Weixi Yi

CV
h-index56
6papers
18citations
Novelty57%
AI Score51

6 Papers

CVAug 22, 2023
Boundary-RL: Reinforcement Learning for Weakly-Supervised Prostate Segmentation in TRUS Images

Weixi Yi, Vasilis Stavrinides, Zachary M. C. Baum et al.

We propose Boundary-RL, a novel weakly supervised segmentation method that utilises only patch-level labels for training. We envision the segmentation as a boundary detection problem, rather than a pixel-level classification as in previous works. This outlook on segmentation may allow for boundary delineation under challenging scenarios such as where noise artefacts may be present within the region-of-interest (ROI) boundaries, where traditional pixel-level classification-based weakly supervised methods may not be able to effectively segment the ROI. Particularly of interest, ultrasound images, where intensity values represent acoustic impedance differences between boundaries, may also benefit from the boundary delineation approach. Our method uses reinforcement learning to train a controller function to localise boundaries of ROIs using a reward derived from a pre-trained boundary-presence classifier. The classifier indicates when an object boundary is encountered within a patch, as the controller modifies the patch location in a sequential Markov decision process. The classifier itself is trained using only binary patch-level labels of object presence, which are the only labels used during training of the entire boundary delineation framework, and serves as a weak signal to inform the boundary delineation. The use of a controller function ensures that a sliding window over the entire image is not necessary. It also prevents possible false-positive or -negative cases by minimising number of patches passed to the boundary-presence classifier. We evaluate our proposed approach for a clinically relevant task of prostate gland segmentation on trans-rectal ultrasound images. We show improved performance compared to other tested weakly supervised methods, using the same labels e.g., multiple instance learning.

CVMar 4
ProFound: A moderate-sized vision foundation model for multi-task prostate imaging

Yipei Wang, Yinsong Xu, Weixi Yi et al.

Many diagnostic and therapeutic clinical tasks for prostate cancer increasingly rely on multi-parametric MRI. Automating these tasks is challenging because they necessitate expert interpretations, which are difficult to scale to capitalise on modern deep learning. Although modern automated systems achieve expert-level performance in isolated tasks, their general clinical utility remains limited by the requirement of large task-specific labelled datasets. In this paper, we present ProFound, a domain-specialised vision foundation model for volumetric prostate mpMRI. ProFound is pre-trained using several variants of self-supervised approaches on a diverse, multi-institutional collection of 5,000 patients, with a total of over 22,000 unique 3D MRI volumes (over 1,800,000 2D image slices). We conducted a systematic evaluation of ProFound across a broad spectrum of $11$ downstream clinical tasks on over 3,000 independent patients, including prostate cancer detection, Gleason grading, lesion localisation, gland volume estimation, zonal and surrounding structure segmentation. Experimental results demonstrate that finetuned ProFound consistently outperforms or remains competitive with state-of-the-art specialised models and existing medical vision foundation models trained/finetuned on the same data.

IVMay 31, 2025Code
A versatile foundation model for cine cardiac magnetic resonance image analysis tasks

Yunguan Fu, Wenjia Bai, Weixi Yi et al.

Here we present a versatile foundation model that can perform a range of clinically-relevant image analysis tasks, including segmentation, landmark localisation, diagnosis, and prognostication. A multi-view convolution-transformer masked autoencoder, named as CineMA, was trained on 15 million cine images from 74,916 subjects. The model was validated on multiple image analysis tasks and compared to existing models on >4,500 images from eight independent datasets with diverse population characteristics, representing the largest benchmark study for cine CMR so far. CineMA consistently outperformed conventional convolutional neural networks (CNNs) in delineating ventricular boundaries and estimating ejection fraction, a key measure of cardiac function. The improved performance was preserved, even when the model only used half of fine-tuning data. CineMA also surpassed CNNs in disease detection and matched their performance in long-axis function measurement. Interestingly, we found that CineMA can also detect cardiac changes in systemic diseases, such as diabetes, hypertension and cancer, and can also predict mortality. Finally, we assessed model fairness and demonstrated consistent model performance across demographic subgroups. These findings highlight CineMA's accuracy, learning efficiency, adaptability, and fairness, underscoring its potential as a foundation model for automated cardiac image analysis to support clinical workflow and cardiovascular research. All training and inference code and models are made publicly available at https://github.com/mathpluscode/CineMA.

