NAFeb 14, 2017
Real-time Error Control for Surgical SimulationHuu Phuoc Bui, Satyendra Tomar, Hadrien Courtecuisse et al.
Objective: To present the first real-time a posteriori error-driven adaptive finite element approach for real-time simulation and to demonstrate the method on a needle insertion problem. Methods: We use corotational elasticity and a frictional needle/tissue interaction model. The problem is solved using finite elements within SOFA. The refinement strategy relies upon a hexahedron-based finite element method, combined with a posteriori error estimation driven local $h$-refinement, for simulating soft tissue deformation. Results: We control the local and global error level in the mechanical fields (e.g. displacement or stresses) during the simulation. We show the convergence of the algorithm on academic examples, and demonstrate its practical usability on a percutaneous procedure involving needle insertion in a liver. For the latter case, we compare the force displacement curves obtained from the proposed adaptive algorithm with that obtained from a uniform refinement approach. Conclusions: Error control guarantees that a tolerable error level is not exceeded during the simulations. Local mesh refinement accelerates simulations. Significance: Our work provides a first step to discriminate between discretization error and modeling error by providing a robust quantification of discretization error during simulations.
CEDec 8, 2017
Corotational Cut Finite Element Method for real-time surgical simulation: application to needle insertion simulationHuu Phuoc Bui, Satyendra Tomar, Stéphane P. A. Bordas
This paper describes the use of the corotational cut Finite Element Method (FEM) for real-time surgical simulation. Users only need to provide a background mesh which is not necessarily conforming to the boundaries/interfaces of the simulated object. The details of the surface, which can be directly obtained from binary images, are taken into account by a multilevel embedding algorithm applied to elements of the background mesh that cut by the surface. Boundary conditions can be implicitly imposed on the surface using Lagrange multipliers. The implementation is verified by convergence studies with optimal rates. The algorithm is applied to various needle insertion simulations (e.g. for biopsy or brachytherapy) into brain and liver to verify the reliability of method, and numerical results show that the present method can make the discretisation independent from geometric description, and can avoid the complexity of mesh generation of complex geometries while retaining the accuracy of the standard FEM. Using the proposed approach is very suitable for real-time and patient specific simulations as it improves the simulation accuracy by taking into account automatically and properly the simulated geometry.