Adam M. Saunders

CV
h-index51
9papers
13citations
Novelty40%
AI Score40

9 Papers

CVSep 6, 2024
Influence of Early through Late Fusion on Pancreas Segmentation from Imperfectly Registered Multimodal MRI

Lucas W. Remedios, Han Liu, Samuel W. Remedios et al.

Multimodal fusion promises better pancreas segmentation. However, where to perform fusion in models is still an open question. It is unclear if there is a best location to fuse information when analyzing pairs of imperfectly aligned images. Two main alignment challenges in this pancreas segmentation study are 1) the pancreas is deformable and 2) breathing deforms the abdomen. Even after image registration, relevant deformations are often not corrected. We examine how early through late fusion impacts pancreas segmentation. We used 353 pairs of T2-weighted (T2w) and T1-weighted (T1w) abdominal MR images from 163 subjects with accompanying pancreas labels. We used image registration (deeds) to align the image pairs. We trained a collection of basic UNets with different fusion points, spanning from early to late, to assess how early through late fusion influenced segmentation performance on imperfectly aligned images. We assessed generalization of fusion points on nnUNet. The single-modality T2w baseline using a basic UNet model had a Dice score of 0.73, while the same baseline on the nnUNet model achieved 0.80. For the basic UNet, the best fusion approach occurred in the middle of the encoder (early/mid fusion), which led to a statistically significant improvement of 0.0125 on Dice score compared to the baseline. For the nnUNet, the best fusion approach was naïve image concatenation before the model (early fusion), which resulted in a statistically significant Dice score increase of 0.0021 compared to baseline. Fusion in specific blocks can improve performance, but the best blocks for fusion are model specific, and the gains are small. In imperfectly registered datasets, fusion is a nuanced problem, with the art of design remaining vital for uncovering potential insights. Future innovation is needed to better address fusion in cases of imperfect alignment of abdominal image pairs.

22.4LGMay 13
Unsupervised learning of acquisition variability in structural connectomes via hybrid latent space modeling

Gaurav Rudravaram, Lianrui Zuo, Karthik Ramadass et al.

Acquisition differences across sites, scanners, and protocols in dMRI introduce variability that complicates structural connectome analysis. This motivates deep learning models that can represent high-dimensional connectomes in a low-dimensional space while explicitly separating acquisition-related effects from biological variation. Conventional dimensionality reduction methods model all variance as continuous, so acquisition effects often get absorbed into a continuous latent space. Recent hybrid latent-space models combine discrete and continuous components to address this, but typically require manual capacity tuning to ensure the discrete component captures the intended variability. We introduce an unsupervised framework that removes this manual tuning by architecturally annealing encoder outputs before decoding, allowing the model to adaptively balance discrete and continuous latent variables during training. To evaluate it, we curated a dataset of N=7,416 structural connectomes derived from dMRI, spanning ages 2 to 102 and 13 studies with 25 unique acquisition-parameter combinations. Of these, 5,900 are cognitively unimpaired, 877 have mild cognitive impairment (MCI), and 639 have Alzheimer's disease (AD). We compare against a standard VAE, PCA with k-means clustering, and hybrid models that anneal only through the loss function. Our architectural annealing produces stronger site learning (ARI=0.53, p<0.05) than these baselines. Results show that a hybrid continuous-discrete latent space, with architectural rather than loss-based annealing, provides a useful unsupervised mechanism for capturing acquisition variability in dMRI: by jointly modeling smooth and categorical structure, the Joint-VAE recovers clusters aligned with scanner and protocol differences.

CVOct 29, 2024
Brain age identification from diffusion MRI synergistically predicts neurodegenerative disease

Chenyu Gao, Michael E. Kim, Karthik Ramadass et al.

Estimated brain age from magnetic resonance image (MRI) and its deviation from chronological age can provide early insights into potential neurodegenerative diseases, supporting early detection and implementation of prevention strategies. Diffusion MRI (dMRI) presents an opportunity to build an earlier biomarker for neurodegenerative disease prediction because it captures subtle microstructural changes that precede more perceptible macrostructural changes. However, the coexistence of macro- and micro-structural information in dMRI raises the question of whether current dMRI-based brain age estimation models are leveraging the intended microstructural information or if they inadvertently rely on the macrostructural information. To develop a microstructure-specific brain age, we propose a method for brain age identification from dMRI that mitigates the model's use of macrostructural information by non-rigidly registering all images to a standard template. Imaging data from 13,398 participants across 12 datasets were used for the training and evaluation. We compare our brain age models, trained with and without macrostructural information mitigated, with an architecturally similar T1-weighted (T1w) MRI-based brain age model and two recent, popular, openly available T1w MRI-based brain age models that primarily use macrostructural information. We observe difference between our dMRI-based brain age and T1w MRI-based brain age across stages of neurodegeneration, with dMRI-based brain age being older than T1w MRI-based brain age in participants transitioning from cognitively normal (CN) to mild cognitive impairment (MCI), but younger in participants already diagnosed with Alzheimer's disease (AD). Furthermore, dMRI-based brain age may offer advantages over T1w MRI-based brain age in predicting the transition from CN to MCI up to five years before diagnosis.

