Julian Schmid

2papers

2 Papers

NAJan 13, 2015
Computational Realization of a Non-Equidistant Grid Sampling in Photoacoustics with a Non-Uniform FFT

Julian Schmid, Thomas Glatz, Behrooz Zabihian et al.

To obtain the initial pressure from the collected data on a planar sensor arrangement in Photoacoustic tomography, there exists an exact analytic frequency domain reconstruction formula. An efficient realization of this formula needs to cope with the evaluation of the datas Fourier transform on a non-equispaced mesh. In this paper, we use the non-uniform fast Fourier transform to handle this issue and show its feasibility in 3D experiments. This is done in comparison to the standard approach that uses polynomial interpolation. Moreover, we investigate the effect and the utility of flexible sensor location on the quality of photoacoustic image reconstruction. The computational realization is accomplished by the use of a multi-dimensional non-uniform fast Fourier algorithm, where non-uniform data sampling is performed both in frequency and spatial domain. We show that with appropriate sampling the imaging quality can be significantly improved. Reconstructions with synthetic and real data show the superiority of this method.

0.0CVMay 28
Low-Magnification SEM May Suffice: Interpretable Deep Learning for Multi-Scale Fracture-Cause Classification in Zirconia-Toughened Alumina

Julian Schmid, Pawel Astankow, Tom Vater et al.

Reliable identification of fracture origins in alumina matrix composite hip and knee implants is critical for quality assurance and patient safety, yet current fractographic workflows are time-consuming, partly subjective, and reliant on high-magnification scanning electron microscopy (SEM). We present an interpretable vision-transformer (ViT) workflow for automated classification of fracture causes in an alumina matrix composite (BIOLOX delta, CeramTec GmbH) widely used in total joint replacements. A dataset of 8,493 SEM images (50x-10,000x) was curated from five years of in-production burst and proof tests and annotated into three defect categories defined along the manufacturing chain: green body, hard machining, and material defects. Under severe class imbalance, the fine-tuned ViT reached an accuracy of 0.907 and a macro-F1 of 0.888 in stratified five-fold cross-validation, with a two-stage perceptual-hash/SSIM leakage audit confirming negligible specimen overlap. Notably, performance at low magnification (50x) was comparable to that at high magnification (1k-10kx), indicating that macro-scale features - mirror geometry and hackle line fields - already encode sufficient diagnostic signal. Grad-CAM attributions consistently localised on canonical fractographic cues (mirrors, hackles, pores, machining marks), aligning with established fractographic criteria. Together, these results position interpretable ViTs as a complementary tool for ceramic-implant quality assurance, enabling low-magnification pre-screening and reducing reliance on time-intensive high-magnification inspection.