18.8AINov 30, 2025Code
Med-CMR: A Fine-Grained Benchmark Integrating Visual Evidence and Clinical Logic for Medical Complex Multimodal ReasoningHaozhen Gong, Xiaozhong Ji, Yuansen Liu et al.
MLLMs MLLMs are beginning to appear in clinical workflows, but their ability to perform complex medical reasoning remains unclear. We present Med-CMR, a fine-grained Medical Complex Multimodal Reasoning benchmark. Med-CMR distinguishes from existing counterparts by three core features: 1) Systematic capability decomposition, splitting medical multimodal reasoning into fine-grained visual understanding and multi-step reasoning to enable targeted evaluation; 2) Challenging task design, with visual understanding across three key dimensions (small-object detection, fine-detail discrimination, spatial understanding) and reasoning covering four clinically relevant scenarios (temporal prediction, causal reasoning, long-tail generalization, multi-source integration); 3) Broad, high-quality data coverage, comprising 20,653 Visual Question Answering (VQA) pairs spanning 11 organ systems and 12 imaging modalities, validated via a rigorous two-stage (human expert + model-assisted) review to ensure clinical authenticity. We evaluate 18 state-of-the-art MLLMs with Med-CMR, revealing GPT-5 as the top-performing commercial model: 57.81 accuracy on multiple-choice questions (MCQs) and a 48.70 open-ended score, outperforming Gemini 2.5 Pro (49.87 MCQ accuracy, 45.98 open-ended score) and leading open-source model Qwen3-VL-235B-A22B (49.34 MCQ accuracy, 42.62 open-ended score). However, specialized medical MLLMs do not reliably outperform strong general models, and long-tail generalization emerges as the dominant failure mode. Med-CMR thus provides a stress test for visual-reasoning integration and rare-case robustness in medical MLLMs, and a rigorous yardstick for future clinical systems.
5.2CVDec 5, 2024
Exploring Real&Synthetic Dataset and Linear Attention in Image RestorationYuzhen Du, Teng Hu, Jiangning Zhang et al. · tencent-ai
Image restoration (IR) aims to recover high-quality images from degraded inputs, with recent deep learning advancements significantly enhancing performance. However, existing methods lack a unified training benchmark for iterations and configurations. We also identify a bias in image complexity distributions between commonly used IR training and testing datasets, resulting in suboptimal restoration outcomes. To address this, we introduce a large-scale IR dataset called ReSyn, which employs a novel image filtering method based on image complexity to ensure a balanced distribution and includes both real and AIGC synthetic images. We establish a unified training standard that specifies iterations and configurations for image restoration models, focusing on measuring model convergence and restoration capability. Additionally, we enhance transformer-based image restoration models using linear attention mechanisms by proposing RWKV-IR, which integrates linear complexity RWKV into the transformer structure, allowing for both global and local receptive fields. Instead of directly using Vision-RWKV, we replace the original Q-Shift in RWKV with a Depth-wise Convolution shift to better model local dependencies, combined with Bi-directional attention for comprehensive linear attention. We also introduce a Cross-Bi-WKV module that merges two Bi-WKV modules with different scanning orders for balanced horizontal and vertical attention. Extensive experiments validate the effectiveness of our RWKV-IR model.