Siqiao Li

IV
h-index16
3papers
7citations
Novelty48%
AI Score48

3 Papers

IVJun 22, 2025Code
LVPNet: A Latent-variable-based Prediction-driven End-to-end Framework for Lossless Compression of Medical Images

Chenyue Song, Chen Hui, Qing Lin et al.

Autoregressive Initial Bits is a framework that integrates sub-image autoregression and latent variable modeling, demonstrating its advantages in lossless medical image compression. However, in existing methods, the image segmentation process leads to an even distribution of latent variable information across each sub-image, which in turn causes posterior collapse and inefficient utilization of latent variables. To deal with these issues, we propose a prediction-based end-to-end lossless medical image compression method named LVPNet, leveraging global latent variables to predict pixel values and encoding predicted probabilities for lossless compression. Specifically, we introduce the Global Multi-scale Sensing Module (GMSM), which extracts compact and informative latent representations from the entire image, effectively capturing spatial dependencies within the latent space. Furthermore, to mitigate the information loss introduced during quantization, we propose the Quantization Compensation Module (QCM), which learns the distribution of quantization errors and refines the quantized features to compensate for quantization loss. Extensive experiments on challenging benchmarks demonstrate that our method achieves superior compression efficiency compared to state-of-the-art lossless image compression approaches, while maintaining competitive inference speed. The code is at https://github.com/scy-Jackel/LVPNet.

IVJun 25, 2025Code
MS-IQA: A Multi-Scale Feature Fusion Network for PET/CT Image Quality Assessment

Siqiao Li, Chen Hui, Wei Zhang et al.

Positron Emission Tomography / Computed Tomography (PET/CT) plays a critical role in medical imaging, combining functional and anatomical information to aid in accurate diagnosis. However, image quality degradation due to noise, compression and other factors could potentially lead to diagnostic uncertainty and increase the risk of misdiagnosis. When evaluating the quality of a PET/CT image, both low-level features like distortions and high-level features like organ anatomical structures affect the diagnostic value of the image. However, existing medical image quality assessment (IQA) methods are unable to account for both feature types simultaneously. In this work, we propose MS-IQA, a novel multi-scale feature fusion network for PET/CT IQA, which utilizes multi-scale features from various intermediate layers of ResNet and Swin Transformer, enhancing its ability of perceiving both local and global information. In addition, a multi-scale feature fusion module is also introduced to effectively combine high-level and low-level information through a dynamically weighted channel attention mechanism. Finally, to fill the blank of PET/CT IQA dataset, we construct PET-CT-IQA-DS, a dataset containing 2,700 varying-quality PET/CT images with quality scores assigned by radiologists. Experiments on our dataset and the publicly available LDCTIQAC2023 dataset demonstrate that our proposed model has achieved superior performance against existing state-of-the-art methods in various IQA metrics. This work provides an accurate and efficient IQA method for PET/CT. Our code and dataset are available at https://github.com/MS-IQA/MS-IQA/.

IVMay 1
Unsupervised Denoising of Real Clinical Low Dose Liver CT with Perceptual Attention Networks

Jingxi Pu, Tonghua Liu, Zhilin Guan et al.

With the development of deep learning, medical image processing has been widely used to assist clinical research. This paper focuses on the denoising problem of low-dose computed tomography using deep learning. Although low-dose computed tomography reduces radiation exposure to patients, it also introduces more noise, which may interfere with visual interpretation by physicians and affect diagnostic results. To address this problem, inspired by Cycle-GAN for unsupervised learning, this paper proposes an end-to-end unsupervised low-dose computed tomography denoising framework. The proposed framework combines a U-Net structure for multi-scale feature extraction, an attention mechanism for feature fusion, and a residual network for feature transformation. It also introduces perceptual loss to improve the network for the characteristics of medical images. In addition, we construct a real low-dose computed tomography dataset and design a large number of comparative experiments to validate the proposed method, using both image-based evaluation metrics and medical evaluation criteria. Compared with classical methods, the main advantage of this paper is that it addresses the limitation that real clinical data cannot be directly used for supervised learning, while still achieving excellent performance. The experimental results are also professionally evaluated by imaging physicians and meet clinical needs.