Eduardo Piedad

h-index9
4papers
500citations

4 Papers

1.2SPAug 19, 2024
Deep Learning-based Machine Condition Diagnosis using Short-time Fourier Transformation Variants

Eduardo Jr Piedad, Zherish Galvin Mayordo, Eduardo Prieto-Araujo et al.

In motor condition diagnosis, electrical current signature serves as an alternative feature to vibration-based sensor data, which is a more expensive and invasive method. Machine learning (ML) techniques have been emerging in diagnosing motor conditions using only motor phase current signals. This study converts time-series motor current signals to time-frequency 2D plots using Short-time Fourier Transform (STFT) methods. The motor current signal dataset consists of 3,750 sample points with five classes - one healthy and four synthetically-applied motor fault conditions, and with five loading conditions: 0, 25, 50, 75, and 100%. Five transformation methods are used on the dataset: non-overlap and overlap STFTs, non-overlap and overlap realigned STFTs, and synchrosqueezed STFT. Then, deep learning (DL) models based on the previous Convolutional Neural Network (CNN) architecture are trained and validated from generated plots of each method. The DL models of overlap-STFT, overlap R-STFT, non-overlap STFT, non-overlap R-STFT, and synchrosqueezed-STFT performed exceptionally with an average accuracy of 97.65, 96.03, 96.08, 96.32, and 88.27%, respectively. Four methods outperformed the previous best ML method with 93.20% accuracy, while all five outperformed previous 2D-plot-based methods with accuracy of 80.25, 74.80, and 82.80%, respectively, using the same dataset, same DL architecture, and validation steps.

1.2SPAug 19, 2024
Exploring Wavelet Transformations for Deep Learning-based Machine Condition Diagnosis

Eduardo Jr Piedad, Christian Ainsley Del Rosario, Eduardo Prieto-Araujo et al.

Deep learning (DL) strategies have recently been utilized to diagnose motor faults by simply analyzing motor phase current signals, offering a less costly and non-intrusive alternative to vibration sensors. This research transforms these time-series current signals into time-frequency 2D representations via Wavelet Transform (WT). The dataset for motor current signals includes 3,750 data points across five categories: one representing normal conditions and four representing artificially induced faults, each under five different load conditions: 0, 25, 50, 75, and 100%. The study employs five WT-based techniques: WT-Amor, WT-Bump, WT-Morse, WSST-Amor, and WSST-Bump. Subsequently, five DL models adopting prior Convolutional Neural Network (CNN) architecture were developed and tested using the transformed 2D plots from each method. The DL models for WT-Amor, WT-Bump, and WT-Morse showed remarkable effectiveness with peak model accuracy of 90.93, 89.20, and 93.73%, respectively, surpassing previous 2D-image-based methods that recorded accuracy of 80.25, 74.80, and 82.80% respectively using the identical dataset and validation protocol. Notably, the WT-Morse approach slightly exceeded the formerly highest ML technique, achieving a 93.20% accuracy. However, the two WSST methods that utilized synchrosqueezing techniques faced difficulty accurately classifying motor faults. The performance of Wavelet-based deep learning methods offers a compelling alternative for machine condition monitoring.

SPJun 26
Distributed Air-Gap Flux and Rotor-Current Fusion for Operating-Regime Identification in a 10-MW Kaplan Hydrogenerator

Eduardo Jr Piedad, Rafel Roig, Xavier Escaler et al.

Reliable monitoring of hydroelectric generators requires descriptors that capture both electrical loading and electromagnetic field behavior. This work investigates operating-regime identification in the Porjus U9 10-MW Kaplan hydrogenerator using synchronized measurements from ten stator-mounted Hall probes and six rotor-current channels. Seven steady guide-vane-opening settings are considered, and each 300s record is divided into 1s windows. The resulting windows are represented by spatial Fourier descriptors of the circumferential air-gap field, probe-wise temporal flux indicators, and channel-wise RMS rotor-current features. Correlation analysis and principal component analysis are used to examine how the feature groups vary with the operating point, and Random Forest, radial-basis-function support vector classification, and multilayer perceptron models are evaluated for supervised identification of the guide-vane-opening state. The analysis shows that RMS rotor-current features mainly track the loading axis, while the magnetic-flux features reveal complementary information associated with spatial imbalance, waveform distortion, and weak low-frequency modulation. Spatial descriptors alone provide limited separability, yielding test accuracies below 27%, whereas rotor-current features alone reach about 84-85%. Combining flux and current information gives the most discriminative representation; the SVC-RBF model achieves 99.5% test accuracy and macro-F1 score. The results indicate that distributed air-gap magnetic sensing, when fused with rotor-current measurements, can support accurate and interpretable data-driven monitoring of Kaplan hydrogenerator operating regimes.

3.7SPJun 14
Early Anomaly-Onset Detection based on Wigner--Ville Distribution Slice Spectra: A Transmission-Grid Test Case

Eduardo Jr Piedad, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt

Operational disturbance monitoring in power networks requires decisions to be made from waveform windows as they arrive, rather than from completed records after the event. This study evaluates full-vector Wigner--Ville Distribution Slice (WVDS) spectra for sequential anomaly-onset detection in high-voltage grid-voltage waveforms. The approach keeps the bilinear midpoint interaction structure of the Wigner--Ville distribution and represents each 128-sample voltage window by a 128-dimensional slice spectrum, avoiding manually selected fault-frequency markers. WVDS is used with a baseline-normalized deviation (BND) score and is compared against the BND of Fast Fourier Transform (FFT-BND), raw-window autoencoders, FFT autoencoders, and WVDS autoencoders under the same thresholding and three-window persistence rule. A synthetic autoencoder--clustering teacher is used to select RTE fault records that start from an initially normal region and then transition to anomalous behavior. On the filtered test set, FFT-BND achieves the highest sensitivity, whereas WVDS-BND provides the lowest false-alarm operating point, reducing record-level pre-onset false alarms to 0.69%. The autoencoder comparison follows the same selectivity pattern: WVDS reconstruction decreases false alarms relative to FFT reconstruction but misses more examples. The results indicate that preserved WVD cross-term information can form a selective representation for online grid-waveform anomaly monitoring when false alarms are costly.