Christoph S. Garbe

CV
h-index23
3papers
23citations
Novelty30%
AI Score21

3 Papers

2.6CVApr 11, 2022
An Optimal Experimental Design Approach for Light Configurations in Photometric Stereo

Hamza Gardi, Sebastian F. Walter, Christoph S. Garbe

This paper presents a technique for finding the surface normal of an object from a set of images obtained under different lighting positions. The method presented is based on the principles of Photometric Stereo (PS) combined with Optimum Experimental Design (OED) and Parameter Estimation (PE). Unclear by the approach of photometric stereo, and many models based thereon, is how to position the light sources. So far, this is done by using heuristic approaches this leads to suboptimal and non-data driven positioning of the light sources. But what if the optimal positions of the light sources are calculated for photometric stereo? To this end, in this contribution, the effect of positioning the light sources on the quality of the normal vector for PS is evaluated. Furthermore, a new approach in this direction is derived and formulated. For the calculation of the surface normal of a Lambertian surface, the approach based on calibrated photometric stereo; for the estimation the optimal position of the light sources the approach is premised on parameter estimation and optimum experimental design. The approach is tested using synthetic and real-data. Based on results it can be seen that the surface normal estimated with the new method is more detailed than with conventional methods.

1.8CVJan 4, 2019Code
Reference Setup for Quantitative Comparison of Segmentation Techniques for Short Glass Fiber CT Data

Tomasz Konopczyński, Jitendra Rathore, Thorben Kröger et al.

Comparing different algorithms for segmenting glass fibers in industrial computed tomography (CT) scans is difficult due to the absence of a standard reference dataset. In this work, we introduce a set of annotated scans of short-fiber reinforced polymers (SFRP) as well as synthetically created CT volume data together with the evaluation metrics. We suggest both the metrics and this data set as a reference for studying the performance of different algorithms. The real scans were acquired by a Nikon MCT225 X-ray CT system. The simulated scans were created by the use of an in-house computational model and third-party commercial software. For both types of data, corresponding ground truth annotations have been prepared, including hand annotations for the real scans and STL models for the synthetic scans. Additionally, a Hessian-based Frangi vesselness filter for fiber segmentation has been implemented and open-sourced to serve as a reference for comparisons.

1.8CVJan 4, 2019
Fully Convolutional Deep Network Architectures for Automatic Short Glass Fiber Semantic Segmentation from CT scans

Tomasz Konopczyński, Danish Rathore, Jitendra Rathore et al.

We present the first attempt to perform short glass fiber semantic segmentation from X-ray computed tomography volumetric datasets at medium (3.9 μm isotropic) and low (8.3 μm isotropic) resolution using deep learning architectures. We performed experiments on both synthetic and real CT scans and evaluated deep fully convolutional architectures with both 2D and 3D kernels. Our artificial neural networks outperform existing methods at both medium and low resolution scans.