Jason Granstedt

IV
h-index4
5papers
42citations
Novelty36%
AI Score36

5 Papers

2.4AIFeb 10
Image Quality in the Era of Artificial Intelligence

Jana G. Delfino, Jason L. Granstedt, Frank W. Samuelson et al.

Artificial intelligence (AI) is being deployed within radiology at a rapid pace. AI has proven an excellent tool for reconstructing and enhancing images that appear sharper, smoother, and more detailed, can be acquired more quickly, and allowing clinicians to review them more rapidly. However, incorporation of AI also introduces new failure modes and can exacerbate the disconnect between perceived quality of an image and information content of that image. Understanding the limitations of AI-enabled image reconstruction and enhancement is critical for safe and effective use of the technology. Hence, the purpose of this communication is to bring awareness to limitations when AI is used to reconstruct or enhance a radiological image, with the goal of enabling users to reap benefits of the technology while minimizing risks.

5.1IVAug 18, 2025
Hallucinations in medical devices

Jason Granstedt, Prabhat Kc, Rucha Deshpande et al.

Computer methods in medical devices are frequently imperfect and are known to produce errors in clinical or diagnostic tasks. However, when deep learning and data-based approaches yield output that exhibit errors, the devices are frequently said to hallucinate. Drawing from theoretical developments and empirical studies in multiple medical device areas, we introduce a practical and universal definition that denotes hallucinations as a type of error that is plausible and can be either impactful or benign to the task at hand. The definition aims at facilitating the evaluation of medical devices that suffer from hallucinations across product areas. Using examples from imaging and non-imaging applications, we explore how the proposed definition relates to evaluation methodologies and discuss existing approaches for minimizing the prevalence of hallucinations.

13.7IVJul 6, 2021
Impact of deep learning-based image super-resolution on binary signal detection

Xiaohui Zhang, Varun A. Kelkar, Jason Granstedt et al.

Deep learning-based image super-resolution (DL-SR) has shown great promise in medical imaging applications. To date, most of the proposed methods for DL-SR have only been assessed by use of traditional measures of image quality (IQ) that are commonly employed in the field of computer vision. However, the impact of these methods on objective measures of image quality that are relevant to medical imaging tasks remains largely unexplored. In this study, we investigate the impact of DL-SR methods on binary signal detection performance. Two popular DL-SR methods, the super-resolution convolutional neural network (SRCNN) and the super-resolution generative adversarial network (SRGAN), were trained by use of simulated medical image data. Binary signal-known-exactly with background-known-statistically (SKE/BKS) and signal-known-statistically with background-known-statistically (SKS/BKS) detection tasks were formulated. Numerical observers, which included a neural network-approximated ideal observer and common linear numerical observers, were employed to assess the impact of DL-SR on task performance. The impact of the complexity of the DL-SR network architectures on task-performance was quantified. In addition, the utility of DL-SR for improving the task-performance of sub-optimal observers was investigated. Our numerical experiments confirmed that, as expected, DL-SR could improve traditional measures of IQ. However, for many of the study designs considered, the DL-SR methods provided little or no improvement in task performance and could even degrade it. It was observed that DL-SR could improve the task-performance of sub-optimal observers under certain conditions. The presented study highlights the urgent need for the objective assessment of DL-SR methods and suggests avenues for improving their efficacy in medical imaging applications.

2.4IVJan 30, 2021
Advancing the AmbientGAN for learning stochastic object models

Weimin Zhou, Sayantan Bhadra, Frank J. Brooks et al.

Medical imaging systems are commonly assessed and optimized by use of objective-measures of image quality (IQ) that quantify the performance of an observer at specific tasks. Variation in the objects to-be-imaged is an important source of variability that can significantly limit observer performance. This object variability can be described by stochastic object models (SOMs). In order to establish SOMs that can accurately model realistic object variability, it is desirable to use experimental data. To achieve this, an augmented generative adversarial network (GAN) architecture called AmbientGAN has been developed and investigated. However, AmbientGANs cannot be immediately trained by use of advanced GAN training methods such as the progressive growing of GANs (ProGANs). Therefore, the ability of AmbientGANs to establish realistic object models is limited. To circumvent this, a progressively-growing AmbientGAN (ProAmGAN) has been proposed. However, ProAmGANs are designed for generating two-dimensional (2D) images while medical imaging modalities are commonly employed for imaging three-dimensional (3D) objects. Moreover, ProAmGANs that employ traditional generator architectures lack the ability to control specific image features such as fine-scale textures that are frequently considered when optimizing imaging systems. In this study, we address these limitations by proposing two advanced AmbientGAN architectures: 3D ProAmGANs and Style-AmbientGANs (StyAmGANs). Stylized numerical studies involving magnetic resonance (MR) imaging systems are conducted. The ability of 3D ProAmGANs to learn 3D SOMs from imaging measurements and the ability of StyAmGANs to control fine-scale textures of synthesized objects are demonstrated.

3.3SPMar 4, 2020
Approximating the Hotelling Observer with Autoencoder-Learned Efficient Channels for Binary Signal Detection Tasks

Jason L. Granstedt, Weimin Zhou, Mark A. Anastasio

The objective assessment of image quality (IQ) has been advocated for the analysis and optimization of medical imaging systems. One method of obtaining such IQ metrics is through a mathematical observer. The Bayesian ideal observer is optimal by definition for signal detection tasks, but is frequently both intractable and non-linear. As an alternative, linear observers are sometimes used for task-based image quality assessment. The optimal linear observer is the Hotelling observer (HO). The computational cost of calculating the HO increases with image size, making a reduction in the dimensionality of the data desirable. Channelized methods have become popular for this purpose, and many competing methods are available for computing efficient channels. In this work, a novel method for learning channels using an autoencoder (AE) is presented. AEs are a type of artificial neural network (ANN) that are frequently employed to learn concise representations of data to reduce dimensionality. Modifying the traditional AE loss function to focus on task-relevant information permits the development of efficient AE-channels. These AE-channels were trained and tested on a variety of signal shapes and backgrounds to evaluate their performance. In the experiments, the AE-learned channels were competitive with and frequently outperformed other state-of-the-art methods for approximating the HO. The performance gains were greatest for the datasets with a small number of training images and noisy estimates of the signal image. Overall, AEs are demonstrated to be competitive with state-of-the-art methods for generating efficient channels for the HO and can have superior performance on small datasets.