Mehmet Yigit Avci

CV
h-index10
7papers
9citations
Novelty58%
AI Score50

7 Papers

IVJul 4, 2024Code
Unsupervised Analysis of Alzheimer's Disease Signatures using 3D Deformable Autoencoders

Mehmet Yigit Avci, Emily Chan, Veronika Zimmer et al.

With the increasing incidence of neurodegenerative diseases such as Alzheimer's Disease (AD), there is a need for further research that enhances detection and monitoring of the diseases. We present MORPHADE (Morphological Autoencoders for Alzheimer's Disease Detection), a novel unsupervised learning approach which uses deformations to allow the analysis of 3D T1-weighted brain images. To the best of our knowledge, this is the first use of deformations with deep unsupervised learning to not only detect, but also localize and assess the severity of structural changes in the brain due to AD. We obtain markedly higher anomaly scores in clinically important areas of the brain in subjects with AD compared to healthy controls, showcasing that our method is able to effectively locate AD-related atrophy. We additionally observe a visual correlation between the severity of atrophy highlighted in our anomaly maps and medial temporal lobe atrophy scores evaluated by a clinical expert. Finally, our method achieves an AUROC of 0.80 in detecting AD, out-performing several supervised and unsupervised baselines. We believe our framework shows promise as a tool towards improved understanding, monitoring and detection of AD. To support further research and application, we have made our code publicly available at github.com/ci-ber/MORPHADE.

CVDec 8, 2025
DIST-CLIP: Arbitrary Metadata and Image Guided MRI Harmonization via Disentangled Anatomy-Contrast Representations

Mehmet Yigit Avci, Pedro Borges, Virginia Fernandez et al.

Deep learning holds immense promise for transforming medical image analysis, yet its clinical generalization remains profoundly limited. A major barrier is data heterogeneity. This is particularly true in Magnetic Resonance Imaging, where scanner hardware differences, diverse acquisition protocols, and varying sequence parameters introduce substantial domain shifts that obscure underlying biological signals. Data harmonization methods aim to reduce these instrumental and acquisition variability, but existing approaches remain insufficient. When applied to imaging data, image-based harmonization approaches are often restricted by the need for target images, while existing text-guided methods rely on simplistic labels that fail to capture complex acquisition details or are typically restricted to datasets with limited variability, failing to capture the heterogeneity of real-world clinical environments. To address these limitations, we propose DIST-CLIP (Disentangled Style Transfer with CLIP Guidance), a unified framework for MRI harmonization that flexibly uses either target images or DICOM metadata for guidance. Our framework explicitly disentangles anatomical content from image contrast, with the contrast representations being extracted using pre-trained CLIP encoders. These contrast embeddings are then integrated into the anatomical content via a novel Adaptive Style Transfer module. We trained and evaluated DIST-CLIP on diverse real-world clinical datasets, and showed significant improvements in performance when compared against state-of-the-art methods in both style translation fidelity and anatomical preservation, offering a flexible solution for style transfer and standardizing MRI data. Our code and weights will be made publicly available upon publication.

CVNov 1, 2025
Metadata-Aligned 3D MRI Representations for Contrast Understanding and Quality Control

Mehmet Yigit Avci, Pedro Borges, Virginia Fernandez et al.

Magnetic Resonance Imaging suffers from substantial data heterogeneity and the absence of standardized contrast labels across scanners, protocols, and institutions, which severely limits large-scale automated analysis. A unified representation of MRI contrast would enable a wide range of downstream utilities, from automatic sequence recognition to harmonization and quality control, without relying on manual annotations. To this end, we introduce MR-CLIP, a metadata-guided framework that learns MRI contrast representations by aligning volumetric images with their DICOM acquisition parameters. The resulting embeddings shows distinct clusters of MRI sequences and outperform supervised 3D baselines under data scarcity in few-shot sequence classification. Moreover, MR-CLIP enables unsupervised data quality control by identifying corrupted or inconsistent metadata through image-metadata embedding distances. By transforming routinely available acquisition metadata into a supervisory signal, MR-CLIP provides a scalable foundation for label-efficient MRI analysis across diverse clinical datasets.

IVNov 3, 2023
Simulation of acquisition shifts in T2 Flair MR images to stress test AI segmentation networks

Christiane Posselt, Mehmet Yigit Avci, Mehmet Yigitsoy et al.

