Chenyang Li

CV
h-index7
3papers
26citations
Novelty42%
AI Score39

3 Papers

9.1CVJul 26, 2023Code
Tracking Anything in High Quality

Jiawen Zhu, Zhenyu Chen, Zeqi Hao et al.

Visual object tracking is a fundamental video task in computer vision. Recently, the notably increasing power of perception algorithms allows the unification of single/multiobject and box/mask-based tracking. Among them, the Segment Anything Model (SAM) attracts much attention. In this report, we propose HQTrack, a framework for High Quality Tracking anything in videos. HQTrack mainly consists of a video multi-object segmenter (VMOS) and a mask refiner (MR). Given the object to be tracked in the initial frame of a video, VMOS propagates the object masks to the current frame. The mask results at this stage are not accurate enough since VMOS is trained on several closeset video object segmentation (VOS) datasets, which has limited ability to generalize to complex and corner scenes. To further improve the quality of tracking masks, a pretrained MR model is employed to refine the tracking results. As a compelling testament to the effectiveness of our paradigm, without employing any tricks such as test-time data augmentations and model ensemble, HQTrack ranks the 2nd place in the Visual Object Tracking and Segmentation (VOTS2023) challenge. Code and models are available at https://github.com/jiawen-zhu/HQTrack.

3.6CVOct 6, 2025
Improving the Spatial Resolution of GONG Solar Images to GST Quality Using Deep Learning

Chenyang Li, Qin Li, Haimin Wang et al.

High-resolution (HR) solar imaging is crucial for capturing fine-scale dynamic features such as filaments and fibrils. However, the spatial resolution of the full-disk H$α$ images is limited and insufficient to resolve these small-scale structures. To address this, we propose a GAN-based superresolution approach to enhance low-resolution (LR) full-disk H$α$ images from the Global Oscillation Network Group (GONG) to a quality comparable with HR observations from the Big Bear Solar Observatory/Goode Solar Telescope (BBSO/GST). We employ Real-ESRGAN with Residual-in-Residual Dense Blocks and a relativistic discriminator. We carefully aligned GONG-GST pairs. The model effectively recovers fine details within sunspot penumbrae and resolves fine details in filaments and fibrils, achieving an average mean squared error (MSE) of 467.15, root mean squared error (RMSE) of 21.59, and cross-correlation (CC) of 0.7794. Slight misalignments between image pairs limit quantitative performance, which we plan to address in future work alongside dataset expansion to further improve reconstruction quality.

8.7CVJun 6, 2024Code
Class-Aware Cartilage Segmentation for Autonomous US-CT Registration in Robotic Intercostal Ultrasound Imaging

Zhongliang Jiang, Yunfeng Kang, Yuan Bi et al.

Ultrasound imaging has been widely used in clinical examinations owing to the advantages of being portable, real-time, and radiation-free. Considering the potential of extensive deployment of autonomous examination systems in hospitals, robotic US imaging has attracted increased attention. However, due to the inter-patient variations, it is still challenging to have an optimal path for each patient, particularly for thoracic applications with limited acoustic windows, e.g., intercostal liver imaging. To address this problem, a class-aware cartilage bone segmentation network with geometry-constraint post-processing is presented to capture patient-specific rib skeletons. Then, a dense skeleton graph-based non-rigid registration is presented to map the intercostal scanning path from a generic template to individual patients. By explicitly considering the high-acoustic impedance bone structures, the transferred scanning path can be precisely located in the intercostal space, enhancing the visibility of internal organs by reducing the acoustic shadow. To evaluate the proposed approach, the final path mapping performance is validated on five distinct CTs and two volunteer US data, resulting in ten pairs of CT-US combinations. Results demonstrate that the proposed graph-based registration method can robustly and precisely map the path from CT template to individual patients (Euclidean error: $2.21\pm1.11~mm$).