This study addresses critical gaps in automated lymphoma segmentation from PET/CT images, focusing on issues often overlooked in existing literature. While deep learning has been applied for lymphoma lesion segmentation, few studies incorporate out-of-distribution testing, raising concerns about model generalizability across diverse imaging conditions and patient populations. We highlight the need to compare model performance with expert human annotators, including intra- and inter-observer variability, to understand task difficulty better. Most approaches focus on overall segmentation accuracy but overlook lesion-specific measures important for precise lesion detection and disease quantification. To address these gaps, we propose a clinically relevant framework for evaluating deep segmentation networks. Using this lesion measure-specific evaluation, we assess the performance of four deep networks (ResUNet, SegResNet, DynUNet, and SwinUNETR) across 611 cases from multi-institutional datasets, covering various lymphoma subtypes and lesion characteristics. Beyond standard metrics like the Dice similarity coefficient, we evaluate clinical lesion measures and their prediction errors. We also introduce detection criteria for lesion localization and propose a new detection Criterion 3 based on metabolic characteristics. We show that networks perform better on large, intense lesions with higher metabolic activity. Finally, we compare network performance to physicians via intra- and inter-observer variability analyses, demonstrating that network errors closely resemble those made by experts, i.e., the small and faint lesions remain challenging for both humans and networks. This study aims to improve automated lesion segmentation's clinical relevance, supporting better treatment decisions for lymphoma patients. The code is available at: https://github.com/microsoft/lymphoma-segmentation-dnn.
Maziar Sabouri, Shadab Ahamed, Azin Asadzadeh et al.
The objective of this study was to develop an automated pipeline that enhances thyroid disease classification using thyroid scintigraphy images, aiming to decrease assessment time and increase diagnostic accuracy. Anterior thyroid scintigraphy images from 2,643 patients were collected and categorized into diffuse goiter (DG), multinodal goiter (MNG), and thyroiditis (TH) based on clinical reports, and then segmented by an expert. A ResUNet model was trained to perform auto-segmentation. Radiomic features were extracted from both physician (scenario 1) and ResUNet segmentations (scenario 2), followed by omitting highly correlated features using Spearman's correlation, and feature selection using Recursive Feature Elimination (RFE) with XGBoost as the core. All models were trained under leave-one-center-out cross-validation (LOCOCV) scheme, where nine instances of algorithms were iteratively trained and validated on data from eight centers and tested on the ninth for both scenarios separately. Segmentation performance was assessed using the Dice similarity coefficient (DSC), while classification performance was assessed using metrics, such as precision, recall, F1-score, accuracy, area under the Receiver Operating Characteristic (ROC AUC), and area under the precision-recall curve (PRC AUC). ResUNet achieved DSC values of 0.84$\pm$0.03, 0.71$\pm$0.06, and 0.86$\pm$0.02 for MNG, TH, and DG, respectively. Classification in scenario 1 achieved an accuracy of 0.76$\pm$0.04 and a ROC AUC of 0.92$\pm$0.02 while in scenario 2, classification yielded an accuracy of 0.74$\pm$0.05 and a ROC AUC of 0.90$\pm$0.02. The automated pipeline demonstrated comparable performance to physician segmentations on several classification metrics across different classes, effectively reducing assessment time while maintaining high diagnostic accuracy. Code available at: https://github.com/ahxmeds/thyroidiomics.git.
Amirhosein Toosi, Sara Harsini, François Bénard et al.
Prostate specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) imaging provides a tremendously exciting frontier in visualization of prostate cancer (PCa) metastatic lesions. However, accurate segmentation of metastatic lesions is challenging due to low signal-to-noise ratios and variable sizes, shapes, and locations of the lesions. This study proposes a novel approach for automated segmentation of metastatic lesions in PSMA PET/CT 3D volumetric images using 2D denoising diffusion probabilistic models (DDPMs). Instead of 2D trans-axial slices or 3D volumes, the proposed approach segments the lesions on generated multi-angle maximum intensity projections (MA-MIPs) of the PSMA PET images, then obtains the final 3D segmentation masks from 3D ordered subset expectation maximization (OSEM) reconstruction of 2D MA-MIPs segmentations. Our proposed method achieved superior performance compared to state-of-the-art 3D segmentation approaches in terms of accuracy and robustness in detecting and segmenting small metastatic PCa lesions. The proposed method has significant potential as a tool for quantitative analysis of metastatic burden in PCa patients.