Purpose: To provide a simulation framework for routine neuroimaging test data, which allows for "stress testing" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid attenuated inversion recovery (FLAIR) Magnetic Resonance Imaging (MRI) protocols. Approach: The approach simulates "acquisition shift derivatives" of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art MS lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI). Results: The differences between real and simulated images range up to 19 % in gray and white matter for extreme parameter settings. For the segmentation networks under test the F1 score dependency on TE and TI can be well described by quadratic model functions (R^2 > 0.9). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI. Conclusions: We show that these deviations are in the range of values as may be caused by erroneous or individual differences of relaxation times as described by literature. The coefficients of the F1 model function allow for quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with the low baseline signal (like CSF) and when the protocol contains contrast-affecting measures that cannot be modelled due to missing information in the DICOM header.

CVJun 23, 2025Code
MR-CLIP: Efficient Metadata-Guided Learning of MRI Contrast Representations

Mehmet Yigit Avci, Pedro Borges, Paul Wright et al.

Accurate interpretation of Magnetic Resonance Imaging scans in clinical systems is based on a precise understanding of image contrast. This contrast is primarily governed by acquisition parameters, such as echo time and repetition time, which are stored in the DICOM metadata. To simplify contrast identification, broad labels such as T1-weighted or T2-weighted are commonly used, but these offer only a coarse approximation of the underlying acquisition settings. In many real-world datasets, such labels are entirely missing, leaving raw acquisition parameters as the only indicators of contrast. Adding to this challenge, the available metadata is often incomplete, noisy, or inconsistent. The lack of reliable and standardized metadata complicates tasks such as image interpretation, retrieval, and integration into clinical workflows. Furthermore, robust contrast-aware representations are essential to enable more advanced clinical applications, such as achieving modality-invariant representations and data harmonization. To address these challenges, we propose MR-CLIP, a multimodal contrastive learning framework that aligns MR images with their DICOM metadata to learn contrast-aware representations, without relying on manual labels. Trained on a diverse clinical dataset that spans various scanners and protocols, MR-CLIP captures contrast variations across acquisitions and within scans, enabling anatomy-invariant representations. We demonstrate its effectiveness in cross-modal retrieval and contrast classification, highlighting its scalability and potential for further clinical applications. The code and weights are publicly available at https://github.com/myigitavci/MR-CLIP.

CVMar 4
Understanding Sources of Demographic Predictability in Brain MRI via Disentangling Anatomy and Contrast

Mehmet Yigit Avci, Akshit Achara, Andrew King et al.

Demographic attributes such as age, sex, and race can be predicted from medical images, raising concerns about bias in clinical AI systems. In brain MRI, this signal may arise from anatomical variation, acquisition-dependent contrast differences, or both, yet these sources remain entangled in conventional analyses. Without disentangling them, mitigation strategies risk failing to address the underlying causes. We propose a controlled framework based on disentangled representation learning, decomposing brain MRI into anatomy-focused representations that suppress acquisition influence and contrast embeddings that capture acquisition-dependent characteristics. Training predictive models for age, sex, and race on full images, anatomical representations, and contrast-only embeddings allows us to quantify the relative contributions of structure and acquisition to the demographic signal. Across three datasets and multiple MRI sequences, we find that demographic predictability is primarily rooted in anatomical variation: anatomy-focused representations largely preserve the performance of models trained on raw images. Contrast-only embeddings retain a weaker but systematic signal that is dataset-specific and does not generalise across sites. These findings suggest that effective mitigation must explicitly account for the distinct anatomical and acquisition-dependent origins of the demographic signal, ensuring that any bias reduction generalizes robustly across domains.

IVDec 2, 2021
Improving accuracy and uncertainty quantification of deep learning based quantitative MRI using Monte Carlo dropout

Mehmet Yigit Avci, Ziyu Li, Qiuyun Fan et al.

Dropout is conventionally used during the training phase as regularization method and for quantifying uncertainty in deep learning. We propose to use dropout during training as well as inference steps, and average multiple predictions to improve the accuracy, while reducing and quantifying the uncertainty. The results are evaluated for fractional anisotropy (FA) and mean diffusivity (MD) maps which are obtained from only 3 direction scans. With our method, accuracy can be improved significantly compared to network outputs without dropout, especially when the training dataset is small. Moreover, confidence maps are generated which may aid in diagnosis of unseen pathology or artifacts.