IVMay 15, 2024
Data-driven Nucleus Subclassification on Colon H&E using Style-transferred Digital Pathology

Lucas W. Remedios, Shunxing Bao, Samuel W. Remedios et al.

Understanding the way cells communicate, co-locate, and interrelate is essential to furthering our understanding of how the body functions. H&E is widely available, however, cell subtyping often requires expert knowledge and the use of specialized stains. To reduce the annotation burden, AI has been proposed for the classification of cells on H&E. For example, the recent Colon Nucleus Identification and Classification (CoNIC) Challenge focused on labeling 6 cell types on H&E of the colon. However, the CoNIC Challenge was unable to classify epithelial subtypes (progenitor, enteroendocrine, goblet), lymphocyte subtypes (B, helper T, cytotoxic T), and connective subtypes (fibroblasts). We use inter-modality learning to label previously un-labelable cell types on H&E. We take advantage of multiplexed immunofluorescence (MxIF) histology to label 14 cell subclasses. We performed style transfer on the same MxIF tissues to synthesize realistic virtual H&E which we paired with the MxIF-derived cell subclassification labels. We evaluated the efficacy of using a supervised learning scheme where the input was realistic-quality virtual H&E and the labels were MxIF-derived cell subclasses. We assessed our model on private virtual H&E and public real H&E. On virtual H&E, we were able to classify helper T cells and epithelial progenitors with positive predictive values of $0.34 \pm 0.15$ (prevalence $0.03 \pm 0.01$) and $0.47 \pm 0.1$ (prevalence $0.07 \pm 0.02$) respectively, when using ground truth centroid information. On real H&E we could classify helper T cells and epithelial progenitors with upper bound positive predictive values of $0.43 \pm 0.03$ (parent class prevalence 0.21) and $0.94 \pm 0.02$ (parent class prevalence 0.49) when using ground truth centroid information. This is the first work to provide cell type classification for helper T and epithelial progenitor nuclei on H&E.

IVJan 5, 2024
Super-resolution multi-contrast unbiased eye atlases with deep probabilistic refinement

Ho Hin Lee, Adam M. Saunders, Michael E. Kim et al.

Purpose: Eye morphology varies significantly across the population, especially for the orbit and optic nerve. These variations limit the feasibility and robustness of generalizing population-wise features of eye organs to an unbiased spatial reference. Approach: To tackle these limitations, we propose a process for creating high-resolution unbiased eye atlases. First, to restore spatial details from scans with a low through-plane resolution compared to a high in-plane resolution, we apply a deep learning-based super-resolution algorithm. Then, we generate an initial unbiased reference with an iterative metric-based registration using a small portion of subject scans. We register the remaining scans to this template and refine the template using an unsupervised deep probabilistic approach that generates a more expansive deformation field to enhance the organ boundary alignment. We demonstrate this framework using magnetic resonance images across four different tissue contrasts, generating four atlases in separate spatial alignments. Results: For each tissue contrast, we find a significant improvement using the Wilcoxon signed-rank test in the average Dice score across four labeled regions compared to a standard registration framework consisting of rigid, affine, and deformable transformations. These results highlight the effective alignment of eye organs and boundaries using our proposed process. Conclusions: By combining super-resolution preprocessing and deep probabilistic models, we address the challenge of generating an eye atlas to serve as a standardized reference across a largely variable population.

CVAug 20, 2025
Lifespan Pancreas Morphology for Control vs Type 2 Diabetes using AI on Largescale Clinical Imaging

Lucas W. Remedios, Chloe Cho, Trent M. Schwartz et al.

Purpose: Understanding how the pancreas changes is critical for detecting deviations in type 2 diabetes and other pancreatic disease. We measure pancreas size and shape using morphological measurements from ages 0 to 90. Our goals are to 1) identify reliable clinical imaging modalities for AI-based pancreas measurement, 2) establish normative morphological aging trends, and 3) detect potential deviations in type 2 diabetes. Approach: We analyzed a clinically acquired dataset of 2533 patients imaged with abdominal CT or MRI. We resampled the scans to 3mm isotropic resolution, segmented the pancreas using automated methods, and extracted 13 morphological pancreas features across the lifespan. First, we assessed CT and MRI measurements to determine which modalities provide consistent lifespan trends. Second, we characterized distributions of normative morphological patterns stratified by age group and sex. Third, we used GAMLSS regression to model pancreas morphology trends in 1350 patients matched for age, sex, and type 2 diabetes status to identify any deviations from normative aging associated with type 2 diabetes. Results: When adjusting for confounders, the aging trends for 10 of 13 morphological features were significantly different between patients with type 2 diabetes and non-diabetic controls (p < 0.05 after multiple comparisons corrections). Additionally, MRI appeared to yield different pancreas measurements than CT using our AI-based method. Conclusions: We provide lifespan trends demonstrating that the size and shape of the pancreas is altered in type 2 diabetes using 675 control patients and 675 diabetes patients. Moreover, our findings reinforce that the pancreas is smaller in type 2 diabetes. Additionally, we contribute a reference of lifespan pancreas morphology from a large cohort of non-diabetic control patients in a clinical setting.

