5.1IVMay 23, 2025
MRI Image Generation Based on Text PromptsXinxian Fan, Mengye Lyu
This study explores the use of text-prompted MRI image generation with the Stable Diffusion (SD) model to address challenges in acquiring real MRI datasets, such as high costs, limited rare case samples, and privacy concerns. The SD model, pre-trained on natural images, was fine-tuned using the 3T fastMRI dataset and the 0.3T M4Raw dataset, with the goal of generating brain T1, T2, and FLAIR images across different magnetic field strengths. The performance of the fine-tuned model was evaluated using quantitative metrics,including Fréchet Inception Distance (FID) and Multi-Scale Structural Similarity (MS-SSIM), showing improvements in image quality and semantic consistency with the text prompts. To further evaluate the model's potential, a simple classification task was carried out using a small 0.35T MRI dataset, demonstrating that the synthetic images generated by the fine-tuned SD model can effectively augment training datasets and improve the performance of MRI constrast classification tasks. Overall, our findings suggest that text-prompted MRI image generation is feasible and can serve as a useful tool for medical AI applications.
3.6IVNov 5, 2024
LDPM: Towards undersampled MRI reconstruction with MR-VAE and Latent Diffusion PriorXingjian Tang, Jingwei Guan, Linge Li et al.
Diffusion models, as powerful generative models, have found a wide range of applications and shown great potential in solving image reconstruction problems. Some works attempted to solve MRI reconstruction with diffusion models, but these methods operate directly in pixel space, leading to higher computational costs for optimization and inference. Latent diffusion models, pre-trained on natural images with rich visual priors, are expected to solve the high computational cost problem in MRI reconstruction by operating in a lower-dimensional latent space. However, direct application to MRI reconstruction faces three key challenges: (1) absence of explicit control mechanisms for medical fidelity, (2) domain gap between natural images and MR physics, and (3) undefined data consistency in latent space. To address these challenges, a novel Latent Diffusion Prior-based undersampled MRI reconstruction (LDPM) method is proposed. Our LDPM framework addresses these challenges by: (1) a sketch-guided pipeline with a two-step reconstruction strategy, which balances perceptual quality and anatomical fidelity, (2) an MRI-optimized VAE (MR-VAE), which achieves an improvement of approximately 3.92 dB in PSNR for undersampled MRI reconstruction compared to that with SD-VAE \cite{sd}, and (3) Dual-Stage Sampler, a modified version of spaced DDPM sampler, which enforces high-fidelity reconstruction in the latent space. Experiments on the fastMRI dataset\cite{fastmri} demonstrate the state-of-the-art performance of the proposed method and its robustness across various scenarios. The effectiveness of each module is also verified through ablation experiments.