Due to wavelength dependent light absorption and scattering, underwater images usually suffer from color distortion and blurred details, which limits underwater object detection performance. Existing underwater image enhancement methods mainly focus on visual quality improvement, while it is still difficult to balance enhancement quality, processing efficiency, and downstream detection performance. Therefore, this paper proposes an efficient dual-branch underwater image enhancement framework for object detection. The detail enhancement branch improves brightness and local contrast to recover texture details in dark regions. The color restoration branch uses adaptive compensation to reduce color distortion and improve color gradation. By combining the complementary outputs of the two branches, the proposed framework provides clearer and more informative images for object detection. On the UIEB and EUVP datasets, the proposed method achieves UIQM scores of 2.249 and 2.576. When applied to the YOLOv8 detection task on the URPC dataset, the proposed method improves mAP50 by 2.1\% compared with the baseline. Extensive experiments show that our method improves object detection in complex underwater scenes, while balancing enhancement quality and processing efficiency.

7.2SYJun 13
Data Center Life Cycle Co-Design Optimization

Shrenik Jadhav, Vidhyashree Nagaraju, Zheng Liu

Liquid cooled supercomputers dissipate tens of megawatts of waste heat through cooling plants organized as parallel subloops that serve coolant distribution units. The number of subloops and the assignment of units to them are design decisions fixed at construction, yet they have not been systematically optimized for facilities at this scale. As electricity grids decarbonize, embodied carbon becomes a larger share of facility life cycle emissions and the cost of an unnecessary subloop becomes harder to justify. We present a framework that integrates operational energy from a validated control optimizer based on sequential least squares programming, embodied carbon from a bill of materials, and expected unplanned downtime from a per subloop reliability model. The framework is applied to the Frontier supercomputer, evaluating all 611 ways of partitioning its 25 coolant distribution units into two through six subloops. The life cycle cost and carbon optimum is found at two subloops holding 14 and 11 units, achieving 3,320.7 tonnes of carbon dioxide equivalent and $3.99 million over a seven year horizon, a saving of 50.2 tonnes and $100,000 compared to built four subloop configuration. The optimum remains on the Pareto front in all 15 scenarios of a one at a time sensitivity sweep. A semi-analytical decision rule generalizes the result, predicting four subloops for Aurora, two for El Capitan, and one for LUMI. When reliability is treated as a hard constraint set by operations policy, the four subloop Frontier deployment is consistent with the constrained optimum.