Muhammed Furkan Dasdelen

CV
h-index69
4papers
243citations
Novelty61%
AI Score57

4 Papers

CVMay 28Code
Genetically Aligned Patient Representations Improve Hematological Diagnosis

Muhammed Furkan Dasdelen, Fatih Ozlugedik, Ilaria Looser et al.

Multimodal alignment of histopathology encoders with transcriptomic and genomic data has been shown to significantly improve performance in downstream diagnostic tasks. Hematological cytology is unique in that visual single-cell evaluation is often paired with cytogenetics and molecular genetics for blood cancer diagnosis. In this study, we present a framework to align single white blood cell images with chromosomal aberrations (karyotype) and somatic mutations from targeted gene panels. Our training strategy follows a two-stage approach: (i) self-supervised, vision-only pretraining of a transformer aggregator using an iBOT head on a cohort of over 1500 patients, and (ii) genetic alignment via supervised contrastive loss on acute myeloid leukemia patients. Our genetically aligned patient encoder improves hematological diagnostic tasks, outperforming slide-level histopathology foundation models. Additionally, the model provides off-the-shelf retrieval capabilities for diseases and genetic alterations. Incorporating genetic data into patient encoders increases the quality of patient representations, providing a framework that aligns with clinical diagnostic workflows and paves the way for future multimodal hematology-specific AI. The code and model weights are available at https://github.com/marrlab/GenBloom.

CVMar 26, 2024Code
Developing Generalist Foundation Models from a Multimodal Dataset for 3D Computed Tomography

Ibrahim Ethem Hamamci, Sezgin Er, Chenyu Wang et al.

Advancements in medical imaging AI, particularly in 3D imaging, have been limited due to the scarcity of comprehensive datasets. We introduce CT-RATE, a public dataset that pairs 3D medical images with corresponding textual reports. CT-RATE comprises 25,692 non-contrast 3D chest CT scans from 21,304 unique patients. Each scan is accompanied by its corresponding radiology report. Leveraging CT-RATE, we develop CT-CLIP, a CT-focused contrastive language-image pretraining framework designed for broad applications without the need for task-specific training. We demonstrate how CT-CLIP can be used in multi-abnormality detection and case retrieval, and outperforms state-of-the-art fully supervised models across all key metrics. By combining CT-CLIP's vision encoder with a pretrained large language model, we create CT-CHAT, a vision-language foundational chat model for 3D chest CT volumes. Finetuned on over 2.7 million question-answer pairs derived from the CT-RATE dataset, CT-CHAT underscores the necessity for specialized methods in 3D medical imaging. Collectively, the open-source release of CT-RATE, CT-CLIP, and CT-CHAT not only addresses critical challenges in 3D medical imaging but also lays the groundwork for future innovations in medical AI and improved patient care.

CVJul 16, 2025Code
CytoSAE: Interpretable Cell Embeddings for Hematology

Muhammed Furkan Dasdelen, Hyesu Lim, Michele Buck et al.

Sparse autoencoders (SAEs) emerged as a promising tool for mechanistic interpretability of transformer-based foundation models. Very recently, SAEs were also adopted for the visual domain, enabling the discovery of visual concepts and their patch-wise attribution to tokens in the transformer model. While a growing number of foundation models emerged for medical imaging, tools for explaining their inferences are still lacking. In this work, we show the applicability of SAEs for hematology. We propose CytoSAE, a sparse autoencoder which is trained on over 40,000 peripheral blood single-cell images. CytoSAE generalizes to diverse and out-of-domain datasets, including bone marrow cytology, where it identifies morphologically relevant concepts which we validated with medical experts. Furthermore, we demonstrate scenarios in which CytoSAE can generate patient-specific and disease-specific concepts, enabling the detection of pathognomonic cells and localized cellular abnormalities at the patch level. We quantified the effect of concepts on a patient-level AML subtype classification task and show that CytoSAE concepts reach performance comparable to the state-of-the-art, while offering explainability on the sub-cellular level. Source code and model weights are available at https://github.com/dynamical-inference/cytosae.

CVMay 25, 2023Code
GenerateCT: Text-Conditional Generation of 3D Chest CT Volumes

Ibrahim Ethem Hamamci, Sezgin Er, Anjany Sekuboyina et al.

GenerateCT, the first approach to generating 3D medical imaging conditioned on free-form medical text prompts, incorporates a text encoder and three key components: a novel causal vision transformer for encoding 3D CT volumes, a text-image transformer for aligning CT and text tokens, and a text-conditional super-resolution diffusion model. Without directly comparable methods in 3D medical imaging, we benchmarked GenerateCT against cutting-edge methods, demonstrating its superiority across all key metrics. Importantly, we evaluated GenerateCT's clinical applications in a multi-abnormality classification task. First, we established a baseline by training a multi-abnormality classifier on our real dataset. To further assess the model's generalization to external data and performance with unseen prompts in a zero-shot scenario, we employed an external set to train the classifier, setting an additional benchmark. We conducted two experiments in which we doubled the training datasets by synthesizing an equal number of volumes for each set using GenerateCT. The first experiment demonstrated an 11% improvement in the AP score when training the classifier jointly on real and generated volumes. The second experiment showed a 7% improvement when training on both real and generated volumes based on unseen prompts. Moreover, GenerateCT enables the scaling of synthetic training datasets to arbitrary sizes. As an example, we generated 100,000 3D CTs, fivefold the number in our real set, and trained the classifier exclusively on these synthetic CTs. Impressively, this classifier surpassed the performance of the one trained on all available real data by a margin of 8%. Last, domain experts evaluated the generated volumes, confirming a high degree of alignment with the text prompt. Access our code, model weights, training data, and generated data at https://github.com/ibrahimethemhamamci/GenerateCT