IVSep 26, 2022Code
USE-Evaluator: Performance Metrics for Medical Image Segmentation Models with Uncertain, Small or Empty Reference AnnotationsSophie Ostmeier, Brian Axelrod, Jeroen Bertels et al.
Performance metrics for medical image segmentation models are used to measure the agreement between the reference annotation and the predicted segmentation. Usually, overlap metrics, such as the Dice, are used as a metric to evaluate the performance of these models in order for results to be comparable. However, there is a mismatch between the distributions of cases and difficulty level of segmentation tasks in public data sets compared to clinical practice. Common metrics fail to measure the impact of this mismatch, especially for clinical data sets that include low signal pathologies, a difficult segmentation task, and uncertain, small, or empty reference annotations. This limitation may result in ineffective research of machine learning practitioners in designing and optimizing models. Dimensions of evaluating clinical value include consideration of the uncertainty of reference annotations, independence from reference annotation volume size, and evaluation of classification of empty reference annotations. We study how uncertain, small, and empty reference annotations influence the value of metrics for medical image segmentation on an in-house data set regardless of the model. We examine metrics behavior on the predictions of a standard deep learning framework in order to identify metrics with clinical value. We compare to a public benchmark data set (BraTS 2019) with a high-signal pathology and certain, larger, and no empty reference annotations. We may show machine learning practitioners, how uncertain, small, or empty reference annotations require a rethinking of the evaluation and optimizing procedures. The evaluation code was released to encourage further analysis of this topic. https://github.com/SophieOstmeier/UncertainSmallEmpty.git
IVNov 24, 2022
Non-inferiority of Deep Learning Acute Ischemic Stroke Segmentation on Non-Contrast CT Compared to Expert NeuroradiologistsSophie Ostmeier, Brian Axelrod, Benjamin F. J. Verhaaren et al.
To determine if a convolutional neural network (CNN) deep learning model can accurately segment acute ischemic changes on non-contrast CT compared to neuroradiologists. Non-contrast CT (NCCT) examinations from 232 acute ischemic stroke patients who were enrolled in the DEFUSE 3 trial were included in this study. Three experienced neuroradiologists independently segmented hypodensity that reflected the ischemic core on each scan. The neuroradiologist with the most experience (expert A) served as the ground truth for deep learning model training. Two additional neuroradiologists (experts B and C) segmentations were used for data testing. The 232 studies were randomly split into training and test sets. The training set was further randomly divided into 5 folds with training and validation sets. A 3-dimensional CNN architecture was trained and optimized to predict the segmentations of expert A from NCCT. The performance of the model was assessed using a set of volume, overlap, and distance metrics using non-inferiority thresholds of 20%, 3ml, and 3mm. The optimized model trained on expert A was compared to test experts B and C. We used a one-sided Wilcoxon signed-rank test to test for the non-inferiority of the model-expert compared to the inter-expert agreement. The final model performance for the ischemic core segmentation task reached a performance of 0.46+-0.09 Surface Dice at Tolerance 5mm and 0.47+-0.13 Dice when trained on expert A. Compared to the two test neuroradiologists the model-expert agreement was non-inferior to the inter-expert agreement, p < 0.05. The CNN accurately delineates the hypodense ischemic core on NCCT in acute ischemic stroke patients with an accuracy comparable to neuroradiologists.