Siegfried Trattnig

CV
h-index28
4papers
15citations
Novelty46%
AI Score27

4 Papers

IVJun 17, 2022
Multi-scale Super-resolution Magnetic Resonance Spectroscopic Imaging with Adjustable Sharpness

Siyuan Dong, Gilbert Hangel, Wolfgang Bogner et al.

Magnetic Resonance Spectroscopic Imaging (MRSI) is a valuable tool for studying metabolic activities in the human body, but the current applications are limited to low spatial resolutions. The existing deep learning-based MRSI super-resolution methods require training a separate network for each upscaling factor, which is time-consuming and memory inefficient. We tackle this multi-scale super-resolution problem using a Filter Scaling strategy that modulates the convolution filters based on the upscaling factor, such that a single network can be used for various upscaling factors. Observing that each metabolite has distinct spatial characteristics, we also modulate the network based on the specific metabolite. Furthermore, our network is conditioned on the weight of adversarial loss so that the perceptual sharpness of the super-resolved metabolic maps can be adjusted within a single network. We incorporate these network conditionings using a novel Multi-Conditional Module. The experiments were carried out on a 1H-MRSI dataset from 15 high-grade glioma patients. Results indicate that the proposed network achieves the best performance among several multi-scale super-resolution methods and can provide super-resolved metabolic maps with adjustable sharpness.

CVApr 17, 2023
Predicting dynamic, motion-related changes in B0 field in the brain at a 7 T MRI using a subject-specific fine-tuned U-net

Stanislav Motyka, Paul Weiser, Beata Bachrata et al.

Subject movement during the magnetic resonance examination is inevitable and causes not only image artefacts but also deteriorates the homogeneity of the main magnetic field (B0), which is a prerequisite for high quality data. Thus, characterization of changes to B0, e.g. induced by patient movement, is important for MR applications that are prone to B0 inhomogeneities. We propose a deep learning based method to predict such changes within the brain from the change of the head position to facilitate retrospective or even real-time correction. A 3D U-net was trained on in vivo brain 7T MRI data. The input consisted of B0 maps and anatomical images at an initial position, and anatomical images at a different head position (obtained by applying a rigid-body transformation on the initial anatomical image). The output consisted of B0 maps at the new head positions. We further fine-tuned the network weights to each subject by measuring a limited number of head positions of the given subject, and trained the U-net with these data. Our approach was compared to established dynamic B0 field mapping via interleaved navigators, which suffer from limited spatial resolution and the need for undesirable sequence modifications. Qualitative and quantitative comparison showed similar performance between an interleaved navigator-equivalent method and proposed method. We therefore conclude that it is feasible to predict B0 maps from rigid subject movement and, when combined with external tracking hardware, this information could be used to improve the quality of magnetic resonance acquisitions without the use of navigators.

CVMar 25, 2025
Improved tissue sodium concentration quantification in breast cancer by reducing partial volume effects: a preliminary study

Olgica Zaric, Carmen Leser, Vladimir Juras et al.

Introduction: In sodium (23Na) magnetic resonance imaging (MRI), partial volume effects (PVE) are one of the most common causes of errors in the in vivo quantification of tissue sodium concentration (TSC). Advanced image reconstruction algorithms, such as compressed sensing (CS), have the potential to reduce PVE. Therefore, we investigated the feasibility of using CS-based methods to improve image quality and TSC quantification accuracy in patients with breast cancer. Subjects and methods: In this study, three healthy participants and 12 female participants with breast cancer were examined on a 7T MRI scanner. 23Na-MRI images were reconstructed using weighted total variation (wTV), directional total variation (dTV), anatomically guided total variation (AG-TV) and adaptive combine (ADC) methods. The consistency of tumor volume delineations based on sodium data was assessed using the Dice score, and TSC quantification was performed for various image reconstruction methods. Pearsons correlation coefficients were calculated to assess the relationships between wTV, dTV, AG-TV, and ADC values. Results: All methods provided breast MRI images with well-preserved sodium signal and tissue structures. The mean Dice scores for wTV, dTV, and AG-TV were 65%, 72%, and 75%, respectively. Average TSC values in breast tumors were 61.0, 72.0, 73.0, and 88.0 mmol/L for wTV, dTV, AG-TV, and ADC, respectively. A strong negative correlation was observed between wTV and dTV (r = -0.78, 95% CI [-0.94, -0.31], p = 0.0076) and a strong positive correlation between dTV and AG-TV (r = 0.71, 95% CI [0.16, 0.92], p = 0.0207) was found. Conclusion: The results of this study showed that differences in tumor appearance and TSC estimations may depend on the type of image reconstruction and the parameters used. This is most likely due to differences in their ability to reduce PVE.

IVJan 23, 2025
Variational U-Net with Local Alignment for Joint Tumor Extraction and Registration (VALOR-Net) of Breast MRI Data Acquired at Two Different Field Strengths

Muhammad Shahkar Khan, Haider Ali, Laura Villazan Garcia et al.

Background: Multiparametric breast MRI data might improve tumor diagnostics, characterization, and treatment planning. Accurate alignment and delineation of images acquired at different field strengths such as 3T and 7T, remain challenging research tasks. Purpose: To address alignment challenges and enable consistent tumor segmentation across different MRI field strengths. Study type: Retrospective. Subjects: Nine female subjects with breast tumors were involved: six histologically proven invasive ductal carcinomas (IDC) and three fibroadenomas. Field strength/sequence: Imaging was performed at 3T and 7T scanners using post-contrast T1-weighted three-dimensional time-resolved angiography with stochastic trajectories (TWIST) sequence. Assessments: The method's performance for joint image registration and tumor segmentation was evaluated using several quantitative metrics, including signal-to-noise ratio (PSNR), structural similarity index (SSIM), normalized cross-correlation (NCC), Dice coefficient, F1 score, and relative sum of squared differences (rel SSD). Statistical tests: The Pearson correlation coefficient was used to test the relationship between the registration and segmentation metrics. Results: When calculated for each subject individually, the PSNR was in a range from 27.5 to 34.5 dB, and the SSIM was from 82.6 to 92.8%. The model achieved an NCC from 96.4 to 99.3% and a Dice coefficient of 62.9 to 95.3%. The F1 score was between 55.4 and 93.2% and the rel SSD was in the range of 2.0 and 7.5%. The segmentation metrics Dice and F1 Score are highly correlated (0.995), while a moderate correlation between NCC and SSIM (0.681) was found for registration. Data conclusion: Initial results demonstrate that the proposed method may be feasible in providing joint tumor segmentation and registration of MRI data acquired at different field strengths.