CVJun 29, 2025Code
Frequency-enhanced Multi-granularity Context Network for Efficient Vertebrae SegmentationJian Shi, Tianqi You, Pingping Zhang et al.
Automated and accurate segmentation of individual vertebra in 3D CT and MRI images is essential for various clinical applications. Due to the limitations of current imaging techniques and the complexity of spinal structures, existing methods still struggle with reducing the impact of image blurring and distinguishing similar vertebrae. To alleviate these issues, we introduce a Frequency-enhanced Multi-granularity Context Network (FMC-Net) to improve the accuracy of vertebrae segmentation. Specifically, we first apply wavelet transform for lossless downsampling to reduce the feature distortion in blurred images. The decomposed high and low-frequency components are then processed separately. For the high-frequency components, we apply a High-frequency Feature Refinement (HFR) to amplify the prominence of key features and filter out noises, restoring fine-grained details in blurred images. For the low-frequency components, we use a Multi-granularity State Space Model (MG-SSM) to aggregate feature representations with different receptive fields, extracting spatially-varying contexts while capturing long-range dependencies with linear complexity. The utilization of multi-granularity contexts is essential for distinguishing similar vertebrae and improving segmentation accuracy. Extensive experiments demonstrate that our method outperforms state-of-the-art approaches on both CT and MRI vertebrae segmentation datasets. The source code is publicly available at https://github.com/anaanaa/FMCNet.
96.4LGApr 10
ECHO: Efficient Chest X-ray Report Generation with One-step Block DiffusionLifeng Chen, Tianqi You, Hao Liu et al.
Chest X-ray report generation (CXR-RG) has the potential to substantially alleviate radiologists' workload. However, conventional autoregressive vision--language models (VLMs) suffer from high inference latency due to sequential token decoding. Diffusion-based models offer a promising alternative through parallel generation, but they still require multiple denoising iterations. Compressing multi-step denoising to a single step could further reduce latency, but often degrades textual coherence due to the mean-field bias introduced by token-factorized denoisers. To address this challenge, we propose \textbf{ECHO}, an efficient diffusion-based VLM (dVLM) for chest X-ray report generation. ECHO enables stable one-step-per-block inference via a novel Direct Conditional Distillation (DCD) framework, which mitigates the mean-field limitation by constructing unfactorized supervision from on-policy diffusion trajectories to encode joint token dependencies. In addition, we introduce a Response-Asymmetric Diffusion (RAD) training strategy that further improves training efficiency while maintaining model effectiveness. Extensive experiments demonstrate that ECHO surpasses state-of-the-art autoregressive methods, improving RaTE and SemScore by \textbf{64.33\%} and \textbf{60.58\%} respectively, while achieving an \textbf{$8\times$} inference speedup without compromising clinical accuracy.