variations which preclude the combination of the multiple-shot data into a single image. We employ deep learning to obtain an interim image with minimal artifacts, which permits estimation of image phase variations due to shot-to-shot changes. These variations are then included in a Joint Virtual Coil Sensitivity Encoding (JVC-SENSE) reconstruction to utilize data from all shots and improve upon the ML solution. Results: Our combined ML + physics approach enabled Rinplane x MultiBand (MB) = 8x2-fold acceleration using 2 EPI-shots for multi-echo imaging, so that whole-brain T2 and T2* parameter maps could be derived from an 8.3 sec acquisition at 1x1x3mm3 resolution. This has also allowed high-resolution diffusion imaging with high geometric fidelity using 5-shots at Rinplane x MB = 9x2-fold acceleration. To make these possible, we extended the state-of-the-art MUSSELS reconstruction technique to Simultaneous MultiSlice (SMS) encoding and used it as an input to our ML network. Conclusion: Combination of ML and JVC-SENSE enabled navigator-free msEPI at higher accelerations than previously possible while using fewer shots, with reduced vulnerability to poor generalizability and poor acceptance of end-to-end ML approaches.

CVMay 29, 2018
Rice Classification Using Spatio-Spectral Deep Convolutional Neural Network

Itthi Chatnuntawech, Kittipong Tantisantisom, Paisan Khanchaitit et al.

Rice has been one of the staple foods that contribute significantly to human food supplies. Numerous rice varieties have been cultivated, imported, and exported worldwide. Different rice varieties could be mixed during rice production and trading. Rice impurities could damage the trust between rice importers and exporters, calling for the need to develop a rice variety inspection system. In this work, we develop a non-destructive rice variety classification system that benefits from the synergy between hyperspectral imaging and deep convolutional neural network (CNN). The proposed method uses a hyperspectral imaging system to simultaneously acquire complementary spatial and spectral information of rice seeds. The rice varieties are then determined from the acquired spatio-spectral data using a deep CNN. As opposed to several existing rice variety classification methods that require hand-engineered features, the proposed method automatically extracts spatio-spectral features from the raw sensor data. As demonstrated using two types of rice datasets, the proposed method achieved up to 11.9% absolute improvement in the mean classification accuracy, compared to the commonly used classification methods based on support vector machines.