ROMar 6
SuperSuit: An Isomorphic Bimodal Interface for Scalable Mobile ManipulationTongqing Chen, Hang Wu, Jiasen Wang et al.
High-quality, long-horizon demonstrations are essential for embodied AI, yet acquiring such data for tightly coupled wheeled mobile manipulators remains a fundamental bottleneck. Unlike fixed-base systems, mobile manipulators require continuous coordination between $SE(2)$ locomotion and precise manipulation, exposing limitations in existing teleoperation and wearable interfaces. We present \textbf{SuperSuit}, a bimodal data acquisition framework that supports both robot-in-the-loop teleoperation and active demonstration under a shared kinematic interface. Both modalities produce structurally identical joint-space trajectories, enabling direct data mixing without modifying downstream policies. For locomotion, SuperSuit maps natural human stepping to continuous planar base velocities, eliminating discrete command switches. For manipulation, it employs a strictly isomorphic wearable arm in both modes, while policy training is formulated in a shift-invariant delta-joint representation to mitigate calibration offsets and structural compliance without inverse kinematics. Real-world experiments on long-horizon mobile manipulation tasks show 2.6$\times$ higher demonstration throughput in active mode compared to a teleoperation baseline, comparable policy performance when substituting teleoperation data with active demonstrations at fixed dataset size, and monotonic performance improvement as active data volume increases. These results indicate that consistent kinematic representations across collection modalities enable scalable data acquisition for long-horizon mobile manipulation.
ROJun 7, 2021
Robotic Electrospinning Actuated by Non-Circular Joint Continuum Manipulator for Endoluminal TherapyZicong Wu, Chuqian Lou, Zhu Jin et al.
Electrospinning has exhibited excellent benefits to treat the trauma for tissue engineering due to its produced micro/nano fibrous structure. It can effectively adhere to the tissue surface for long-term continuous therapy. This paper develops a robotic electrospinning platform for endoluminal therapy. The platform consists of a continuum manipulator, the electrospinning device, and the actuation unit. The continuum manipulator has two bending sections to facilitate the steering of the tip needle for a controllable spinning direction. Non-circular joint profile is carefully designed to enable a constant length of the centreline of a continuum manipulator for stable fluid transmission inside it. Experiments are performed on a bronchus phantom, and the steering ability and bending limitation in each direction are also investigated. The endoluminal electrospinning is also fulfilled by a trajectory following and points targeting experiments. The effective adhesive area of the produced fibre is also illustrated. The proposed robotic electrospinning shows its feasibility to precisely spread more therapeutic drug to construct fibrous structure for potential endoluminal treatment.
APP-PHJun 11, 2020
FBG-Based Triaxial Force Sensor Integrated with an Eccentrically Configured Imaging Probe for Endoluminal Optical BiopsyZicong Wu, Anzhu Gao, Ning Liu et al.
Accurate force sensing is important for endoluminal intervention in terms of both safety and lesion targeting. This paper develops an FBG-based force sensor for robotic bronchoscopy by configuring three FBG sensors at the lateral side of a conical substrate. It allows a large and eccentric inner lumen for the interventional instrument, enabling a flexible imaging probe inside to perform optical biopsy. The force sensor is embodied with a laser-profiled continuum robot and thermo drift is fully compensated by three temperature sensors integrated on the circumference surface of the sensor substrate. Different decoupling approaches are investigated, and nonlinear decoupling is adopted based on the cross-validation SVM and a Gaussian kernel function, achieving an accuracy of 10.58 mN, 14.57 mN and 26.32 mN along X, Y and Z axis, respectively. The tissue test is also investigated to further demonstrate the feasibility of the developed triaxial force sensor