Zhehua Mao

CV
h-index7
3papers
6citations
Novelty47%
AI Score36

3 Papers

3.6IVSep 25, 2024
Automated Surgical Skill Assessment in Endoscopic Pituitary Surgery using Real-time Instrument Tracking on a High-fidelity Bench-top Phantom

Adrito Das, Bilal Sidiqi, Laurent Mennillo et al.

Improved surgical skill is generally associated with improved patient outcomes, although assessment is subjective; labour-intensive; and requires domain specific expertise. Automated data driven metrics can alleviate these difficulties, as demonstrated by existing machine learning instrument tracking models in minimally invasive surgery. However, these models have been tested on limited datasets of laparoscopic surgery, with a focus on isolated tasks and robotic surgery. In this paper, a new public dataset is introduced, focusing on simulated surgery, using the nasal phase of endoscopic pituitary surgery as an exemplar. Simulated surgery allows for a realistic yet repeatable environment, meaning the insights gained from automated assessment can be used by novice surgeons to hone their skills on the simulator before moving to real surgery. PRINTNet (Pituitary Real-time INstrument Tracking Network) has been created as a baseline model for this automated assessment. Consisting of DeepLabV3 for classification and segmentation; StrongSORT for tracking; and the NVIDIA Holoscan SDK for real-time performance, PRINTNet achieved 71.9% Multiple Object Tracking Precision running at 22 Frames Per Second. Using this tracking output, a Multilayer Perceptron achieved 87% accuracy in predicting surgical skill level (novice or expert), with the "ratio of total procedure time to instrument visible time" correlated with higher surgical skill. This therefore demonstrates the feasibility of automated surgical skill assessment in simulated endoscopic pituitary surgery. The new publicly available dataset can be found here: https://doi.org/10.5522/04/26511049.

3.6CVOct 31, 2025
MambaNetLK: Enhancing Colonoscopy Point Cloud Registration with Mamba

Linzhe Jiang, Jiayuan Huang, Sophia Bano et al.

Accurate 3D point cloud registration underpins reliable image-guided colonoscopy, directly affecting lesion localization, margin assessment, and navigation safety. However, biological tissue exhibits repetitive textures and locally homogeneous geometry that cause feature degeneracy, while substantial domain shifts between pre-operative anatomy and intra-operative observations further degrade alignment stability. To address these clinically critical challenges, we introduce a novel 3D registration method tailored for endoscopic navigation and a high-quality, clinically grounded dataset to support rigorous and reproducible benchmarking. We introduce C3VD-Raycasting-10k, a large-scale benchmark dataset with 10,014 geometrically aligned point cloud pairs derived from clinical CT data. We propose MambaNetLK, a novel correspondence-free registration framework, which enhances the PointNetLK architecture by integrating a Mamba State Space Model (SSM) as a cross-modal feature extractor. As a result, the proposed framework efficiently captures long-range dependencies with linear-time complexity. The alignment is achieved iteratively using the Lucas-Kanade algorithm. On the clinical dataset, C3VD-Raycasting-10k, MambaNetLK achieves the best performance compared with the state-of-the-art methods, reducing median rotation error by 56.04% and RMSE translation error by 26.19% over the second-best method. The model also demonstrates strong generalization on ModelNet40 and superior robustness to initial pose perturbations. MambaNetLK provides a robust foundation for 3D registration in surgical navigation. The combination of a globally expressive SSM-based feature extractor and a large-scale clinical dataset enables more accurate and reliable guidance systems in minimally invasive procedures like colonoscopy.

3.7CVMay 21, 2021Code
DSR: Direct Simultaneous Registration for Multiple 3D Images

Zhehua Mao, Liang Zhao, Shoudong Huang et al.

This paper presents a novel algorithm named Direct Simultaneous Registration (DSR) that registers a collection of 3D images in a simultaneous fashion without specifying any reference image, feature extraction and matching, or information loss or reuse. The algorithm optimizes the global poses of local image frames by maximizing the similarity between a predefined panoramic image and local images. Although we formulate the problem as a Direct Bundle Adjustment (DBA) that jointly optimizes the poses of local frames and the intensities of the panoramic image, by investigating the independence of pose estimation from the panoramic image in the solving process, DSR is proposed to solve the poses only and proved to be able to obtain the same optimal poses as DBA. The proposed method is particularly suitable for the scenarios where distinct features are not available, such as Transesophageal Echocardiography (TEE) images. DSR is evaluated by comparing it with four widely used methods via simulated and in-vivo 3D TEE images. It is shown that the proposed method outperforms these four methods in terms of accuracy and requires much fewer computational resources than the state-of-the-art accumulated pairwise estimates (APE).