CVOct 30, 2023
Dynamic Gaussian Splatting from Markerless Motion Capture can Reconstruct Infants MovementsR. James Cotton, Colleen Peyton
Easy access to precise 3D tracking of movement could benefit many aspects of rehabilitation. A challenge to achieving this goal is that while there are many datasets and pretrained algorithms for able-bodied adults, algorithms trained on these datasets often fail to generalize to clinical populations including people with disabilities, infants, and neonates. Reliable movement analysis of infants and neonates is important as spontaneous movement behavior is an important indicator of neurological function and neurodevelopmental disability, which can help guide early interventions. We explored the application of dynamic Gaussian splatting to sparse markerless motion capture (MMC) data. Our approach leverages semantic segmentation masks to focus on the infant, significantly improving the initialization of the scene. Our results demonstrate the potential of this method in rendering novel views of scenes and tracking infant movements. This work paves the way for advanced movement analysis tools that can be applied to diverse clinical populations, with a particular emphasis on early detection in infants.
8.8CVMay 16
Markerless Motion Capture for Biomechanical Whole-Body Kinematic Estimation in InfantsDivya Joshi, J. D. Peiffer, Colleen Peyton et al.
arly identification of motor impairment in infancy relies on expert visual assessment of spontaneous movement, motivating the development of automated, objective alternatives. One promising approach is using computer vision, which benefits from high quality pose estimation from video. In this study, we systematically evaluated three state-of-the-art pose estimation frameworks (MeTRAbs-ACAE, SAM 3D Body, and Sapiens) on 100 videos over 13 sessions of 8 infants recorded with a multi-view markerless motion capture system. We quantified keypoint detection accuracy using reprojection error, geometric consistency, and Procrustes-aligned 3D position error, and demonstrated proof-of-concept for fitting an inverse kinematic framework to infant data. While Sapiens achieved the lowest reprojection error and highest geometric consistency of the methods evaluated (22.8 pixels and 0.82, respectively), SAM 3D Body provided the most comprehensive 3D information for kinematic reconstruction with Procrustes-aligned position errors of 19 to 28 mm. We demonstrate in a case comparison example that biomechanical models fit to SAM 3D estimates distinguish representative movement patterns in infants related to motor development, as identified by a clinical expert. Together, these findings highlight both the promise and current limitations of 3D pose estimation for infant biomechanics and establish preliminary groundwork for scalable, video-based assessment of early motor development.