CVJul 17, 2025Code
Analysis of Image-and-Text Uncertainty Propagation in Multimodal Large Language Models with Cardiac MR-Based Applications

Yucheng Tang, Yunguan Fu, Weixi Yi et al.

Multimodal large language models (MLLMs) can process and integrate information from multimodality sources, such as text and images. However, interrelationship among input modalities, uncertainties due to individual uni-modal data and potential clinical applications following such an uncertainty decomposition are yet fully understood in the context of large-scale MLLMs. In this work, we propose a multimodal uncertainty propagation model (MUPM) based on uncertainty propagation, to characterise the relationship among the uncertainties arising from image-only, text-only, and joint image-text variations in MLLM inputs. Using real clinical data consisting of cardiac MR scans and digital health records, we describe that MUPMs can be optimised robustly with a few samples. We then show that the fitted MUPMs are generalisable across different input data distributions and, perhaps surprisingly, across different downstream tasks. Such a transferability may be explained by the shared pretraining, comparatively light MLLM fine-tuning, along with the low-dimensional nature of the MUPMs. More importantly, this learned transferability, quantifying the relationship between these uncertainties, led to direct clinical applications in which uncertainties may be estimated and thus analysed robustly for varying data or even a novel set of cardiac disease prediction tasks. In addition, we show experimentally the efficiency in multimodal data required for estimating the overall uncertainty and its ability to identify redundant factors, both of which are considered practical yet clinically useful applications with the proposed MUPMs. Codes are available at https://github.com/yucheng722/MUPM.

IVNov 11, 2024
T2-Only Prostate Cancer Prediction by Meta-Learning from Bi-Parametric MR Imaging

Weixi Yi, Yipei Wang, Natasha Thorley et al.

Current imaging-based prostate cancer diagnosis requires both MR T2-weighted (T2w) and diffusion-weighted imaging (DWI) sequences, with additional sequences for potentially greater accuracy improvement. However, measuring diffusion patterns in DWI sequences can be time-consuming, prone to artifacts and sensitive to imaging parameters. While machine learning (ML) models have demonstrated radiologist-level accuracy in detecting prostate cancer from these two sequences, this study investigates the potential of ML-enabled methods using only the T2w sequence as input during inference time. We first discuss the technical feasibility of such a T2-only approach, and then propose a novel ML formulation, where DWI sequences - readily available for training purposes - are only used to train a meta-learning model, which subsequently only uses T2w sequences at inference. Using multiple datasets from more than 3,000 prostate cancer patients, we report superior or comparable performance in localising radiologist-identified prostate cancer using our proposed T2-only models, compared with alternative models using T2-only or both sequences as input. Real patient cases are presented and discussed to demonstrate, for the first time, the exclusively true-positive cases from models with different input sequences.

31.0CVApr 1
Maximizing T2-Only Prostate Cancer Localization from Expected Diffusion Weighted Imaging

Weixi Yi, Yipei Wang, Wen Yan et al.

Multiparametric MRI is increasingly recommended as a first-line noninvasive approach to detect and localize prostate cancer, requiring at minimum diffusion-weighted (DWI) and T2-weighted (T2w) MR sequences. Early machine learning attempts using only T2w images have shown promising diagnostic performance in segmenting radiologist-annotated lesions. Such uni-modal T2-only approaches deliver substantial clinical benefits by reducing costs and expertise required to acquire other sequences. This work investigates an arguably more challenging application using only T2w at inference, but to localize individual cancers based on independent histopathology labels. We formulate DWI images as a latent modality (readily available during training) to classify cancer presence at local Barzell zones, given only T2w images as input. In the resulting expectation-maximization algorithm, a latent modality generator (implemented using a flow matching-based generative model) approximates the latent DWI image posterior distribution in the E-steps, while in M-steps a cancer localizer is simultaneously optimized with the generative model to maximize the expected likelihood of cancer presence. The proposed approach provides a novel theoretical framework for learning from a privileged DWI modality, yielding superior cancer localization performance compared to approaches that lack training DWI images or existing frameworks for privileged learning and incomplete modalities. The proposed T2-only methods perform competitively or better than baseline methods using multiple input sequences (e.g., improving the patient-level F1 score by 14.4\% and zone-level QWK by 5.3\% over the T2w+DWI baseline). We present quantitative evaluations using internal and external datasets from 4,133 prostate cancer patients with histopathology-verified labels.