4.4IVFeb 14, 2021
Attention-gated convolutional neural networks for off-resonance correction of spiral real-time MRIYongwan Lim, Shrikanth S. Narayanan, Krishna S. Nayak
Spiral acquisitions are preferred in real-time MRI because of their efficiency, which has made it possible to capture vocal tract dynamics during natural speech. A fundamental limitation of spirals is blurring and signal loss due to off-resonance, which degrades image quality at air-tissue boundaries. Here, we present a new CNN-based off-resonance correction method that incorporates an attention-gate mechanism. This leverages spatial and channel relationships of filtered outputs and improves the expressiveness of the networks. We demonstrate improved performance with the attention-gate, on 1.5 Tesla spiral speech RT-MRI, compared to existing off-resonance correction methods.
6.3IVJul 30, 2019
Robust Autocalibrated Structured Low-Rank EPI Ghost CorrectionRodrigo A. Lobos, W. Scott Hoge, Ahsan Javed et al.
Purpose: We propose and evaluate a new structured low-rank method for EPI ghost correction called Robust Autocalibrated LORAKS (RAC-LORAKS). The method can be used to suppress EPI ghosts arising from the differences between different readout gradient polarities and/or the differences between different shots. It does not require conventional EPI navigator signals, and is robust to imperfect autocalibration data. Methods: Autocalibrated LORAKS is a previous structured low-rank method for EPI ghost correction that uses GRAPPA-type autocalibration data to enable high-quality ghost correction. This method works well when the autocalibration data is pristine, but performance degrades substantially when the autocalibration information is imperfect. RAC-LORAKS generalizes Autocalibrated LORAKS in two ways. First, it does not completely trust the information from autocalibration data, and instead considers the autocalibration and EPI data simultaneously when estimating low-rank matrix structure. And second, it uses complementary information from the autocalibration data to improve EPI reconstruction in a multi-contrast joint reconstruction framework. RAC-LORAKS is evaluated using simulations and in vivo data, including comparisons to state-of-the-art methods. Results: RAC-LORAKS is demonstrated to have good ghost elimination performance compared to state-of-the-art methods in several complicated EPI acquisition scenarios (including gradient-echo brain imaging, diffusion-encoded brain imaging, and cardiac imaging). Conclusion: RAC-LORAKS provides effective suppression of EPI ghosts and is robust to imperfect autocalibration data.
4.6CVDec 10, 2018
Accuracy, Uncertainty, and Adaptability of Automatic Myocardial ASL Segmentation using Deep CNNHung P. Do, Yi Guo, Andrew J. Yoon et al.
PURPOSE: To apply deep CNN to the segmentation task in myocardial arterial spin labeled (ASL) perfusion imaging and to develop methods that measure uncertainty and that adapt the CNN model to a specific false positive vs. false negative tradeoff. METHODS: The Monte Carlo dropout (MCD) U-Net was trained on data from 22 subjects and tested on data from 6 heart transplant recipients. Manual segmentation and regional myocardial blood flow (MBF) were available for comparison. We consider two global uncertainty measures, named Dice Uncertainty and MCD Uncertainty, which were calculated with and without the use of manual segmentation, respectively. Tversky loss function with a hyperparameter $β$ was used to adapt the model to a specific false positive vs. false negative tradeoff. RESULTS: The MCD U-Net achieved Dice coefficient of mean(std) = 0.91(0.04) on the test set. MBF measured using automatic segmentations was highly correlated to that measured using the manual segmentation ($R^2$ = 0.96). Dice Uncertainty and MCD Uncertainty were in good agreement ($R^2$ = 0.64). As $β$ increased, the false positive rate systematically decreased and false negative rate systematically increased. CONCLUSION: We demonstrate the feasibility of deep CNN for automatic segmentation of myocardial ASL, with good accuracy. We also introduce two simple methods for assessing model uncertainty. Finally, we demonstrate the ability to adapt the CNN model to a specific false positive vs. false negative tradeoff. These findings are directly relevant to automatic segmentation in quantitative cardiac MRI and are broadly applicable to automatic segmentation problems in diagnostic imaging.