Huan Xie

SY
3papers
15citations
Novelty42%
AI Score39

3 Papers

LGOct 22, 2023
A global product of fine-scale urban building height based on spaceborne lidar

Xiao Ma, Guang Zheng, Chi Xu et al.

Characterizing urban environments with broad coverages and high precision is more important than ever for achieving the UN's Sustainable Development Goals (SDGs) as half of the world's populations are living in cities. Urban building height as a fundamental 3D urban structural feature has far-reaching applications. However, so far, producing readily available datasets of recent urban building heights with fine spatial resolutions and global coverages remains a challenging task. Here, we provide an up-to-date global product of urban building heights based on a fine grid size of 150 m around 2020 by combining the spaceborne lidar instrument of GEDI and multi-sourced data including remotely sensed images (i.e., Landsat-8, Sentinel-2, and Sentinel-1) and topographic data. Our results revealed that the estimated method of building height samples based on the GEDI data was effective with 0.78 of Pearson's r and 3.67 m of RMSE in comparison to the reference data. The mapping product also demonstrated good performance as indicated by its strong correlation with the reference data (i.e., Pearson's r = 0.71, RMSE = 4.60 m). Compared with the currently existing products, our global urban building height map holds the ability to provide a higher spatial resolution (i.e., 150 m) with a great level of inherent details about the spatial heterogeneity and flexibility of updating using the GEDI samples as inputs. This work will boost future urban studies across many fields including climate, environmental, ecological, and social sciences.

89.3SYMar 26
Multi-Swing Transient Stability of Synchronous Generators and IBR Combined Generation Systems

Songhao Yang, Bingfang Li, Zhiguo Hao et al.

In traditional views, the build-up of accelerating energy during faults can cause the well-known first-swing angle instability in synchronous generators (SGs). Interestingly, this letter presents a new insight that the accumulation of decelerating energy due to the low voltage ride-through (LVRT) and recovery control of grid-following inverter-based resources (GFL-IBRs), might also result in transient angle instability in SGs. The transient energy accumulated during angle-decreasing swing transforms into the acceleration energy of the subsequent swing, hence such phenomena often manifest as multi-swing instability. Both theoretical analysis and simulation support these findings.

73.9SYMar 26
Dominant Transient Stability of the Co-located PLL-Based Grid-Following Renewable Plant and Synchronous Condenser Systems

Bingfang Li, Songhao Yang, Qinglan Wang et al.

Deploying synchronous condensers (SynCons) near grid-following renewable energy sources (GFLRs) is an effective and increasingly adopted strategy for grid support. However, the potential transient instability risks in such configurations remain an open research question. This study investigates the mechanism of dominant synchronization instability source transition upon SynCon integration and proposes a straightforward approach to enhance system stability by leveraging their interactive characteristics. Firstly, a dual-timescale decoupling model is established, partitioning the system into a fast subsystem representing phase-locked loop (PLL) dynamics and a slow subsystem characterizing SynCon rotor dynamics. The study then examines the influence of SynCons on the transient stability of nearby PLLs and their own inherent stability. The study shows that SynCon's voltage-source characteristics and its time-scale separation from PLL dynamics can significantly enhance the PLL's stability boundary and mitigate non-coherent coupling effects among multiple GFLRs. However, the dominant instability source shifts from the fast-time-scale PLL to the slow-time-scale SynCon after SynCon integration. Crucially, this paper demonstrates that the damping effect of PLL control can also be transferred from the fast to the slow time scale, allowing well-tuned PLL damping to suppress SynCon rotor acceleration. Consequently, by utilizing SynCon's inherent support capability and a simple PLL damping loop, the transient stability of the co-located system can be significantly enhanced. These conclusions are validated using a converter controller-based Hardware-in-the-Loop (CHIL) platform.