36.8CVMay 28
DefSynUS: Real-time Patient-specific Intrahepatic Vessel Identification via Deformation-Aware CT-US Domain Adaptation

Karl-Philippe Beaudet, Yordanka Velikova, Sidaty El Hadramy et al.

Purpose: Laparoscopic ultrasound (LUS) enhances the safety of liver surgery by visualizing intrahepatic vessels in real-time. Still, vessel identification remains difficult due to probe constraints, complex vascular structure, and tissue deformation. This work aims to enable real-time, patient-specific vessel identification that remains robust under deformation through deformable ultrasound augmentation. Methods: Preoperative CT vessel annotations are used to generate synthetic ultrasound data via optimized physics-based rendering, coupled with domain adaptation to intraoperative ultrasound. The rendering is trained end-to-end for vessel identification and patient-specificity, eliminating the need for preoperative ultrasound. A deformation-aware augmentation simulates realistic intraoperative motion and tissue deformation within the rendering pipeline. Results: In abdominal phantom and limited clinical feasibility experiments (single-case clinical evaluation), the framework achieved real-time intrahepatic vessel-branch identification, maintaining performance under new patient poses. Conclusion: The framework enables real-time vessel identification without preoperative ultrasound and supports technical feasibility, but multi-patient validation is still needed for generalizability and clinical feasibility.

CVAug 28, 2025
Optimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction

Karl-Philippe Beaudet, Sidaty El Hadramy, Philippe C Cattin et al.

Intraoperative ultrasound images are inherently challenging to interpret in liver surgery due to the limited field of view and complex anatomical structures. Bridging the gap between preoperative and intraoperative data is crucial for effective surgical guidance. 3D IntraVascular UltraSound (IVUS) offers a potential solution by enabling the reconstruction of the entire organ, which facilitates registration between preoperative computed tomography (CT) scans and intraoperative IVUS images. In this work, we propose an optimization-based calibration method using a 3D-printed phantom for accurate 3D Intravascular Ultrasound volume reconstruction. Our approach ensures precise alignment of tracked IVUS data with preoperative CT images, improving intraoperative navigation. We validated our method using in vivo swine liver images, achieving a calibration error from 0.88 to 1.80 mm and a registration error from 3.40 to 5.71 mm between the 3D IVUS data and the corresponding CT scan. Our method provides a reliable and accurate means of calibration and volume reconstruction. It can be used to register intraoperative ultrasound images with preoperative CT images in the context of liver surgery, and enhance intraoperative guidance.