Julius Hannink

h-index14
2papers
1,026citations

2 Papers

11.3LGSep 12, 2016
Sensor-based Gait Parameter Extraction with Deep Convolutional Neural Networks

Julius Hannink, Thomas Kautz, Cristian F. Pasluosta et al.

Measurement of stride-related, biomechanical parameters is the common rationale for objective gait impairment scoring. State-of-the-art double integration approaches to extract these parameters from inertial sensor data are, however, limited in their clinical applicability due to the underlying assumptions. To overcome this, we present a method to translate the abstract information provided by wearable sensors to context-related expert features based on deep convolutional neural networks. Regarding mobile gait analysis, this enables integration-free and data-driven extraction of a set of 8 spatio-temporal stride parameters. To this end, two modelling approaches are compared: A combined network estimating all parameters of interest and an ensemble approach that spawns less complex networks for each parameter individually. The ensemble approach is outperforming the combined modelling in the current application. On a clinically relevant and publicly available benchmark dataset, we estimate stride length, width and medio-lateral change in foot angle up to ${-0.15\pm6.09}$ cm, ${-0.09\pm4.22}$ cm and ${0.13 \pm 3.78^\circ}$ respectively. Stride, swing and stance time as well as heel and toe contact times are estimated up to ${\pm 0.07}$, ${\pm0.05}$, ${\pm 0.07}$, ${\pm0.07}$ and ${\pm0.12}$ s respectively. This is comparable to and in parts outperforming or defining state-of-the-art. Our results further indicate that the proposed change in methodology could substitute assumption-driven double-integration methods and enable mobile assessment of spatio-temporal stride parameters in clinically critical situations as e.g. in the case of spastic gait impairments.

4.9CVFeb 20, 2014
Vesselness via Multiple Scale Orientation Scores

Julius Hannink, Remco Duits, Erik Bekkers

The multi-scale Frangi vesselness filter is an established tool in (retinal) vascular imaging. However, it cannot cope with crossings or bifurcations, since it only looks for elongated structures. Therefore, we disentangle crossing structures in the image via (multiple scale) invertible orientation scores. The described vesselness filter via scale-orientation scores performs considerably better at enhancing vessels throughout crossings and bifurcations than the Frangi version. Both methods are evaluated on a public dataset. Performance is measured by comparing ground truth data to the segmentation results obtained by basic thresholding and morphological component analysis of the filtered images.