Aamir Akbar

h-index12
2papers
504citations

2 Papers

3.9CVJun 17
PEFT-MedSAM: Efficient Fine-Tuning of Medical Foundation Models for Explainable Skin Lesion Segmentation

Asad Channa, Abdullah Khan, Asghar Ali Chandio et al.

Automated segmentation of skin lesions using deep learning models for dermoscopic images can be very helpful in finding melanomas earlier than they would normally be detected. However, most deep learning methods available do not perform well. The aim of this paper is to present a parameter-efficient fine-tuning method called PEFT-MedSAM for adapting the Medical Segment Anything Model (MedSAM) to automatically segment dermoscopic skin lesions. The PEFT-MedSAM method uses only the lightweight mask decoder for training the model while keeping the pre-trained image encoder and prompt encoder frozen. The experiments performed on the ISIC 2018 benchmark dataset shows that PEFT-MedSAM obtains a dice coefficient of .9411 and an intersection over union value of .8918 when compared to both a fully trained U-Net baseline (.8715 dice coefficient) and zero-shot MedSAM inference (.8997 dice coefficient). The external validation of the model using PH2 dataset shows .9467 dice coefficient with +/- .0310 standard deviation. Supportive evidence for these claims include a p-value less than .0001 for Wilcoxon signed rank tests comparing the two datasets and bootstrap-estimated 95% confidence intervals of [.9364,.9447] that represent the estimated range of possible values for the average dice coefficient obtained by repeating the test. To increase clinical trustworthiness, we used Grad-CAM explainability along with a pointing game based evaluation methodology to evaluate the CNN baseline model on the validation set. The results showed that we had an accuracy rate of 98.27% on the validation set of 519 images and confirmed that the model classified regions containing skin lesions.

6.6CRApr 30, 2021
LightIoT: Lightweight and Secure Communication for Energy-Efficient IoT in Health Informatics

Mian Ahmad Jan, Fazlullah Khan, Spyridon Mastorakis et al.

Internet of Things (IoT) is considered as a key enabler of health informatics. IoT-enabled devices are used for in-hospital and in-home patient monitoring to collect and transfer biomedical data pertaining to blood pressure, electrocardiography (ECG), blood sugar levels, body temperature, etc. Among these devices, wearables have found their presence in a wide range of healthcare applications. These devices generate data in real-time and transmit them to nearby gateways and remote servers for processing and visualization. The data transmitted by these devices are vulnerable to a range of adversarial threats, and as such, privacy and integrity need to be preserved. In this paper, we present LightIoT, a lightweight and secure communication approach for data exchanged among the devices of a healthcare infrastructure. LightIoT operates in three phases: initialization, pairing, and authentication. These phases ensure the reliable transmission of data by establishing secure sessions among the communicating entities (wearables, gateways and a remote server). Statistical results exhibit that our scheme is lightweight, robust, and resilient against a wide range of adversarial attacks and incurs much lower computational and communication overhead for the transmitted data in the presence of existing approaches.