71.9CVMay 17Code
VISTA: Variance-Gated Inter-Sequence Test-Time Adaptation for Multi-Sequence MRI SegmentationZhipeng Deng, Jiale Zhou, Wenhan Jiang et al.
Deploying multi-sequence magnetic resonance imaging (MRI) segmentation models to new clinical environments is challenging due to variations in scanners and acquisition protocols. Although existing TTA methods handle basic per-modality shifts, they often fail under a fundamental dual-shift problem, as their adaptation signals fail to capture modality-interaction shifts that disrupt inter-sequence consistency. To address this, we propose Variance-gated Inter-Sequence Test-time Adaptation (VISTA), a source-free framework that tackles modality-interaction shifts. First, we design an Inter-Sequence Intervention Generator (ISIG) that generates a set of consistency probes by swapping low-frequency spectra and entropy-localized patches across sequences, preserving anatomical semantics while challenging inter-sequence dependencies. Second, we introduce Cross-View Disagreement-Aware Pseudo Labeling (CDPL), which establishes a voxel-wise reliability metric using cross-view disagreement variance to dynamically gate self-training and enforce interventional consistency, encouraging the network to rely on robust anatomical semantics. Extensive experiments adapting from standard adult MRI (BraTS-GLI-Pre) to African low-field (BraTS-SSA) and pediatric (BraTS-PED) cohorts show improved performance over competing methods under clinical shifts, achieving absolute Dice improvements of +1.89% (SSA) and +2.82% (PED) over the source model. The code is available at https://github.com/dzp2095/VISTA.
26.8CVMay 17Code
VoxShield: Protecting 3D Medical Datasets from Unauthorized Training via Frequency-Aware Inter-Slice DisruptionXinyao Liu, Zhipeng Deng, Wenhan Jiang et al.
The release of public 3D medical image segmentation (MIS) datasets accelerates clinical research but simultaneously heightens risks of unauthorized AI model training. While Unlearnable Examples (UE) offer protection by injecting imperceptible perturbations to prevent effective model learning, existing methods primarily target 2D scenarios. They neglect the volumetric spatial correlations and inter-slice anatomical consistency inherent in 3D medical volumes, which serve as critical learning priors for 3D segmentation networks. To bridge this gap, we propose VoxShield, a UE framework that explicitly targets the volumetric inductive biases of 3D networks. Our core insight is that by systematically dismantling the cross-slice continuity that 3D architectures rely on, we can fundamentally impair their spatial aggregation process. Specifically, we introduce an Inter-Slice Frequency Consistency Disruption mechanism that maximizes the spectral divergence between adjacent slices, injecting structural incoherence along the $z$-axis. Complementing this structural attack, a Semantic Prediction Disruption module is incorporated. By maximizing the $\ell_1$ divergence between clean and perturbed logits, it forces the injected noise to penetrate the entire network and corrupt the final semantic mapping. Experiments on BraTS19 and FLARE21 demonstrate that VoxShield successfully degrades 3D segmentation performance, reducing the DSC from 80.0% to near 0.0% and from 88.6% to 6.8%, respectively. All protections are achieved with minimal perturbation ($ε=4/255$) to preserve high visual fidelity. The code is available at https://github.com/KK266299/VoxShield.