ARGUS: Accelerated, Robust, General, and Unsupervised Cell Tracking SolutionsNoah Jaitner, Kandice Tanner, Ingolf Sack et al.
Background and Objective: Quantitative analysis of cell dynamics is central to modern biological research, providing critical insights into immune cell interactions, disease progression, and drug mechanisms. Automated cell tracking in time-lapse microscopy remains challenging due to noise, morphological variations, overlapping cells, and dynamic events such as divisions and fusions. Methods: We present ARGUS, a framework for Accelerated, Robust, General, and Unsupervised Cell Tracking Solutions. ARGUS combines adaptive cell detection, dense Farneback optical-flow prediction, frame-to-frame linear assignment, and a sequence-level tracklet-refinement step that reconnects trajectory fragments across short temporal gaps. Results: On publicly available Cell Tracking Challenge datasets, ARGUS achieved detection accuracy of 0.905-0.971 and tracking accuracy of 0.897-0.964, with runtimes within 1 minute (5-6 seconds for 3 frames). Conclusions: ARGUS is a modular, interpretable framework that can be adapted to different imaging modalities and biological applications without training data or GPU infrastructure. The implementation is publicly available at https://github.com/Gitinc/argus
2.4IVJun 21, 2021
Fully automated quantification of in vivo viscoelasticity of prostate zones using magnetic resonance elastography with Dense U-net segmentationNader Aldoj, Federico Biavati, Marc Dewey et al.
Magnetic resonance elastography (MRE) for measuring viscoelasticity heavily depends on proper tissue segmentation, especially in heterogeneous organs such as the prostate. Using trained network-based image segmentation, we investigated if MRE data suffice to extract anatomical and viscoelastic information for automatic tabulation of zonal mechanical properties of the prostate. Overall, 40 patients with benign prostatic hyperplasia (BPH) or prostate cancer (PCa) were examined with three magnetic resonance imaging (MRI) sequences: T2-weighted MRI (T2w), diffusion-weighted imaging (DWI), and MRE-based tomoelastography yielding six independent sets of imaging data per patient (T2w, DWI, apparent diffusion coefficient (ADC), MRE magnitude, shear wave speed, and loss angle maps). Combinations of these data were used to train Dense U-nets with manually segmented masks of the entire prostate gland (PG), central zone (CZ), and peripheral zone (PZ) in 30 patients and to validate them in 10 patients. Dice score (DS), sensitivity, specificity, and Hausdorff distance were determined. We found that segmentation based on MRE magnitude maps alone (DS, PG: 0.93$\pm$0.04, CZ: 0.95$\pm$0.03, PZ: 0.77$\pm$0.05) was more accurate than magnitude maps combined with T2w and DWI_b (DS, PG: 0.91$\pm$0.04, CZ: 0.91$\pm$0.06, PZ: 0.63$\pm$0.16) or T2w alone (DS, PG: 0.92$\pm$0.03, CZ: 0.91$\pm$0.04, PZ: 0.65$\pm$0.08). Automatically tabulated MRE values were not different from ground-truth values (P>0.05). In conclusion: MRE combined with Dense U-net segmentation allows tabulation of quantitative imaging markers without manual analysis and independent of other MRI sequences and can thus contribute to PCa detection and classification.