Ph. D.

CL
h-index12
9papers
279citations
Novelty23%
AI Score38

9 Papers

SYApr 14, 2023
Car-Following Models: A Multidisciplinary Review

Tianya Zhang, Ph. D., Peter J. Jin et al.

Car-following (CF) algorithms are crucial components of traffic simulations and have been integrated into many production vehicles equipped with Advanced Driving Assistance Systems (ADAS). Insights from the model of car-following behavior help us understand the causes of various macro phenomena that arise from interactions between pairs of vehicles. Car-following models encompass multiple disciplines, including traffic engineering, physics, dynamic system control, cognitive science, machine learning, and reinforcement learning. This paper presents an extensive survey that highlights the differences, complementarities, and overlaps among microscopic traffic flow and control models based on their underlying principles and design logic. It reviews representative algorithms, ranging from theory-based kinematic models, Psycho-Physical Models, and Adaptive cruise control models to data-driven algorithms like Reinforcement Learning (RL) and Imitation Learning (IL). The manuscript discusses the strengths and limitations of these models and explores their applications in different contexts. This review synthesizes existing researches across different domains to fill knowledge gaps and offer guidance for future research by identifying the latest trends in car following models and their applications.

75.4CLMar 24
PLACID: Privacy-preserving Large language models for Acronym Clinical Inference and Disambiguation

Manjushree B. Aithal, Ph. D., Alexander Kotz et al.

Large Language Models (LLMs) offer transformative solutions across many domains, but healthcare integration is hindered by strict data privacy constraints. Clinical narratives are dense with ambiguous acronyms, misinterpretation these abbreviations can precipitate severe outcomes like life-threatening medication errors. While cloud-dependent LLMs excel at Acronym Disambiguation, transmitting Protected Health Information to external servers violates privacy frameworks. To bridge this gap, this study pioneers the evaluation of small-parameter models deployed entirely on-device to ensure privacy preservation. We introduce a privacy-preserving cascaded pipeline leveraging general-purpose local models to detect clinical acronyms, routing them to domain-specific biomedical models for context-relevant expansions. Results reveal that while general instruction-following models achieve high detection accuracy (~0.988), their expansion capabilities plummet (~0.655). Our cascaded approach utilizes domain-specific medical models to increase expansion accuracy to (~0.81). This novel work demonstrates that privacy-preserving, on-device (2B-10B) models deliver high-fidelity clinical acronym disambiguation support.

SEOct 23, 2019Code
Development and evaluation of an open-source, machine learning-based average annual daily traffic estimation software

Zadid Khan, Sakib Mahmud Khan, Ph. D. et al.

Traditionally, Departments of Transportation (DOTs) use the factor-based model to estimate Annual Average Daily Traffic (AADT) from short-term traffic counts. The expansion factors, derived from the permanent traffic count stations, are applied to the short-term counts for AADT estimation. The inherent challenges of the factor-based method (i.e., grouping the count stations, applying proper expansion factors) make the estimated AADT values erroneous. Based on a survey conducted by the authors, 97% of the 39 public transportation agencies use the factor-based AADT estimation model, and these agencies face the aforementioned challenges while using factor-based models to estimate AADT. To derive a more accurate AADT, this paper presents the "estimAADTion" software, which is an open-source software developed based on a machine learning method called support vector regression (SVR) for estimating AADT using 24-hour short-term count data. DOTs conduct short-term counts at different locations periodically. This software has been designed to estimate AADT at a particular location from the short-term counts collected at those locations. In order to estimate AADT from short-term counts, the software uses data from permanent count stations to train the SVR model. The performance of the "estimAADTion" software is validated using the short-term count data from South Carolina. The Mean Absolute Percentage Error (MAPE) of the AADT estimated from the software is 3%, while the factor-based method produces a MAPE value of 6%.

AIJun 13, 2025
Large Language Model-Powered Conversational Agent Delivering Problem-Solving Therapy (PST) for Family Caregivers: Enhancing Empathy and Therapeutic Alliance Using In-Context Learning

Liying Wang, Ph. D., Daffodil Carrington et al. · uw

Family caregivers often face substantial mental health challenges due to their multifaceted roles and limited resources. This study explored the potential of a large language model (LLM)-powered conversational agent to deliver evidence-based mental health support for caregivers, specifically Problem-Solving Therapy (PST) integrated with Motivational Interviewing (MI) and Behavioral Chain Analysis (BCA). A within-subject experiment was conducted with 28 caregivers interacting with four LLM configurations to evaluate empathy and therapeutic alliance. The best-performing models incorporated Few-Shot and Retrieval-Augmented Generation (RAG) prompting techniques, alongside clinician-curated examples. The models showed improved contextual understanding and personalized support, as reflected by qualitative responses and quantitative ratings on perceived empathy and therapeutic alliances. Participants valued the model's ability to validate emotions, explore unexpressed feelings, and provide actionable strategies. However, balancing thorough assessment with efficient advice delivery remains a challenge. This work highlights the potential of LLMs in delivering empathetic and tailored support for family caregivers.

CVNov 22, 2020
Deep learning model trained on mobile phone-acquired frozen section images effectively detects basal cell carcinoma

Junli Cao, B. S., Junyan Wu et al.

