3.0IVMar 13, 2023
Optimizing Convolutional Neural Networks for Chronic Obstructive Pulmonary Disease Detection in Clinical Computed Tomography ImagingTina Dorosti, Manuel Schultheiss, Felix Hofmann et al.
We aim to optimize the binary detection of Chronic Obstructive Pulmonary Disease (COPD) based on emphysema presence in the lung with convolutional neural networks (CNN) by exploring manually adjusted versus automated window-setting optimization (WSO) on computed tomography (CT) images. 7,194 CT images (3,597 with COPD; 3,597 healthy controls) from 78 subjects were selected retrospectively (10.2018-12.2021) and preprocessed. For each image, intensity values were manually clipped to the emphysema window setting and a baseline 'full-range' window setting. Class-balanced train, validation, and test sets contained 3,392, 1,114, and 2,688 images. The network backbone was optimized by comparing various CNN architectures. Furthermore, automated WSO was implemented by adding a customized layer to the model. The image-level area under the Receiver Operating Characteristics curve (AUC) [lower, upper limit 95% confidence] was utilized to compare model variations. Repeated inference (n=7) on the test set showed that the DenseNet was the most efficient backbone and achieved a mean AUC of 0.80 [0.76, 0.85] without WSO. Comparably, with input images manually adjusted to the emphysema window, the DenseNet model predicted COPD with a mean AUC of 0.86 [0.82, 0.89]. By adding a customized WSO layer to the DenseNet, an optimal window in the proximity of the emphysema window setting was learned automatically, and a mean AUC of 0.82 [0.78, 0.86] was achieved. Detection of COPD with DenseNet models was improved by WSO of CT data to the emphysema window setting range.
Neighbor2Inverse: Self-Supervised Denoising for Low-Dose Region-of-Interest Phase Contrast CTJohannes B. Thalhammer, Lorenzo D'Amico, Lucy Costello et al.
Propagation-based X-ray phase-contrast imaging (PBI) enables high-contrast visualization of lung structures and holds strong medical potential. However, safe translation to the clinic will require a substantial radiation dose reduction, which inevitably increases image noise. Supervised convolutional-neural-network-based denoising can restore image quality but depends on paired low- and high-dose datasets, which are rarely available in practice. Self-supervised methods avoid this limitation, yet most are not well adapted to the inverse problem of PBI computed tomography (CT). We introduce Neighbor2Inverse, a self-supervised denoising framework designed for low-dose PBI-CT that generalizes to clinical CT. Building on the Neighbor2Neighbor principle, each noisy projection is subsampled into two variants that preserve structural information but contain independent noise realizations. These are reconstructed separately, and the resulting pairs are used to train a denoising network directly in the image domain. We benchmark the proposed method against established analytical and self-supervised denoising approaches. In region-of-interest PBI CT experiments, Neighbor2Inverse achieves superior noise suppression while preserving fine structural details, as demonstrated by improved contrast-to-noise ratio, spatial resolution, and composite image quality metrics. Competitive performance is also observed on clinical CT data under simulated low-dose conditions. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible. Code, data, and interactive figures are available at https://github.com/J-3TO/Neighbor2Inverse.
Artifact Reduction in Undersampled 3D Cone-Beam CTs using a Hybrid 2D-3D CNN FrameworkJohannes Thalhammer, Tina Dorosti, Sebastian Peterhansl et al.
Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utility. Reducing these artifacts is critical for high-quality imaging. We propose a computationally efficient hybrid deep-learning framework that combines the strengths of 2D and 3D models. First, a 2D U-Net operates on individual slices of undersampled CT volumes to extract feature maps. These slice-wise feature maps are then stacked across the volume and used as input to a 3D decoder, which utilizes contextual information across slices to predict an artifact-free 3D CT volume. The proposed two-stage approach balances the computational efficiency of 2D processing with the volumetric consistency provided by 3D modeling. The results show substantial improvements in inter-slice consistency in coronal and sagittal direction with low computational overhead. This hybrid framework presents a robust and efficient solution for high-quality 3D CT image post-processing. The code of this project can be found on github: https://github.com/J-3TO/2D-3DCNN_sparseview/.
Improving image quality of sparse-view lung tumor CT images with U-NetAnnika Ries, Tina Dorosti, Johannes Thalhammer et al.
Background: We aimed at improving image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determining the best tradeoff between number of views, IQ, and diagnostic confidence. Methods: CT images from 41 subjects aged 62.8 $\pm$ 10.6 years (mean $\pm$ standard deviation), 23 men, 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used. Results: The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images. Conclusions: Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level.
7.3IVMar 16, 2023
Improving Automated Hemorrhage Detection in Sparse-view Computed Tomography via Deep Convolutional Neural Network based Artifact ReductionJohannes Thalhammer, Manuel Schultheiss, Tina Dorosti et al.
This is a preprint. The latest version has been published here: https://pubs.rsna.org/doi/10.1148/ryai.230275 Purpose: Sparse-view computed tomography (CT) is an effective way to reduce dose by lowering the total number of views acquired, albeit at the expense of image quality, which, in turn, can impact the ability to detect diseases. We explore deep learning-based artifact reduction in sparse-view cranial CT scans and its impact on automated hemorrhage detection. Methods: We trained a U-Net for artefact reduction on simulated sparse-view cranial CT scans from 3000 patients obtained from a public dataset and reconstructed with varying levels of sub-sampling. Additionally, we trained a convolutional neural network on fully sampled CT data from 17,545 patients for automated hemorrhage detection. We evaluated the classification performance using the area under the receiver operator characteristic curves (AUC-ROCs) with corresponding 95% confidence intervals (CIs) and the DeLong test, along with confusion matrices. The performance of the U-Net was compared to an analytical approach based on total variation (TV). Results: The U-Net performed superior compared to unprocessed and TV-processed images with respect to image quality and automated hemorrhage diagnosis. With U-Net post-processing, the number of views can be reduced from 4096 (AUC-ROC: 0.974; 95% CI: 0.972-0.976) views to 512 views (0.973; 0.971-0.975) with minimal decrease in hemorrhage detection (P<.001) and to 256 views (0.967; 0.964-0.969) with a slight performance decrease (P<.001). Conclusion: The results suggest that U-Net based artifact reduction substantially enhances automated hemorrhage detection in sparse-view cranial CTs. Our findings highlight that appropriate post-processing is crucial for optimal image quality and diagnostic accuracy while minimizing radiation dose.
1.4LGJan 22
Uncertainty-guided Generation of Dark-field RadiographsLina Felsner, Henriette Bast, Tina Dorosti et al.
X-ray dark-field radiography provides complementary diagnostic information to conventional attenuation imaging by visualizing microstructural tissue changes through small-angle scattering. However, the limited availability of such data poses challenges for developing robust deep learning models. In this work, we present the first framework for generating dark-field images directly from standard attenuation chest X-rays using an Uncertainty-Guided Progressive Generative Adversarial Network. The model incorporates both aleatoric and epistemic uncertainty to improve interpretability and reliability. Experiments demonstrate high structural fidelity of the generated images, with consistent improvement of quantitative metrics across stages. Furthermore, out-of-distribution evaluation confirms that the proposed model generalizes well. Our results indicate that uncertainty-guided generative modeling enables realistic dark-field image synthesis and provides a reliable foundation for future clinical applications.