0.5CLNov 28, 2023
General-Purpose vs. Domain-Adapted Large Language Models for Extraction of Structured Data from Chest Radiology ReportsAli H. Dhanaliwala, Rikhiya Ghosh, Sanjeev Kumar Karn et al.
Radiologists produce unstructured data that can be valuable for clinical care when consumed by information systems. However, variability in style limits usage. Study compares system using domain-adapted language model (RadLing) and general-purpose LLM (GPT-4) in extracting relevant features from chest radiology reports and standardizing them to common data elements (CDEs). Three radiologists annotated a retrospective dataset of 1399 chest XR reports (900 training, 499 test) and mapped to 44 pre-selected relevant CDEs. GPT-4 system was prompted with report, feature set, value set, and dynamic few-shots to extract values and map to CDEs. Output key:value pairs were compared to reference standard at both stages and an identical match was considered TP. F1 score for extraction was 97% for RadLing-based system and 78% for GPT-4 system. F1 score for mapping was 98% for RadLing and 94% for GPT-4; difference was statistically significant (P<.001). RadLing's domain-adapted embeddings were better in feature extraction and its light-weight mapper had better f1 score in CDE assignment. RadLing system also demonstrated higher capabilities in differentiating between absent (99% vs 64%) and unspecified (99% vs 89%). RadLing system's domain-adapted embeddings helped improve performance of GPT-4 system to 92% by giving more relevant few-shot prompts. RadLing system offers operational advantages including local deployment and reduced runtime costs.
1.8CVAug 8, 2019
Image-based marker tracking and registration for intraoperative 3D image-guided interventions using augmented realityAndong Cao, Ali Dhanaliwala, Jianbo Shi et al.
Augmented reality has the potential to improve operating room workflow by allowing physicians to "see" inside a patient through the projection of imaging directly onto the surgical field. For this to be useful the acquired imaging must be quickly and accurately registered with patient and the registration must be maintained. Here we describe a method for projecting a CT scan with Microsoft Hololens and then aligning that projection to a set of fiduciary markers. Radio-opaque stickers with unique QR-codes are placed on an object prior to acquiring a CT scan. The location of the markers in the CT scan are extracted and the CT scan is converted into a 3D surface object. The 3D object is then projected using the Hololens onto a table on which the same markers are placed. We designed an algorithm that aligns the markers on the 3D object with the markers on the table. To extract the markers and convert the CT into a 3D object took less than 5 seconds. To align three markers, it took $0.9 \pm 0.2$ seconds to achieve an accuracy of $5 \pm 2$ mm. These findings show that it is feasible to use a combined radio-opaque optical marker, placed on a patient prior to a CT scan, to subsequently align the acquired CT scan with the patient.