Xingyu Hu

CV
h-index7
3papers
14citations
Novelty53%
AI Score36

3 Papers

6.2CVApr 7, 2025Code
Balancing Task-invariant Interaction and Task-specific Adaptation for Unified Image Fusion

Xingyu Hu, Junjun Jiang, Chenyang Wang et al.

Unified image fusion aims to integrate complementary information from multi-source images, enhancing image quality through a unified framework applicable to diverse fusion tasks. While treating all fusion tasks as a unified problem facilitates task-invariant knowledge sharing, it often overlooks task-specific characteristics, thereby limiting the overall performance. Existing general image fusion methods incorporate explicit task identification to enable adaptation to different fusion tasks. However, this dependence during inference restricts the model's generalization to unseen fusion tasks. To address these issues, we propose a novel unified image fusion framework named "TITA", which dynamically balances both Task-invariant Interaction and Task-specific Adaptation. For task-invariant interaction, we introduce the Interaction-enhanced Pixel Attention (IPA) module to enhance pixel-wise interactions for better multi-source complementary information extraction. For task-specific adaptation, the Operation-based Adaptive Fusion (OAF) module dynamically adjusts operation weights based on task properties. Additionally, we incorporate the Fast Adaptive Multitask Optimization (FAMO) strategy to mitigate the impact of gradient conflicts across tasks during joint training. Extensive experiments demonstrate that TITA not only achieves competitive performance compared to specialized methods across three image fusion scenarios but also exhibits strong generalization to unseen fusion tasks. The source codes are released at https://github.com/huxingyuabc/TITA.

6.5CVJan 12, 2024
Enhancing Consistency and Mitigating Bias: A Data Replay Approach for Incremental Learning

Chenyang Wang, Junjun Jiang, Xingyu Hu et al.

Deep learning systems are prone to catastrophic forgetting when learning from a sequence of tasks, as old data from previous tasks is unavailable when learning a new task. To address this, some methods propose replaying data from previous tasks during new task learning, typically using extra memory to store replay data. However, it is not expected in practice due to memory constraints and data privacy issues. Instead, data-free replay methods invert samples from the classification model. While effective, these methods face inconsistencies between inverted and real training data, overlooked in recent works. To that effect, we propose to measure the data consistency quantitatively by some simplification and assumptions. Using this measurement, we gain insight to develop a novel loss function that reduces inconsistency. Specifically, the loss minimizes the KL divergence between distributions of inverted and real data under a tied multivariate Gaussian assumption, which is simple to implement in continual learning. Additionally, we observe that old class weight norms decrease continually as learning progresses. We analyze the reasons and propose a regularization term to balance class weights, making old class samples more distinguishable. To conclude, we introduce Consistency-enhanced data replay with a Debiased classifier for class incremental learning (CwD). Extensive experiments on CIFAR-100, Tiny-ImageNet, and ImageNet100 show consistently improved performance of CwD compared to previous approaches.

5.8AIAug 3, 2025
SURE-Med: Systematic Uncertainty Reduction for Enhanced Reliability in Medical Report Generation

Yuhang Gu, Xingyu Hu, Yuyu Fan et al.

Automated medical report generation (MRG) holds great promise for reducing the heavy workload of radiologists. However, its clinical deployment is hindered by three major sources of uncertainty. First, visual uncertainty, caused by noisy or incorrect view annotations, compromises feature extraction. Second, label distribution uncertainty, stemming from long-tailed disease prevalence, biases models against rare but clinically critical conditions. Third, contextual uncertainty, introduced by unverified historical reports, often leads to factual hallucinations. These challenges collectively limit the reliability and clinical trustworthiness of MRG systems. To address these issues, we propose SURE-Med, a unified framework that systematically reduces uncertainty across three critical dimensions: visual, distributional, and contextual. To mitigate visual uncertainty, a Frontal-Aware View Repair Resampling module corrects view annotation errors and adaptively selects informative features from supplementary views. To tackle label distribution uncertainty, we introduce a Token Sensitive Learning objective that enhances the modeling of critical diagnostic sentences while reweighting underrepresented diagnostic terms, thereby improving sensitivity to infrequent conditions. To reduce contextual uncertainty, our Contextual Evidence Filter validates and selectively incorporates prior information that aligns with the current image, effectively suppressing hallucinations. Extensive experiments on the MIMIC-CXR and IU-Xray benchmarks demonstrate that SURE-Med achieves state-of-the-art performance. By holistically reducing uncertainty across multiple input modalities, SURE-Med sets a new benchmark for reliability in medical report generation and offers a robust step toward trustworthy clinical decision support.