Shadab Ahamed, Natalia Dubljevic, Ingrid Bloise et al.
Accurate detection and segmentation of diffuse large B-cell lymphoma (DLBCL) from PET images has important implications for estimation of total metabolic tumor volume, radiomics analysis, surgical intervention and radiotherapy. Manual segmentation of tumors in whole-body PET images is time-consuming, labor-intensive and operator-dependent. In this work, we develop and validate a fast and efficient three-step cascaded deep learning model for automated detection and segmentation of DLBCL tumors from PET images. As compared to a single end-to-end network for segmentation of tumors in whole-body PET images, our three-step model is more effective (improves 3D Dice score from 58.9% to 78.1%) since each of its specialized modules, namely the slice classifier, the tumor detector and the tumor segmentor, can be trained independently to a high degree of skill to carry out a specific task, rather than a single network with suboptimal performance on overall segmentation.
Automated slice classification is clinically relevant since it can be incorporated into medical image segmentation workflows as a preprocessing step that would flag slices with a higher probability of containing tumors, thereby directing physicians attention to the important slices. In this work, we train a ResNet-18 network to classify axial slices of lymphoma PET/CT images (collected from two institutions) depending on whether the slice intercepted a tumor (positive slice) in the 3D image or if the slice did not (negative slice). Various instances of the network were trained on 2D axial datasets created in different ways: (i) slice-level split and (ii) patient-level split; inputs of different types were used: (i) only PET slices and (ii) concatenated PET and CT slices; and different training strategies were employed: (i) center-aware (CAW) and (ii) center-agnostic (CAG). Model performances were compared using the area under the receiver operating characteristic curve (AUROC) and the area under the precision-recall curve (AUPRC), and various binary classification metrics. We observe and describe a performance overestimation in the case of slice-level split as compared to the patient-level split training. The model trained using patient-level split data with the network input containing only PET slices in the CAG training regime was the best performing/generalizing model on a majority of metrics. Our models were additionally more closely compared using the sensitivity metric on the positive slices from their respective test sets.
Mohammad R. Salmanpour, Sonya Falahati, Amir Hossein Pouria et al.
Lung cancer remains the leading cause of cancer mortality, with CT imaging central to screening, prognosis, and treatment. Manual segmentation is variable and time-intensive, while deep learning (DL) offers automation but faces barriers to clinical adoption. Guided by the Knowledge-to-Action framework, this study develops a clinician-in-the-loop DL pipeline to enhance reproducibility, prognostic accuracy, and clinical trust. Multi-center CT data from 999 patients across 12 public datasets were analyzed using five DL models (3D Attention U-Net, ResUNet, VNet, ReconNet, SAM-Med3D), benchmarked against expert contours on whole and click-point cropped images. Segmentation reproducibility was assessed using 497 PySERA-extracted radiomic features via Spearman correlation, ICC, Wilcoxon tests, and MANOVA, while prognostic modeling compared supervised (SL) and semi-supervised learning (SSL) across 38 dimensionality reduction strategies and 24 classifiers. Six physicians qualitatively evaluated masks across seven domains, including clinical meaningfulness, boundary quality, prognostic value, trust, and workflow integration. VNet achieved the best performance (Dice = 0.83, IoU = 0.71), radiomic stability (mean correlation = 0.76, ICC = 0.65), and predictive accuracy under SSL (accuracy = 0.88, F1 = 0.83). SSL consistently outperformed SL across models. Radiologists favored VNet for peritumoral representation and smoother boundaries, preferring AI-generated initial masks for refinement rather than replacement. These results demonstrate that integrating VNet with SSL yields accurate, reproducible, and clinically trusted CT-based lung cancer prognosis, highlighting a feasible path toward physician-centered AI translation.