8.6APMay 30, 2018
Reference-free Calibration in Sensor NetworksRaj Thilak Rajan, Rob-van Schaijk, Anup Das et al.
Sensor calibration is one of the fundamental challenges in large-scale IoT networks. In this article, we address the challenge of reference-free calibration of a densely deployed sensor network. Conventionally, to calibrate an in-place sensor network (or sensor array), a reference is arbitrarily chosen with or without prior information on sensor performance. However, an arbitrary selection of a reference could prove fatal, if an erroneous sensor is inadvertently chosen. To avert single point of dependence, and to improve estimator performance, we propose unbiased reference-free algorithms. Although, our focus is on reference-free solutions, the proposed framework, allows the incorporation of additional references, if available. We show with the help of simulations that the proposed solutions achieve the derived statistical lower bounds asymptotically. In addition, the proposed algorithms show improvements on real-life datasets, as compared to prevalent algorithms.
19.4NEJul 18, 2017
Unsupervised Heart-rate Estimation in Wearables With Liquid States and A Probabilistic ReadoutAnup Das, Paruthi Pradhapan, Willemijn Groenendaal et al.
Heart-rate estimation is a fundamental feature of modern wearable devices. In this paper we propose a machine intelligent approach for heart-rate estimation from electrocardiogram (ECG) data collected using wearable devices. The novelty of our approach lies in (1) encoding spatio-temporal properties of ECG signals directly into spike train and using this to excite recurrently connected spiking neurons in a Liquid State Machine computation model; (2) a novel learning algorithm; and (3) an intelligently designed unsupervised readout based on Fuzzy c-Means clustering of spike responses from a subset of neurons (Liquid states), selected using particle swarm optimization. Our approach differs from existing works by learning directly from ECG signals (allowing personalization), without requiring costly data annotations. Additionally, our approach can be easily implemented on state-of-the-art spiking-based neuromorphic systems, offering high accuracy, yet significantly low energy footprint, leading to an extended battery life of wearable devices. We validated our approach with CARLsim, a GPU accelerated spiking neural network simulator modeling Izhikevich spiking neurons with Spike Timing Dependent Plasticity (STDP) and homeostatic scaling. A range of subjects are considered from in-house clinical trials and public ECG databases. Results show high accuracy and low energy footprint in heart-rate estimation across subjects with and without cardiac irregularities, signifying the strong potential of this approach to be integrated in future wearable devices.