Méziane Ait Ziane, Michel Zasadzinski, Cédric Join et al.
Our objective is to study the performance and robustness of the model-free strategy for controlling the oxygen stoichiometry of a fuel cell air supply system with a proton exchange membrane. After reviewing the literature on modeling and control of this process, the model-free approach appears to be a good candidate because, on the one hand, it allows straightforward real-time adaptation to track operating points and, on the other hand, it requires a low computational burden, which is attractive for industrial applications. Numerical simulations for two scenarios (constant and variable oxygen stoichiometry) with two current profiles reveal satisfactory performance of the model-free control law. The robustness is addressed by considering significant variations in the parameters of the proton exchange membrane air supply system.