Nicolas Toussaint

CV
h-index16
5papers
92citations
Novelty42%
AI Score35

5 Papers

6.2CVSep 23, 2025Code
Zero-shot Monocular Metric Depth for Endoscopic Images

Nicolas Toussaint, Emanuele Colleoni, Ricardo Sanchez-Matilla et al.

Monocular relative and metric depth estimation has seen a tremendous boost in the last few years due to the sharp advancements in foundation models and in particular transformer based networks. As we start to see applications to the domain of endoscopic images, there is still a lack of robust benchmarks and high-quality datasets in that area. This paper addresses these limitations by presenting a comprehensive benchmark of state-of-the-art (metric and relative) depth estimation models evaluated on real, unseen endoscopic images, providing critical insights into their generalisation and performance in clinical scenarios. Additionally, we introduce and publish a novel synthetic dataset (EndoSynth) of endoscopic surgical instruments paired with ground truth metric depth and segmentation masks, designed to bridge the gap between synthetic and real-world data. We demonstrate that fine-tuning depth foundation models using our synthetic dataset boosts accuracy on most unseen real data by a significant margin. By providing both a benchmark and a synthetic dataset, this work advances the field of depth estimation for endoscopic images and serves as an important resource for future research. Project page, EndoSynth dataset and trained weights are available at https://github.com/TouchSurgery/EndoSynth.

2.3CVJul 13, 2020
Screen Tracking for Clinical Translation of Live Ultrasound Image Analysis Methods

Simona Treivase, Alberto Gomez, Jacqueline Matthew et al.

Ultrasound (US) imaging is one of the most commonly used non-invasive imaging techniques. However, US image acquisition requires simultaneous guidance of the transducer and interpretation of images, which is a highly challenging task that requires years of training. Despite many recent developments in intra-examination US image analysis, the results are not easy to translate to a clinical setting. We propose a generic framework to extract the US images and superimpose the results of an analysis task, without any need for physical connection or alteration to the US system. The proposed method captures the US image by tracking the screen with a camera fixed at the sonographer's view point and reformats the captured image to the right aspect ratio, in 87.66 +- 3.73ms on average. It is hypothesized that this would enable to input such retrieved image into an image processing pipeline to extract information that can help improve the examination. This information could eventually be projected back to the sonographer's field of view in real time using, for example, an augmented reality (AR) headset.

15.6IVAug 7, 2019
Confident Head Circumference Measurement from Ultrasound with Real-time Feedback for Sonographers

Samuel Budd, Matthew Sinclair, Bishesh Khanal et al.

Manual estimation of fetal Head Circumference (HC) from Ultrasound (US) is a key biometric for monitoring the healthy development of fetuses. Unfortunately, such measurements are subject to large inter-observer variability, resulting in low early-detection rates of fetal abnormalities. To address this issue, we propose a novel probabilistic Deep Learning approach for real-time automated estimation of fetal HC. This system feeds back statistics on measurement robustness to inform users how confident a deep neural network is in evaluating suitable views acquired during free-hand ultrasound examination. In real-time scenarios, this approach may be exploited to guide operators to scan planes that are as close as possible to the underlying distribution of training images, for the purpose of improving inter-operator consistency. We train on free-hand ultrasound data from over 2000 subjects (2848 training/540 test) and show that our method is able to predict HC measurements within 1.81$\pm$1.65mm deviation from the ground truth, with 50% of the test images fully contained within the predicted confidence margins, and an average of 1.82$\pm$1.78mm deviation from the margin for the remaining cases that are not fully contained.

8.3ROFeb 14, 2019
Robotic-assisted Ultrasound for Fetal Imaging: Evolution from Single-arm to Dual-arm System

Shuangyi Wang, James Housden, Yohan Noh et al.

The development of robotic-assisted extracorporeal ultrasound systems has a long history and a number of projects have been proposed since the 1990s focusing on different technical aspects. These aim to resolve the deficiencies of on-site manual manipulation of hand-held ultrasound probes. This paper presents the recent ongoing developments of a series of bespoke robotic systems, including both single-arm and dual-arm versions, for a project known as intelligent Fetal Imaging and Diagnosis (iFIND). After a brief review of the development history of the extracorporeal ultrasound robotic system used for fetal and abdominal examinations, the specific aim of the iFIND robots, the design evolution, the implementation details of each version, and the initial clinical feedback of the iFIND robot series are presented. Based on the preliminary testing of these newly-proposed robots on 42 volunteers, the successful and re-liable working of the mechatronic systems were validated. Analysis of a participant questionnaire indicates a comfortable scanning experience for the volunteers and a good acceptance rate to being scanned by the robots.

6.3CVAug 2, 2018
Weakly Supervised Localisation for Fetal Ultrasound Images

Nicolas Toussaint, Bishesh Khanal, Matthew Sinclair et al.

This paper addresses the task of detecting and localising fetal anatomical regions in 2D ultrasound images, where only image-level labels are present at training, i.e. without any localisation or segmentation information. We examine the use of convolutional neural network architectures coupled with soft proposal layers. The resulting network simultaneously performs anatomical region detection (classification) and localisation tasks. We generate a proposal map describing the attention of the network for a particular class. The network is trained on 85,500 2D fetal Ultrasound images and their associated labels. Labels correspond to six anatomical regions: head, spine, thorax, abdomen, limbs, and placenta. Detection achieves an average accuracy of 90\% on individual regions, and show that the proposal maps correlate well with relevant anatomical structures. This work presents itself as a powerful and essential step towards subsequent tasks such as fetal position and pose estimation, organ-specific segmentation, or image-guided navigation. Code and additional material is available at https://ntoussaint.github.io/fetalnav