Réjean Fontaine

2papers

2 Papers

17.3LGJun 2
Learning to See via Epiretinal Implant Stimulation in silico with Model-Based Deep Reinforcement Learning

Jacob Lavoie, Marwan Besrour, William Lemaire et al.

Objective: Diseases such as age-related macular degeneration and retinitis pigmentosa cause the degradation of the photoreceptor layer. One approach to restore vision is to electrically stimulate the surviving retinal ganglion cells with a microelectrode array such as epiretinal implants. Epiretinal implants are known to generate visible anisotropic shapes elongated along the axon fascicles of neighboring retinal ganglion cells. Recent work has demonstrated that to obtain isotropic pixel-like shapes, it is possible to map axon fascicles and avoid stimulating them by inactivating electrodes or lowering stimulation current levels. Avoiding axon fascicle stimulation aims to remove brushstroke-like shapes in favor of a more reduced set of pixel-like shapes. Approach: In this study, we propose the use of isotropic and anisotropic shapes to render intelligible images on the retina of a virtual patient in a reinforcement learning environment named rlretina. The environment formalizes the task as using brushstrokes in a stroke-based rendering task. Main Results: We train a deep reinforcement learning agent that learns to assemble isotropic and anisotropic shapes to form an image. We investigate which error-based or perception-based metrics is adequate to reward the agent. The agent is trained in a model-based data generation fashion using the psychophysically validated axon map model to render images as perceived by different virtual patients. We show that the agent can generate more intelligible images compared to the naive method in different virtual patients. Significance: This work shares a new way to address epiretinal stimulation that constitutes a first step towards improving visual acuity in artificially-restored vision using anisotropic phosphenes.

AIJun 16, 2014
Automatic Channel Fault Detection and Diagnosis System for a Small Animal APD-Based Digital PET Scanner

Jonathan Charest, Jean-François Beaudoin, Jules Cadorette et al.

Fault detection and diagnosis is critical to many applications in order to ensure proper operation and performance over time. Positron emission tomography (PET) systems that require regular calibrations by qualified scanner operators are good candidates for such continuous improvements. Furthermore, for scanners employing one-to-one coupling of crystals to photodetectors to achieve enhanced spatial resolution and contrast, the calibration task is even more daunting because of the large number of independent channels involved. To cope with the additional complexity of the calibration and quality control procedures of these scanners, an intelligent system (IS) was designed to perform fault detection and diagnosis (FDD) of malfunctioning channels. The IS can be broken down into four hierarchical modules: parameter extraction, channel fault detection, fault prioritization and diagnosis. Of these modules, the first two have previously been reported and this paper focuses on fault prioritization and diagnosis. The purpose of the fault prioritization module is to help the operator to zero in on the faults that need immediate attention. The fault diagnosis module will then identify the causes of the malfunction and propose an explanation of the reasons that lead to the diagnosis. The FDD system was implemented on a LabPET avalanche photodiode (APD)-based digital PET scanner. Experiments demonstrated a FDD Sensitivity of 99.3 % (with a 95% confidence interval (CI) of: [98.7, 99.9]) for major faults. Globally, the Balanced Accuracy of the diagnosis for varying fault severities is 92 %. This suggests the IS can greatly benefit the operators in their maintenance task.