Background: Margin assessment of basal cell carcinoma using the frozen section is a common task of pathology intraoperative consultation. Although frequently straight-forward, the determination of the presence or absence of basal cell carcinoma on the tissue sections can sometimes be challenging. We explore if a deep learning model trained on mobile phone-acquired frozen section images can have adequate performance for future deployment. Materials and Methods: One thousand two hundred and forty-one (1241) images of frozen sections performed for basal cell carcinoma margin status were acquired using mobile phones. The photos were taken at 100x magnification (10x objective). The images were downscaled from a 4032 x 3024 pixel resolution to 576 x 432 pixel resolution. Semantic segmentation algorithm Deeplab V3 with Xception backbone was used for model training. Results: The model uses an image as input and produces a 2-dimensional black and white output of prediction of the same dimension; the areas determined to be basal cell carcinoma were displayed with white color, in a black background. Any output with the number of white pixels exceeding 0.5% of the total number of pixels is deemed positive for basal cell carcinoma. On the test set, the model achieves area under curve of 0.99 for receiver operator curve and 0.97 for precision-recall curve at the pixel level. The accuracy of classification at the slide level is 96%. Conclusions: The deep learning model trained with mobile phone images shows satisfactory performance characteristics, and thus demonstrates the potential for deploying as a mobile phone app to assist in frozen section interpretation in real time.

CLFeb 2, 2020
Assessment of Amazon Comprehend Medical: Medication Information Extraction

Benedict Guzman, MS, Isabel Metzger et al.

In November 27, 2018, Amazon Web Services (AWS) released Amazon Comprehend Medical (ACM), a deep learning based system that automatically extracts clinical concepts (which include anatomy, medical conditions, protected health information (PH)I, test names, treatment names, and medical procedures, and medications) from clinical text notes. Uptake and trust in any new data product relies on independent validation across benchmark datasets and tools to establish and confirm expected quality of results. This work focuses on the medication extraction task, and particularly, ACM was evaluated using the official test sets from the 2009 i2b2 Medication Extraction Challenge and 2018 n2c2 Track 2: Adverse Drug Events and Medication Extraction in EHRs. Overall, ACM achieved F-scores of 0.768 and 0.828. These scores ranked the lowest when compared to the three best systems in the respective challenges. To further establish the generalizability of its medication extraction performance, a set of random internal clinical text notes from NYU Langone Medical Center were also included in this work. And in this corpus, ACM garnered an F-score of 0.753.

IVOct 18, 2019
Intracranial Hemorrhage Segmentation Using Deep Convolutional Model

Murtadha D. Hssayeni, M. S., Muayad S. Croock et al.

Traumatic brain injuries could cause intracranial hemorrhage (ICH). ICH could lead to disability or death if it is not accurately diagnosed and treated in a time-sensitive procedure. The current clinical protocol to diagnose ICH is examining Computerized Tomography (CT) scans by radiologists to detect ICH and localize its regions. However, this process relies heavily on the availability of an experienced radiologist. In this paper, we designed a study protocol to collect a dataset of 82 CT scans of subjects with traumatic brain injury. Later, the ICH regions were manually delineated in each slice by a consensus decision of two radiologists. Recently, fully convolutional networks (FCN) have shown to be successful in medical image segmentation. We developed a deep FCN, called U-Net, to segment the ICH regions from the CT scans in a fully automated manner. The method achieved a Dice coefficient of 0.31 for the ICH segmentation based on 5-fold cross-validation. The dataset is publicly available online at PhysioNet repository for future analysis and comparison.

CYNov 28, 2018
A comparison of cluster algorithms as applied to unsupervised surveys

Kathleen Campbell Garwood, Ph. D., Arpit Arun Dhobale

When considering answering important questions with data, unsupervised data offers extensive insight opportunity and unique challenges. This study considers student survey data with a specific goal of clustering students into like groups with underlying concept of identifying different poverty levels. Fuzzy logic is considered during the data cleaning and organizing phase helping to create a logical dependent variable for analysis comparison. Using multiple data reduction techniques, the survey was reduced and cleaned. Finally, multiple clustering techniques (k-means, k-modes, and hierarchical clustering) are applied and compared. Though each method has strengths, the goal was to identify which was most viable when applied to survey data and specifically when trying to identify the most impoverished students.

NEAug 3, 2018
Geared Rotationally Identical and Invariant Convolutional Neural Network Systems

ShihChung B. Lo, Ph. D., Matthew T. Freedman et al.

Theorems and techniques to form different types of transformationally invariant processing and to produce the same output quantitatively based on either transformationally invariant operators or symmetric operations have recently been introduced by the authors. In this study, we further propose to compose a geared rotationally identical CNN system (GRI-CNN) with a small step angle by connecting networks of participated processes at the first flatten layer. Using an ordinary CNN structure as a base, requirements for constructing a GRI-CNN include the use of either symmetric input vector or kernels with an angle increment that can form a complete cycle as a "gearwheel". Four basic GRI-CNN structures were studied. Each of them can produce quantitatively identical output results when a rotation angle of the input vector is evenly divisible by the step angle of the gear. Our study showed when an input vector rotated with an angle does not match to a step angle, the GRI-CNN can also produce a highly consistent result. With a design of using an ultra-fine gear-tooth step angle (e.g., 1 degree or 0.1 degree), all four GRI-CNN systems can be constructed virtually isotropically.