Juan M. Verde

h-index18
2papers
1,029citations

2 Papers

6.6IVMar 8, 2022
Live Laparoscopic Video Retrieval with Compressed Uncertainty

Tong Yu, Pietro Mascagni, Juan Verde et al.

Searching through large volumes of medical data to retrieve relevant information is a challenging yet crucial task for clinical care. However the primitive and most common approach to retrieval, involving text in the form of keywords, is severely limited when dealing with complex media formats. Content-based retrieval offers a way to overcome this limitation, by using rich media as the query itself. Surgical video-to-video retrieval in particular is a new and largely unexplored research problem with high clinical value, especially in the real-time case: using real-time video hashing, search can be achieved directly inside of the operating room. Indeed, the process of hashing converts large data entries into compact binary arrays or hashes, enabling large-scale search operations at a very fast rate. However, due to fluctuations over the course of a video, not all bits in a given hash are equally reliable. In this work, we propose a method capable of mitigating this uncertainty while maintaining a light computational footprint. We present superior retrieval results (3-4 % top 10 mean average precision) on a multi-task evaluation protocol for surgery, using cholecystectomy phases, bypass phases, and coming from an entirely new dataset introduced here, critical events across six different surgery types. Success on this multi-task benchmark shows the generalizability of our approach for surgical video retrieval.

3.6CVAug 28, 2025
Optimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction

Karl-Philippe Beaudet, Sidaty El Hadramy, Philippe C Cattin et al.

Intraoperative ultrasound images are inherently challenging to interpret in liver surgery due to the limited field of view and complex anatomical structures. Bridging the gap between preoperative and intraoperative data is crucial for effective surgical guidance. 3D IntraVascular UltraSound (IVUS) offers a potential solution by enabling the reconstruction of the entire organ, which facilitates registration between preoperative computed tomography (CT) scans and intraoperative IVUS images. In this work, we propose an optimization-based calibration method using a 3D-printed phantom for accurate 3D Intravascular Ultrasound volume reconstruction. Our approach ensures precise alignment of tracked IVUS data with preoperative CT images, improving intraoperative navigation. We validated our method using in vivo swine liver images, achieving a calibration error from 0.88 to 1.80 mm and a registration error from 3.40 to 5.71 mm between the 3D IVUS data and the corresponding CT scan. Our method provides a reliable and accurate means of calibration and volume reconstruction. It can be used to register intraoperative ultrasound images with preoperative CT images in the context of liver surgery, and enhance intraoperative guidance.