Shimaa El-Bana

h-index5
2papers
133citations

2 Papers

3.6CVDec 16, 2025
XAI-Driven Diagnosis of Generalization Failure in State-Space Cerebrovascular Segmentation Models: A Case Study on Domain Shift Between RSNA and TopCoW Datasets

Youssef Abuzeid, Shimaa El-Bana, Ahmad Al-Kabbany

The clinical deployment of deep learning models in medical imaging is severely hindered by domain shift. This challenge, where a high-performing model fails catastrophically on external datasets, is a critical barrier to trustworthy AI. Addressing this requires moving beyond simple performance metrics toward deeper understanding, making Explainable AI (XAI) an essential diagnostic tool in medical image analysis. We present a rigorous, two-phase approach to diagnose the generalization failure of state-of-the-art State-Space Models (SSMs), specifically UMamaba, applied to cerebrovascular segmentation. We first established a quantifiable domain gap between our Source (RSNA CTA Aneurysm) and Target (TopCoW Circle of Willis CT) datasets, noting significant differences in Z-resolution and background noise. The model's Dice score subsequently plummeted from 0.8604 (Source) to 0.2902 (Target). In the second phase, which is our core contribution, we utilized Seg-XRes-CAM to diagnose the cause of this failure. We quantified the model's focus by measuring the overlap between its attention maps and the Ground Truth segmentations, and between its attention maps and its own Prediction Mask. Our analysis proves the model failed to generalize because its attention mechanism abandoned true anatomical features in the Target domain. Quantitative metrics confirm the model's focus shifted away from the Ground Truth vessels (IoU~0.101 at 0.3 threshold) while still aligning with its own wrong predictions (IoU~0.282 at 0.3 threshold). This demonstrates the model learned spurious correlations, confirming XAI is a powerful diagnostic tool for identifying dataset bias in emerging architectures.

6.2CVOct 4, 2025
Efficiency vs. Efficacy: Assessing the Compression Ratio-Dice Score Relationship through a Simple Benchmarking Framework for Cerebrovascular 3D Segmentation

Shimaa Elbana, Ahmad Kamal, Shahd Ahmed Ali et al.

The increasing size and complexity of medical imaging datasets, particularly in 3D formats, present significant barriers to collaborative research and transferability. This study investigates whether the ZFP compression technique can mitigate these challenges without compromising the performance of automated cerebrovascular segmentation, a critical first step in intracranial aneurysm detection. We apply ZFP in both its error tolerance and fixed-rate modes to a large scale, and one of the most recent, datasets in the literature, 3D medical dataset containing ground-truth vascular segmentations. The segmentation quality on the compressed volumes is rigorously compared to the uncompressed baseline (Dice approximately equals 0.8774). Our findings reveal that ZFP can achieve substantial data reduction--up to a 22.89:1 ratio in error tolerance mode--while maintaining a high degree of fidelity, with the mean Dice coefficient remaining high at 0.87656. These results demonstrate that ZFP is a viable and powerful tool for enabling more efficient and accessible research on large-scale medical datasets, fostering broader collaboration across the community.