Medical Diffusion: Denoising Diffusion Probabilistic Models for 3D Medical Image GenerationFiras Khader, Gustav Mueller-Franzes, Soroosh Tayebi Arasteh et al.
Recent advances in computer vision have shown promising results in image generation. Diffusion probabilistic models in particular have generated realistic images from textual input, as demonstrated by DALL-E 2, Imagen and Stable Diffusion. However, their use in medicine, where image data typically comprises three-dimensional volumes, has not been systematically evaluated. Synthetic images may play a crucial role in privacy preserving artificial intelligence and can also be used to augment small datasets. Here we show that diffusion probabilistic models can synthesize high quality medical imaging data, which we show for Magnetic Resonance Images (MRI) and Computed Tomography (CT) images. We provide quantitative measurements of their performance through a reader study with two medical experts who rated the quality of the synthesized images in three categories: Realistic image appearance, anatomical correctness and consistency between slices. Furthermore, we demonstrate that synthetic images can be used in a self-supervised pre-training and improve the performance of breast segmentation models when data is scarce (dice score 0.91 vs. 0.95 without vs. with synthetic data). The code is publicly available on GitHub: https://github.com/FirasGit/medicaldiffusion.
3.6IVSep 13, 2024
Joint image reconstruction and segmentation of real-time cardiac MRI in free-breathing using a model based on disentangled representation learningTobias Wech, Oliver Schad, Simon Sauer et al.
A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed method in undersampled real-time acquisitions based on an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation. Images and predicted LV segmentations were compared to the reference standard of ECG-gated segmented Cartesian cine in repeated breath-holds and corresponding manual segmentation. On a 5-point Likert scale, image quality of the real-time breath-hold approach and Cartesian cine was comparable in healthy participants (RT-BH: 1.99 $\pm$ .98, Cartesian: 1.94 $\pm$ .86, p=.052), but slightly inferior in free-breathing (RT-FB: 2.40 $\pm$ .98, p<.001). In patients with arrhythmia, image quality from both real-time approaches was favourable (RT-BH: 2.10 $\pm$ 1.28, p<.001, RT-FB: 2.40 $\pm$ 1.13, p<.001, Cartesian: 2.68 $\pm$ 1.13). Intra-observer reliability was good (ICC=.77, 95%-confidence interval [.75, .79], p<.001). In functional analysis, a positive bias was observed for ejection fractions derived from the proposed model compared to the clinical reference standard (RT-BH mean EF: 58.5 $\pm$ 5.6%, bias: +3.47%, 95%-confidence interval [-.86, 7.79%], RT-FB mean: 57.9 $\pm$ 10.6%, bias: +1.45%, [-3.02, 5.91%], Cartesian mean: 54.9 $\pm$ 6.7%). The introduced real-time MR imaging technique is capable of acquiring high-quality cardiac cine data in 1-2 minutes without the need for ECG gating and breath-holds. It thus offers a promising alternative to the current clinical practice of segmented acquisition, with shorter scan times, higher patient comfort and increased robustness to arrhythmia and patient incompliance.