CVAug 14, 2025
Data-Driven Abdominal Phenotypes of Type 2 Diabetes in Lean, Overweight, and Obese Cohorts

Lucas W. Remedios, Chloe Cho, Trent M. Schwartz et al.

Purpose: Although elevated BMI is a well-known risk factor for type 2 diabetes, the disease's presence in some lean adults and absence in others with obesity suggests that detailed body composition may uncover abdominal phenotypes of type 2 diabetes. With AI, we can now extract detailed measurements of size, shape, and fat content from abdominal structures in 3D clinical imaging at scale. This creates an opportunity to empirically define body composition signatures linked to type 2 diabetes risk and protection using large-scale clinical data. Approach: To uncover BMI-specific diabetic abdominal patterns from clinical CT, we applied our design four times: once on the full cohort (n = 1,728) and once on lean (n = 497), overweight (n = 611), and obese (n = 620) subgroups separately. Briefly, our experimental design transforms abdominal scans into collections of explainable measurements through segmentation, classifies type 2 diabetes through a cross-validated random forest, measures how features contribute to model-estimated risk or protection through SHAP analysis, groups scans by shared model decision patterns (clustering from SHAP) and links back to anatomical differences (classification). Results: The random-forests achieved mean AUCs of 0.72-0.74. There were shared type 2 diabetes signatures in each group; fatty skeletal muscle, older age, greater visceral and subcutaneous fat, and a smaller or fat-laden pancreas. Univariate logistic regression confirmed the direction of 14-18 of the top 20 predictors within each subgroup (p < 0.05). Conclusions: Our findings suggest that abdominal drivers of type 2 diabetes may be consistent across weight classes.

IVMay 28, 2025
Multipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernels

Aravind R. Krishnan, Thomas Z. Li, Lucas W. Remedios et al.

Reconstruction kernels in computed tomography (CT) affect spatial resolution and noise characteristics, introducing systematic variability in quantitative imaging measurements such as emphysema quantification. Choosing an appropriate kernel is therefore essential for consistent quantitative analysis. We propose a multipath cycleGAN model for CT kernel harmonization, trained on a mixture of paired and unpaired data from a low-dose lung cancer screening cohort. The model features domain-specific encoders and decoders with a shared latent space and uses discriminators tailored for each domain.We train the model on 42 kernel combinations using 100 scans each from seven representative kernels in the National Lung Screening Trial (NLST) dataset. To evaluate performance, 240 scans from each kernel are harmonized to a reference soft kernel, and emphysema is quantified before and after harmonization. A general linear model assesses the impact of age, sex, smoking status, and kernel on emphysema. We also evaluate harmonization from soft kernels to a reference hard kernel. To assess anatomical consistency, we compare segmentations of lung vessels, muscle, and subcutaneous adipose tissue generated by TotalSegmentator between harmonized and original images. Our model is benchmarked against traditional and switchable cycleGANs. For paired kernels, our approach reduces bias in emphysema scores, as seen in Bland-Altman plots (p<0.05). For unpaired kernels, harmonization eliminates confounding differences in emphysema (p>0.05). High Dice scores confirm preservation of muscle and fat anatomy, while lung vessel overlap remains reasonable. Overall, our shared latent space multipath cycleGAN enables robust harmonization across paired and unpaired CT kernels, improving emphysema quantification and preserving anatomical fidelity.

IVFeb 7, 2025
Investigating the impact of kernel harmonization and deformable registration on inspiratory and expiratory chest CT images for people with COPD

Aravind R. Krishnan, Yihao Liu, Kaiwen Xu et al.

Paired inspiratory-expiratory CT scans enable the quantification of gas trapping due to small airway disease and emphysema by analyzing lung tissue motion in COPD patients. Deformable image registration of these scans assesses regional lung volumetric changes. However, variations in reconstruction kernels between paired scans introduce errors in quantitative analysis. This work proposes a two-stage pipeline to harmonize reconstruction kernels and perform deformable image registration using data acquired from the COPDGene study. We use a cycle generative adversarial network (GAN) to harmonize inspiratory scans reconstructed with a hard kernel (BONE) to match expiratory scans reconstructed with a soft kernel (STANDARD). We then deformably register the expiratory scans to inspiratory scans. We validate harmonization by measuring emphysema using a publicly available segmentation algorithm before and after harmonization. Results show harmonization significantly reduces emphysema measurement inconsistencies, decreasing median emphysema scores from 10.479% to 3.039%, with a reference median score of 1.305% from the STANDARD kernel as the target. Registration accuracy is evaluated via Dice overlap between emphysema regions on inspiratory, expiratory, and deformed images. The Dice coefficient between inspiratory emphysema masks and deformably registered emphysema masks increases significantly across registration stages (p<0.001). Additionally, we demonstrate that deformable registration is robust to kernel variations.