Step-Video-T2V Technical Report: The Practice, Challenges, and Future of Video Foundation ModelGuoqing Ma, Haoyang Huang, Kun Yan et al.
We present Step-Video-T2V, a state-of-the-art text-to-video pre-trained model with 30B parameters and the ability to generate videos up to 204 frames in length. A deep compression Variational Autoencoder, Video-VAE, is designed for video generation tasks, achieving 16x16 spatial and 8x temporal compression ratios, while maintaining exceptional video reconstruction quality. User prompts are encoded using two bilingual text encoders to handle both English and Chinese. A DiT with 3D full attention is trained using Flow Matching and is employed to denoise input noise into latent frames. A video-based DPO approach, Video-DPO, is applied to reduce artifacts and improve the visual quality of the generated videos. We also detail our training strategies and share key observations and insights. Step-Video-T2V's performance is evaluated on a novel video generation benchmark, Step-Video-T2V-Eval, demonstrating its state-of-the-art text-to-video quality when compared with both open-source and commercial engines. Additionally, we discuss the limitations of current diffusion-based model paradigm and outline future directions for video foundation models. We make both Step-Video-T2V and Step-Video-T2V-Eval available at https://github.com/stepfun-ai/Step-Video-T2V. The online version can be accessed from https://yuewen.cn/videos as well. Our goal is to accelerate the innovation of video foundation models and empower video content creators.
14.4CVJun 16, 2025
PRISM2: Unlocking Multi-Modal General Pathology AI with Clinical DialogueEugene Vorontsov, George Shaikovski, Adam Casson et al.
Recent rapid progress in the field of computational pathology has been enabled by foundation models. These models are beginning to move beyond encoding image patches towards whole-slide understanding but their clinical utility remains limited. In this work, we present PRISM2, a multimodal slide-level foundation model trained on data from 700,000 diagnostic specimen-report pairs, the largest vision (2.3 million whole slide images) and language (14M question-answer pairs) histopathology dataset to date. By learning through clinical-dialogue supervision, PRISM2 aligns histomorphologic features with the language of diagnostic reasoning, producing slide-level representations that support both direct diagnostic question-answering and transferable embeddings for downstream tasks. Without additional training, PRISM2 matches or exceeds the cancer-detection performance of clinical-grade products. This is observed without loss of generality on other tasks, where PRISM2 achieves top performance. Finally, using survival prediction as the example, we show that task-specific finetuning with a large dataset can outperform task-specific models, further improving performance. These results demonstrate how language-supervised pretraining provides a scalable, clinically grounded signal for learning generalizable pathology representations, bridging human diagnostic reasoning and foundation-model performance.
19.5IVApr 2, 2020
Automated Quantification of CT Patterns Associated with COVID-19 from Chest CTShikha Chaganti, Abishek Balachandran, Guillaume Chabin et al.
Purpose: To present a method that automatically segments and quantifies abnormal CT patterns commonly present in coronavirus disease 2019 (COVID-19), namely ground glass opacities and consolidations. Materials and Methods: In this retrospective study, the proposed method takes as input a non-contrasted chest CT and segments the lesions, lungs, and lobes in three dimensions, based on a dataset of 9749 chest CT volumes. The method outputs two combined measures of the severity of lung and lobe involvement, quantifying both the extent of COVID-19 abnormalities and presence of high opacities, based on deep learning and deep reinforcement learning. The first measure of (PO, PHO) is global, while the second of (LSS, LHOS) is lobewise. Evaluation of the algorithm is reported on CTs of 200 participants (100 COVID-19 confirmed patients and 100 healthy controls) from institutions from Canada, Europe and the United States collected between 2002-Present (April, 2020). Ground truth is established by manual annotations of lesions, lungs, and lobes. Correlation and regression analyses were performed to compare the prediction to the ground truth. Results: Pearson correlation coefficient between method prediction and ground truth for COVID-19 cases was calculated as 0.92 for PO (P < .001), 0.97 for PHO(P < .001), 0.91 for LSS (P < .001), 0.90 for LHOS (P < .001). 98 of 100 healthy controls had a predicted PO of less than 1%, 2 had between 1-2%. Automated processing time to compute the severity scores was 10 seconds per case compared to 30 minutes required for manual annotations. Conclusion: A new method segments regions of CT abnormalities associated with COVID-19 and computes (PO, PHO), as well as (LSS, LHOS) severity scores.