LGJan 23
PUNCH: Physics-informed Uncertainty-aware Network for Coronary HemodynamicsSukirt Thakur, Marcus Roper, Yang Zhou et al.
More than 10 million coronary angiograms are performed globally each year, providing a gold standard for detecting obstructive coronary artery disease. Yet, no obstructive lesions are identified in 70% of patients evaluated for ischemic heart disease. Up to half of these patients have undiagnosed, life-limiting coronary microvascular dysfunction (CMD), which remains under-detected due to the limited availability of invasive tools required to measure coronary flow reserve (CFR). Here, we introduce PUNCH, a non-invasive, uncertainty-aware framework for estimating CFR directly from standard coronary angiography. PUNCH integrates physics-informed neural networks with variational inference to infer coronary blood flow from first-principles models of contrast transport, without requiring ground-truth flow measurements or population-level training. The pipeline runs in approximately three minutes per patient on a single GPU. Validated on synthetic angiograms with controlled noise and imaging artifacts, as well as on clinical bolus thermodilution data from 20 patients, PUNCH demonstrates accurate and uncertainty-calibrated CFR estimation. This approach establishes a new paradigm for CMD diagnosis and illustrates how physics-informed inference can substantially expand the diagnostic utility of available clinical imaging.
IVNov 20, 2023
Generalized super-resolution 4D Flow MRI $\unicode{x2013}$ using ensemble learning to extend across the cardiovascular systemLeon Ericsson, Adam Hjalmarsson, Muhammad Usman Akbar et al.
4D Flow Magnetic Resonance Imaging (4D Flow MRI) is a non-invasive measurement technique capable of quantifying blood flow across the cardiovascular system. While practical use is limited by spatial resolution and image noise, incorporation of trained super-resolution (SR) networks has potential to enhance image quality post-scan. However, these efforts have predominantly been restricted to narrowly defined cardiovascular domains, with limited exploration of how SR performance extends across the cardiovascular system; a task aggravated by contrasting hemodynamic conditions apparent across the cardiovasculature. The aim of our study was to explore the generalizability of SR 4D Flow MRI using a combination of heterogeneous training sets and dedicated ensemble learning. With synthetic training data generated across three disparate domains (cardiac, aortic, cerebrovascular), varying convolutional base and ensemble learners were evaluated as a function of domain and architecture, quantifying performance on both in-silico and acquired in-vivo data from the same three domains. Results show that both bagging and stacking ensembling enhance SR performance across domains, accurately predicting high-resolution velocities from low-resolution input data in-silico. Likewise, optimized networks successfully recover native resolution velocities from downsampled in-vivo data, as well as show qualitative potential in generating denoised SR-images from clinical level input data. In conclusion, our work presents a viable approach for generalized SR 4D Flow MRI, with ensemble learning extending utility across various clinical areas of interest.
IVAug 20, 2025
Potential and challenges of generative adversarial networks for super-resolution in 4D Flow MRIOliver Welin Odeback, Arivazhagan Geetha Balasubramanian, Jonas Schollenberger et al.
4D Flow Magnetic Resonance Imaging (4D Flow MRI) enables non-invasive quantification of blood flow and hemodynamic parameters. However, its clinical application is limited by low spatial resolution and noise, particularly affecting near-wall velocity measurements. Machine learning-based super-resolution has shown promise in addressing these limitations, but challenges remain, not least in recovering near-wall velocities. Generative adversarial networks (GANs) offer a compelling solution, having demonstrated strong capabilities in restoring sharp boundaries in non-medical super-resolution tasks. Yet, their application in 4D Flow MRI remains unexplored, with implementation challenged by known issues such as training instability and non-convergence. In this study, we investigate GAN-based super-resolution in 4D Flow MRI. Training and validation were conducted using patient-specific cerebrovascular in-silico models, converted into synthetic images via an MR-true reconstruction pipeline. A dedicated GAN architecture was implemented and evaluated across three adversarial loss functions: Vanilla, Relativistic, and Wasserstein. Our results demonstrate that the proposed GAN improved near-wall velocity recovery compared to a non-adversarial reference (vNRMSE: 6.9% vs. 9.6%); however, that implementation specifics are critical for stable network training. While Vanilla and Relativistic GANs proved unstable compared to generator-only training (vNRMSE: 8.1% and 7.8% vs. 7.2%), a Wasserstein GAN demonstrated optimal stability and incremental improvement (vNRMSE: 6.9% vs. 7.2%). The Wasserstein GAN further outperformed the generator-only baseline at low SNR (vNRMSE: 8.7% vs. 10.7%). These findings highlight the potential of GAN-based super-resolution in enhancing 4D Flow MRI, particularly in challenging cerebrovascular regions, while emphasizing the need for careful selection of adversarial strategies.