1.2APDec 15, 2015
When interpolation-induced reflection artifact meets time-frequency analysisYu-Ting Lin, Patrick Flandrin, Hau-tieng Wu
While extracting the temporal dynamical features based on the time-frequency analyses, like the reassignment and synchrosqueezing transform, attracts more and more interest in bio-medical data analysis, we should be careful about artifacts generated by interpolation schemes, in particular when the sampling rate is not significantly higher than the frequency of the oscillatory component we are interested in. In this study, we formulate the problem called the reflection effect and provide a theoretical justification of the statement. We also show examples in the anesthetic depth analysis with clear but undesirable artifacts. The results show that the artifact associated with the reflection effect exists not only theoretically but practically. Its influence is pronounced when we apply the time-frequency analyses to extract the time-varying dynamics hidden inside the signal. In conclusion, we have to carefully deal with the artifact associated with the reflection effect by choosing a proper interpolation scheme.
1.2QMSep 21, 2021
Arterial blood pressure waveform in liver transplant surgery possesses variability of morphology reflecting recipients' acuity and predicting short term outcomesShen-Chih Wang, Chien-Kun Ting, Cheng-Yen Chen et al.
Background: We investigated clinical information underneath the beat-to-beat fluctuation of the arterial blood pressure (ABP) waveform morphology. We proposed the Dynamical Diffusion Map algorithm (DDMap) to quantify the variability of morphology. The underlying physiology could be the compensatory mechanisms involving complex interactions between various physiological mechanisms to regulate the cardiovascular system. As a liver transplant surgery contains distinct periods, we investigated its clinical behavior in different surgical steps. Methods: Our study used DDmap algorithm, based on unsupervised manifold learning, to obtain a quantitative index for the beat-to-beat variability of morphology. We examined the correlation between the variability of ABP morphology and disease acuity as indicated by Model for End-Stage Liver Disease (MELD) scores, the postoperative laboratory data, and 4 early allograft failure (EAF) scores. Results: Among the 85 enrolled patients, the variability of morphology obtained during the presurgical phase was best correlated with MELD-Na scores. The neohepatic phase variability of morphology was associated with EAF scores as well as postoperative bilirubin levels, international normalized ratio, aspartate aminotransferase levels, and platelet count. Furthermore, variability of morphology presents more associations with the above clinical conditions than the common BP measures and their BP variability indices. Conclusions: The variability of morphology obtained during the presurgical phase is indicative of patient acuity, whereas those during the neohepatic phase are indicative of short-term surgical outcomes.
1.2QMAug 27, 2018
Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor dataYu-Ting Lin, Yu-Lun Lo, Chen-Yun Lin et al.
Object: It is increasingly popular to collect as much data as possible in the hospital setting from clinical monitors for research purposes. However, in this setup the data calibration issue is often not discussed and, rather, implicitly assumed, while the clinical monitors might not be designed for the data analysis purpose. We hypothesize that this calibration issue for a secondary analysis may become an important source of artifacts in patient monitor data. We test an off-the-shelf integrated photoplethysmography (PPG) and electrocardiogram (ECG) monitoring device for its ability to yield a reliable pulse transit time (PTT) signal. Approach: This is a retrospective clinical study using two databases: one containing 35 subjects who underwent laparoscopic cholecystectomy, another containing 22 subjects who underwent spontaneous breathing test in the intensive care unit. All data sets include recordings of PPG and ECG using a commonly deployed patient monitor. We calculated the PTT signal offline. Main Results: We report a novel constant oscillatory pattern in the PTT signal and identify this pattern as a sawtooth artifact. We apply an approach based on the de-shape method to visualize, quantify and validate this sawtooth artifact. Significance: The PPG and ECG signals not designed for the PTT evaluation may contain unwanted artifacts. The PTT signal should be calibrated before analysis to avoid erroneous interpretation of its physiological meaning.